To develop structural modifications of dNTPs that are compatible with Taq DNA polymerase activity, we synthesized eight dUTP derivatives conjugated with Cy3 or Cy5 dye analogues that differed in charge and charge distribution throughout the fluorophore. These dUTP derivatives and commercial Cy3− and Cy5-dUTP were studied in Taq polymerase-dependent polymerase chain reactions (PCRs) and in primer extension reactions using model templates containing one, two and three adjacent adenine nucleotides. The relative amounts of amplified DNA and the kinetic parameters Km and Vmax characterizing the incorporation of labelled dUMPs have been estimated using fluorescence measurements and analysed. The dUTPs labelled with electroneutral zwitterionic analogues of Cy3 or Cy5 fluorophores were used by Taq polymerase approximately one order of magnitude more effectively than the dUTPs labelled with negatively charged analogues of Cy3 or Cy5. The nucleotidyl transferase activity of Taq polymerase was also observed and resulted in the addition of dUMPs labelled with electroneutral or positively charged fluorophores to the 3′ ends of DNA. The introduction of mutually compensating charges into fluorophores or other functional groups conjugated to dNTPs can be considered a basis for the creation of PCR-compatible modified nucleoside triphosphates.
The approach based on molecular modeling was developed to study dNTP derivatives characterized by new polymerase-specific properties. For this purpose, the relative efficiency of PCR amplification with modified dUTPs was studied using Taq, Tth, Pfu, Vent, Deep Vent, Vent (exo-), and Deep Vent (exo-) DNA polymerases. The efficiency of PCR amplification with modified dUTPs was compared with the results of molecular modeling using the known 3D structures of KlenTaq polymerase–DNA–dNTP complexes. The dUTPs were C5-modified with bulky functional groups (the Cy5 dye analogs) or lighter aromatic groups. Comparing the experimental data and the results of molecular modeling revealed the decrease in PCR efficiency in the presence of modified dUTPs with an increase in the number of non-covalent bonds between the substituents and the DNA polymerase (about 15% decrease per one extra non-covalent bond). Generalization of the revealed patterns to all the studied polymerases of the A and B families is discussed herein. The number of non-covalent bonds between the substituents and polymerase amino acid residues is proposed to be a potentially variable parameter for regulating enzyme activity.
The development of rapid analysis of human serum for the presence of allergen-specific Immunoglobulin E (IgE) is currently important. Consequently, we developed two types of three-dimensional (3D) protein biochips. The first one is a 3D hydrogel biochip containing hydrogel droplets with protein molecules (allergens, immunoglobulins and others). These droplets are disposed on elements consisting of short polymer brushes grafting from a surface of polybutylene terephthalate polymer. The immobilization of proteins was induced by short-wave ultraviolet (UV) radiation. On such a biochip, the kinetics of allergen–sIgE complex formation reached 60% of saturation for 6 h. Also, we developed a 3D brush microchip containing on the surface of a polyethylene terephthalate polymer the brush elements with protein molecules covalently immobilized by opening oxirane cycles by amino and thiol nucleophilic groups contained in proteins. In the case of the 3D brush microchip, the kinetics of allergen–sIgE complex formation reached 100% of saturation for 3 h, and fluorescent signals were 2–3 times higher than those of the 3D hydrogel biochip for some allergens. Thus, the comparative analysis revealed that 3D brush biochips are more useful for further studies of protein–protein interaction than 3D hydrogel ones.
The development of rapid analysis of human serum for the presence of allergen-specific IgE is currently important. Consequently, we developed two types of 3D protein biochips. The first one is a 3D hydrogel biochip containing hydrogel droplets with protein molecules (allergens, immunoglobulins and others). These droplets are disposed on elements consisting of short polymer brushes grafting from a surface of polybutylene terephthalate polymer. The immobilization of proteins was induced by short-wave UV radiation. On such a biochip, the kinetics of allergen-sIgE complex formation reached 70% of saturation for 6 hours. Also we developed a 3D brush microchip containing on the surface of a polyethylene terephthalate polymer the brush elements with protein molecules covalently immobilized by opening oxirane cycles by amino and thiol nucleophilic groups contained in proteins. In the case of 3D brush microchip the kinetics of allergen-sIgE complex formation reached 100% of saturation for 3 hours, and fluorescent signals were 2-3 times higher than those of the 3D hydrogel biochip. Thus, the comparative analysis revealed that 3D brush biochips are more useful for further studies of protein-protein interactions than 3D hydrogel ones.
A global increase in allergic diseases is being observed worldwide, characterized not only by an increasing incidence but also by increasing severity. In recent decades, allergic diseases have become one of the most significant global challenges for healthcare systems and society. This is due to three key trends: high prevalence (allergies rank third globally after cardiovascular and oncological pathologies, and in some regions, they are the leading cause of disease), a rapidly increasing incidence (doubling every ten years), and increasing severity. Despite medical advances, more severe forms of allergic diseases lead to increased cases of temporary disability and permanent disability, which reduces patients’ quality of life. The Russian Federation faces a similar situation. Since most allergic diseases are caused by immediate reactions, timely and accurate clinical laboratory diagnostics are key to their effective treatment. Modern allergy diagnostics offer a wide range of effective methods that allow for a more precise diagnosis for each individual patient and predict the success of treatment. Allergen‑specific immunoglobulin E (sIgE) is a key player in immediate allergic reactions. Its detection underlies many diagnostic procedures. Testing is performed for both individual allergens of various types and for allergen complexes (panels). The results are presented as both the sIgE concentration and the allergic reaction class. This review examines the comparison of sIgE test results using test kits from various manufacturers used for clinical laboratory diagnosis of immediate allergic reactions in the Russian Federation.