Bingyin Ma

Dr. Bingyin Ma

Arrival Ltd, London, City of London, UK
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2021 in Analytical Chemistry
Verified
Journal Article
Closed access
LYLihui Yang
Lihui Yang
XLXiaobo Liu
Xiaobo Liu
BYBing Yin
Bing Yin
XDXunxun Deng
Xunxun Deng
XLXiaotong Lin
Xiaotong Lin
SWShuo Wu
Shuo Wu

31 January 2022 in The Analyst
Verified
Journal Article
Closed access
PDF file
TJTingting Jiang
Tingting Jiang
BYBing Yin
Bing Yin
XLXiaobo Liu
Xiaobo Liu
LYLihui Yang
Lihui Yang
HPHongyu Pang
Hongyu Pang
SWShuo Wu
Shuo Wu
Ion sensors are attracting attention for real-time ion monitoring in biological fluids, which requires the development of sensitive, stable, flexible, robust and durable ion-selective electrodes (ISEs) and reference electrodes (REs). In this paper, a highly robust and durable ion sensor was prepared by coating polymer membranes on porous carbon electrodes. A high sensitivity of 58.6 mV per decade with a rapid response time of 0.8 s, and a negligible potential drift less than 1.4 mV h−1 were obtained simultaneously. In addition, after six washing cycles, the K+ ion sensors still have an average sensitivity of 53.2 mV per decade. Importantly, the polymer membrane permeated and packed the porous structure tightly, and thus the ion sensors presented outstanding robustness and durability. The Nernst slope of the K+ ion response fluctuated from 60.2 to 57.9 mV per decade between 0° and 60° bending angles. Repeated bending for 8000 cycles did not result in the delamination of the sensing and reference membranes or reduction of the sensitivity (57.4 mV per decade). Furthermore, five kinds of flexible reference electrodes (LEC, bare Ag, bare Ag/AgCl, PVB + NaCl on Ag/AgCl, PVC/agarose + NaCl on Ag/AgCl) were fabricated and evaluated in terms of the sensitivity for Cl− and long-term stability. Finally, the flexible K+ ion sensor was integrated with microfluidic channels and connected to a portable electrochemical workstation to realize the real-time analysis of human sweat.

15 July 2019 in Nano Letters
Verified
Journal Article
Closed access
HGHongyan Gao
Hongyan Gao
BYBing Yin
Bing Yin
SWSiyu Wu
Siyu Wu
XLXiaomeng Liu
Xiaomeng Liu
TFTianda Fu
Tianda Fu
JYJun Yao
Jun Yao

1 July 2011 in Key Engineering Materials
Verified
Journal Article
Closed access
PDF file
XQXiao Zhi Qi
Xiao Zhi Qi
ZDZong Quan Deng
Zong Quan Deng
BMBingyin Ma
Bingyin Ma
Bing LiBing Li
Bing Li
RLRongqiang Liu
Rongqiang Liu
This paper investigates the possibilities of building large deployable mechanical network based on Myard linkage, a 5R overconstrained linkage. The motion configurations of a Myard linkage is first briefly introduced, and the results show that the linkage is a good candidate for forming large spatial deployable structures which can be deployed to a planar configuration and folded to a compact bundle. Three kinds of assembly ways of Myard linkages are introduced. Afterwards, two types of large spatial deployable networks based on Myard linkages with different twist angles are developed.

13 March 2025 in Advanced Functional Materials
Verified
Journal Article
Closed access
WHWenqi Han
Wenqi Han
RNRuicheng Nie
Ruicheng Nie
BYBing Yin
Bing Yin
JZJie Zhang
Jie Zhang
SQSen Qiu
Sen Qiu
Yantao ShiYantao Shi
Yantao Shi

26 January 2024 in Analytical Chemistry
Verified
Journal Article
Closed access
YGYuan Gao
Yuan Gao
BYBing Yin
Bing Yin
XLXiaobo Liu
Xiaobo Liu
SWShuo Wu
Shuo Wu