Introduction: Osteochondrosis dissecans (OCD) is a disease affecting the subchondral bone and the overlying articular cartilage. The etiology is most likely a combination of biological and mechanical factors. The incidence is highest in children >12 years old and it predominantly affects the knee. In high-grade OCD lesions, free osteochondral fragments usually are refixed via titanium screws or biodegradable screws or pins. In this case, headless compression screws made from magnesium were used for refixation. Case report: A thirteen-year-old female patient with a two-year history of knee pain was diagnosed with an OCD lesion of the medial femoral condyle. After initial conservative treatment, displacement of the osteochondral fragment occurred. Refixation was performed using two headless magnesium compression screws. At the 6 months follow up, the patient was pain free, and the fragment showed progressive healing while the implants were biodegrading. Discussion: Existing implants for refixation of OCD lesions either require subsequent removal or show less stability and possible inflammatory reactions. The new generation of magnesium screws used in this case did not lead to a gas release, as described for previous magnesium implants, while maintaining stability during continuous biodegradation. Conclusions: The data available to date on magnesium implants for the treatment of OCD are promising. However, the evidence on the magnesium implants in refixation surgery of OCD lesions is still limited. Further research needs to be conducted to provide data on outcomes and possible complications.
5 August 2025 in Knee Surgery, Sports Traumatology, Arthroscopy
Purpose: The aim of this study was to quantify the contribution of the meniscofemoral ligaments (MFLs) on restraining a posterior tibial translation (PTT) in the human knee joint. Methods: Sixteen human cadaveric knee joints were tested in a robotic test setup with six degrees of freedom. Knees with no MFL, one MFL and two MFLs were included. Knee joints without MFLs were excluded from the statistical analysis regarding the influence of MFLs on PTT. The knees were tested in a displacement‐controlled protocol, which replayed the native kinematics of a force controlled test protocol with PTT at 89 N in neutral tibial rotation, PTT in 5 Nm internal rotation, PTT in 5 Nm external rotation, while constantly measuring the force. The principle of superposition was used to determine the contribution of each cut structure (in‐situ forces) to restraint of the performed movements. First, the anterior and posterior MFL (aMFL/pMFL) were randomly cut, followed by the posterior cruciate ligament (PCL). Results: Neither the aMFL, nor the pMFL showed a significant contribution to the restriction of PTT in the PCL‐intact knee neither in 0°, 30°, 60° or 90° of flexion in neutral, internal, or external rotation ( p > 0.05). The PCL showed a significant contribution to the knee joint restraining PTT in 0°, 30°, 60° and 90° flexion as well as in all rotation states (all p < 0.05). A contribution of the PCL restraining PTT of 28% ± 14% in 0° flexion, 53% ± 21% in 30° flexion, 61% ± 20% in 60° flexion and 54% ± 16% in 90° knee flexion was measured in neutral rotation. Conclusion: The MFLs do not contribute to restriction of a PTT in any flexion angle, while the PCL acts as the primary restraint against PTT from 0°–90° knee flexion. This effect was seen in neutral rotation as well as in tibial internal and external rotation. This study indicates that a dissection of the MFLs to gain access to the PCL during reconstruction surgery does not destabilise the knee. Level of Evidence: N/A.
Purpose: Recent biomechanical research suggests suture anchor (SA) refixation may be superior to conventional transosseous longitudinal (TL) repair for quadriceps tendon ruptures. This study aimed to evaluate whether a modified transosseous technique with anteriorly angled drill holes enhances primary stability compared to the aforementioned techniques. Methods: Twenty‐one human cadaveric patellae were randomly assigned to three groups ( n = 7): SA (two SAs), TL (three longitudinal transosseous drill holes) and TA (three anteriorly angled 45° transosseous drill holes). Identical suture material (Ethibond #2) and a four‐strand suture configuration were used in all groups. Prior to fixation, computed tomography (CT) scans measured bone mineral density (BMD) and cortical thickness. Biomechanical testing simulated early postoperative loading using a universal testing machine: preload (20 N for 30 s), cyclic loading (500 cycles, 20–100 N at 1 Hz) and a load‐to‐failure test (20 mm/s). As primary outcome, ultimate load to failure was recorded; secondarily, cyclic elongation and stiffness were measured. One‐way analysis of variance (ANOVA) with Bonferroni‐corrected post hoc t tests was used for statistical analysis. Results: The TA group had a significantly higher ultimate load to failure than the TL group (472.7 ± 22.4 vs. 344.8 ± 108.8 N, p < 0.05). No significant differences were found between the SA group (438.9 ± 77.4 N) and the other groups. The TL group showed significantly greater cyclic elongation (6.22 ± 1.03 mm) compared to the SA group (4.42 ± 0.82 mm, p < 0.01). The TA group (5.03 ± 0.73 mm) showed no significant difference compared to either group. Stiffness did not differ significantly ( p > 0.05). Conclusion: The modified transosseous technique with anterior drill holes yields higher failure loads and less elongation than the conventional TL method, with biomechanical performance comparable to SA fixation, supporting its use as a viable alternative. Level of Evidence: N/A.