Deep learning has been widely used in phase unwrapping. However, owing to the noise of the wrapped phase, errors in wrap count prediction and phase calculation can occur, making it challenging to achieve high measurement accuracy under high-noise conditions. To address this issue, a three-stage multi-task phase unwrapping method was proposed. The phase retrieval was divided into three training stages: wrapped phase denoising, wrap count prediction, and unwrapped phase error compensation. In the first stage, a noise preprocessing module was trained to reduce noise interference, thereby improving the accuracy of the wrap count prediction and phase calculation. The second stage involved training the wrap count prediction module. A residual compensation module was added to correct the errors from the denoising results generated in the first stage. Finally, in the third stage, the phase error compensation module was trained to correct errors in the unwrapped phase calculated in the second stage. Additionally, a convolution-based multi-scale spatial attention module was proposed, which effectively reduces the interference of spatially inconsistent noise and can be applied to a convolutional neural network. The principles of the multi-task phase unwrapping method based on a three-stage training strategy were first introduced. Subsequently, the framework and training strategies for each stage were presented. Finally, the method was tested using simulated data with varying noise levels. It was compared with TIE, iterative TIE, the least squares phase unwrapping method, UNet, phaseNet2.0, and DeepLabV3 + with a phase correction operation, demonstrating the noise robustness and phase retrieval accuracy of the proposed method.
We propose a novel, to the best of our knowledge, single-shot quantitative phase imaging (QPI) technique with the phase modulation of a liquid crystal spatial light modulator (LC-SLM) under white light illumination. By studying the phase modulation characteristics of an LC-SLM under white light illumination, images captured at different wavelengths are equivalent to those captured at different defocus distances when loading a Fresnel lens pattern on the LC-SLM. Consequently, a color camera is able to simultaneously acquire multi-intensity images at different defocus distances. Finally, the phase is retrieved from a single-shot color image using the transport of intensity equation. To demonstrate the flexibility and accuracy of our method, a photoetched phase object and human red blood cells are quantitatively measured. An investigation of living yeast cells is conducted to verify the dynamic measurement capability. The proposed method provides a simple, efficient, and flexible means to accomplish real-time high-resolution quantitative phase imaging without sacrificing the field of view (FOV), which can be further integrated into a conventional microscope to achieve real-time microscopic QPI.
This paper proposes a flexible and accurate dynamic quantitative phase imaging (QPI) method using single-shot transport of intensity equation (TIE) phase retrieval achieved by division of focal plane (DoFP) polarization imaging technique. By exploiting the polarization property of the liquid crystal spatial light modulator (LC-SLM), two intensity images of different defocus distances contained in orthogonal polarization directions can be generated simultaneously. Then, with the help of the DoFP polarization imaging, these images can be captured with single exposure, enabling accurate dynamic QPI by solving the TIE. In addition, our approach gains great flexibility in defocus distance adjustment by adjusting the pattern loaded on the LC-SLM. Experiments on microlens array, phase plate, and living human gastric cancer cells demonstrate the accuracy, flexibility, and dynamic measurement performance for various objects. The proposed method provides a simple, flexible, and accurate approach for real-time QPI without sacrificing the field of view.
Label-free detection of intracellular substances for living cancer cells remains a significant hurdle in cancer pathogenesis research. Although the sensitivity of light polarization to intracellular substances has been validated, current studies are predominantly focused on tissue lesions, thus label-free detection of substances within individual living cancer cells is still a challenge. The main difficulty is to find specific detection methods along with corresponding characteristic parameters. With refractive index as an endogenous marker of substances, this study proposes a detection method of intracellular refractive index distribution (IRID) for label-free living colon cancer (LoVo) cells. Utilizing the circular depolarization decay model (CDDM) to calculate the degree of circular polarization (DOCP) modulated by the cell allows for the derivation of the IRID on the focal plane. Experiments on LoVo cells demonstrated the refractive index of single cell can be accurately and precisely measured, with precision of 10−3 refractive index units (RIU). Additionally, chromatin content during the interphases (G1, S, G2) of cell cycle was recorded at 56.5%, 64.4%, and 71.5%, respectively. A significantly finer IRID can be obtained compared to the phase measurement method. This method is promising in providing a dynamic label-free intracellular substances detection method in cancer pathogenesis studies.