Kevin Bennett

Dr. Kevin Bennett


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2019 in American Journal of Physiology-Renal Physiology
Verified
Journal Article
Closed access
PDF file
EBEdwin J. Baldelomar
Edwin J. Baldelomar
JCJennifer R. Charlton
Jennifer R. Charlton
KDKimberly A. Deronde
Kimberly A. Deronde
KBKevin Bennett
Kevin Bennett
The development of chronic kidney disease (CKD) is associated with the loss of functional nephrons. However, there are no methods to directly measure nephron number in living subjects. Thus, there are no methods to track the early stages of progressive CKD before changes in total renal function. In this work, we used cationic ferritin-enhanced magnetic resonance imaging (CFE-MRI) to enable measurements of glomerular number ( Nglom) and apparent glomerular volume (aVglom) in vivo in healthy wild-type (WT) mice ( n = 4) and mice with oligosyndactylism (Os/+; n = 4), a model of congenital renal hypoplasia leading to nephron reduction. We validated in vivo measurements of Nglom and aVglom by high-resolution ex vivo MRI. CFE-MRI measured a mean Nglom of 12,220 ± 2,028 and 6,848 ± 1,676 (means ± SD) for WT and Os/+ mouse kidneys in vivo, respectively. Nglom measured in all mice in vivo using CFE-MRI varied by an average 15% from Nglom measured ex vivo in the same kidney (α = 0.05, P = 0.67). To confirm that CFE-MRI can also be used to track nephron endowment longitudinally, a WT mouse was imaged three times by CFE-MRI over 2 wk. Values of Nglom measured in vivo in the same kidney varied within ~3%. Values of aVglom calculated from CFE-MRI in vivo were significantly different (~15% on average, P < 0.01) from those measured ex vivo, warranting further investigation. This is the first report of direct measurements of Nglom and aVglom in healthy and diseased mice in vivo.

1 January 2022 in Journal of the American Society of Nephrology
Verified
Journal Article
Closed access
PDF file
DMDarya Morozov
Darya Morozov
NPNeda Parvin
Neda Parvin
MCMark Conaway
Mark Conaway
GOGavin Oxley
Gavin Oxley
EBEdwin J. Baldelomar
Edwin J. Baldelomar
KBKevin Bennett
Kevin Bennett
Significance Statement: Total nephron number is a potentially important marker of susceptibility to kidney disease. This work demonstrates the effect of spatial variation in glomerular density on the estimation of whole-kidney nephron number from biopsy. We show here that a single needle biopsy does not accurately reflect whole-kidney nephron number on an individual level. However, in studies with a large number of subjects or samples, needle biopsies can reveal differences in nephron number between populations. There is a need for new technologies to directly measure nephron number at an individual level. Background: Accumulating evidence supports an association between nephron number and susceptibility to kidney disease. However, it is not yet possible to directly measure nephron number in a clinical setting. Recent clinical studies have used glomerular density from a single biopsy and whole kidney cortical volume from imaging to estimate nephron number and single nephron glomerular filtration rate. However, the accuracy of these estimates from individual subjects is unknown. Furthermore, it is not clear how sample size or biopsy location may influence these estimates. These questions are critical to study design, and to the potential translation of these tools to estimate nephron number in individual subjects. Methods: We measured the variability in estimated nephron number derived from needle or virtual biopsies and cortical volume in human kidneys declined for transplantation. We performed multiple needle biopsies in the same kidney, and examined the three-dimensional spatial distribution of nephron density by magnetic resonance imaging. We determined the accuracy of a single-kidney biopsy to predict the mean nephron number estimated from multiple biopsies from the same kidney. Results: A single needle biopsy had a 15% chance and virtual biopsy had a 60% chance of being within 20% of the whole-kidney nephron number. Single needle biopsies could be used to detect differences in nephron number between large cohorts of several hundred subjects. Conclusions: The number of subjects required to accurately detect differences in nephron number between populations can be predicted on the basis of natural intrakidney variability in glomerular density. A single biopsy is insufficient to accurately predict nephron number in individual subjects.

27 January 2020 in Journal of Developmental Origins of Health and Disease
Verified
Journal Article
Closed access
PDF file
KBKevin Bennett
Kevin Bennett
EBE.J. Baldelomar
E.J. Baldelomar
DMD. Morozov
D. Morozov
RCR.L Chevalier
R.L Chevalier
JCJ.R Charlton
J.R Charlton
The mammalian kidney is a complex organ, requiring the concerted function of up to millions of nephrons. The number of nephrons is constant after nephrogenesis during development, and nephron loss over a life span can lead to susceptibility to acute or chronic kidney disease. New technologies are under development to count individual nephrons in the kidney in vivo. This review outlines these technologies and highlights their relevance to studies of human renal development and disease.

20 July 2021 in American Journal of Physiology-Renal Physiology
Verified
Journal Article
Closed access
PDF file
JCJennifer R. Charlton
Jennifer R. Charlton
YXYanzhe Xu
Yanzhe Xu
NPNeda Parvin
Neda Parvin
TWTeresa Wu
Teresa Wu
FGFei Gao
Fei Gao
KBKevin Bennett
Kevin Bennett
We report the application of cutting-edge image analysis approaches to characterize the pyramidal geometry, glomerular microstructure, and heterogeneity of the whole human kidney imaged using MRI. This work establishes a framework to improve the detection of microstructural pathology to potentially facilitate disease monitoring or transplant evaluation in the individual kidney.

23 May 2020 in The Anatomical Record
Verified
Journal Article
Closed access
PDF file
NPNeda Parvin
Neda Parvin
JCJennifer R. Charlton
Jennifer R. Charlton
EBEdwin J. Baldelomar
Edwin J. Baldelomar
JDJamal J. Derakhshan
Jamal J. Derakhshan
KBKevin Bennett
Kevin Bennett

7 December 2020 in American Journal of Physiology-Renal Physiology
Verified
Journal Article
Closed access
PDF file
EBEdwin J. Baldelomar
Edwin J. Baldelomar
DRDavid E. Reichert
David E. Reichert
KSKooresh I. Shoghi
Kooresh I. Shoghi
SBScott C. Beeman
Scott C. Beeman
JCJennifer R. Charlton
Jennifer R. Charlton
KBKevin Bennett
Kevin Bennett
Nephron number varies widely in humans. A low nephron endowment at birth or a loss of functioning nephrons is strongly linked to increased susceptibility to chronic kidney disease. In this work, we developed a contrast agent, radiolabeled cationic ferritin (RadioCF), to map functioning glomeruli in vivo in the kidney using positron emission tomography (PET). PET radiotracers can be detected in trace doses (<30 nmol), making them useful for rapid clinical translation. RadioCF is formed from cationic ferritin (CF) and with a radioisotope, Cu-64, incorporated into the ferritin core. We showed that RadioCF binds specifically to kidney glomeruli after intravenous injection in mice, whereas radiolabeled noncationic ferritin (RadioNF) and free Cu-64 do not. We then showed that RadioCF-PET can distinguish kidneys in healthy wild-type (WT) mice from kidneys in mice with oligosyndactylism (Os/+), a model of congenital hypoplasia and low nephron mass. The average standardized uptake value (SUV) measured by PET 90 min after injection was 21% higher in WT mice than in Os/+ mice, consistent with the higher glomerular density in WT mice. The difference in peak SUV from SUV at 90 min correlated with glomerular density in male mice from both WT and Os/+ cohorts ( R2 = 0.98). Finally, we used RadioCF-PET to map functioning glomeruli in a donated human kidney. SUV within the kidney correlated with glomerular number ( R2= 0.78) measured by CF-enhanced magnetic resonance imaging in the same locations. This work suggests that RadioCF-PET appears to accurately detect nephron mass and has the potential for clinical translation.