Andrea Baricci

Prof. Dr. Andrea Baricci

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2018 in Applied Energy
Verified
Journal Article
Closed access
MMM. Messaggi
M. Messaggi
PCP. Canzi
P. Canzi
RMRiccardo Mereu
Riccardo Mereu
ABAndrea Baricci
Andrea Baricci
FIF. Inzoli
F. Inzoli
MZM. Zago
M. Zago

1 May 2013 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
SGSamuele Galbiati
Samuele Galbiati
ABAndrea Baricci
Andrea Baricci
ACAndrea Casalegno
Andrea Casalegno
RMRenzo Marchesi
Renzo Marchesi

27 November 2019 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
TJThomas Jahnke
Thomas Jahnke
GFGeorg A. Futter
Georg A. Futter
ABAndrea Baricci
Andrea Baricci
CRClaudio Rabissi
Claudio Rabissi
ACAndrea Casalegno
Andrea Casalegno
The loss of electrochemical active surface area (ECSA) at the cathode is one of the main causes of performance degradation in Polymer Electrolyte Membrane Fuel Cells (PEMFCs). In order to investigate the catalyst degradation and the influence of the operating conditions we develop a multiscale degradation model which includes the formation and reduction of platinum oxides, platinum dissolution, particle growth due to Ostwald ripening, platinum ion transport through the ionomer and platinum band formation in the membrane. This degradation model is coupled with a 2D PEMFC performance model and predictions regarding ion concentration, ECSA evolution and particle growth are validated with dedicated experiments and literature data. Degradation under several AST protocols and under steady state operation are compared and discussed. The importance of a spatially resolved catalyst degradation model is conveyed by the occurrence of a depletion zone in the catalyst layer close to the membrane due to the platinum migration into the membrane. By comparing the correlation between platinum mass loss in the catalyst layer and the ECSA loss we conclude that catalyst degradation under AST conditions with nitrogen is not representative for the degradation under normal operation.

15 July 2020 in Energies
Verified
Journal Article
Open access
PDF file
Behzad NajafiBehzad Najafi
Behzad Najafi
PBPaolo Bonomi
Paolo Bonomi
ACAndrea Casalegno
Andrea Casalegno
FRFabio Rinaldi
Fabio Rinaldi
ABAndrea Baricci
Andrea Baricci
The present paper is focused on proposing and implementing a methodology for robust and rapid diagnosis of PEM fuel cells’ faults using Electrochemical Impedance Spectroscopy (EIS). Accordingly, EIS tests have been first conducted on four identical fresh PEM fuel cells along with an aged PEMFC at different current density levels and operating conditions. A label, which represents the presence of a type of fault (flooding or dehydration) or the regular operation, is then assigned to each test based on the expert knowledge employing the cell’s spectrum on the Nyquist plot. Since the time required to generate the spectrum should be minimized and considering the notable difference in the time needed for carrying out EIS tests at different frequency ranges, the frequencies have been categorized into four clusters (based on the corresponding order of magnitude: >1 kHz, >100 Hz, >10 Hz, >1 Hz). Next, for each frequency cluster and each specific current density, while utilizing a classification algorithm, a feature selection procedure is implemented in order to find the combination of EIS frequencies utilizing which results in the highest fault diagnosis accuracy and requires the lowest EIS testing time. For the case of fresh cells, employing the cluster of frequencies with f > 10 Hz, an accuracy of 98.5 % is obtained, whereas once the EIS tests from degraded cells are added to the dataset, the achieved accuracy is reduced to 89.2 % . It is also demonstrated that, while utilizing the selected pipelines, the required time for conducting the EIS test is less than one second, an advantage that facilitates real-time in-operando diagnosis of water management issues.

1 April 2020 in Journal of Power Sources
Verified
Journal Article
Closed access
MZM. Zago
M. Zago
ABAndrea Baricci
Andrea Baricci
ABA. Bisello
A. Bisello
TJT. Jahnke
T. Jahnke
HYHaoran Yu
Haoran Yu
ACA. Casalegno
A. Casalegno

1 September 2017 in Electrochimica Acta
Verified
Journal Article
Closed access
HYHaoran Yu
Haoran Yu
ABAndrea Baricci
Andrea Baricci
ABAndrea Bisello
Andrea Bisello
ACAndrea Casalegno
Andrea Casalegno
LGLaure Guetaz
Laure Guetaz
RMRadenka Maric
Radenka Maric