Sergio M. Alcocer

Dr. Sergio M. Alcocer

Institute of Engineering, Universidad Nacional Autónoma de México, Mexico City, Ciudad de México, Mexico
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2004 in Natural Hazards Review
Verified
Journal Article
Closed access
RMRoberto Meli
Roberto Meli
SASergio M. Alcocer
Sergio M. Alcocer
Some of the structural earthquake-disaster mitigation programs implemented in developing countries are evaluated, with an emphasis on Latin America. Recommendations for reducing the vulnerability of engineered construction include the following: (1) promote the use of structural systems with a built-in large seismic capacity; (2) avoid the adoption among practitioners of new building technologies without a previous process of review and assimilation; (3) develop specific design and rehabilitation requirements for critical facilities; (4) implement codes of different levels of complexity; (5) improve the expertise of building officials; and (6) apply financial and tax incentives. For nonengineered buildings, recommendations include the following: (1) encourage the participation of building owners and develop specific training programs for them; (2) promote the use of structural solutions akin to the local practice; (3) encourage the participation of local universities and professional associations; (4) take advantage of periods of hyperreceptivity immediately following severe earthquakes; (5) develop small-scale pilot studies; (6) disseminate the successes attained in similar areas and conditions; (7) implement economic incentives (suitable materials at reduced prices and temporary employment for masons); and (8) link vulnerability-reduction tasks to other actions aimed at improving housing habitability and durability, and at reducing poverty.

30 October 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
SASergio M. Alcocer
Sergio M. Alcocer
LFLeonardo E. Flores
Leonardo E. Flores
JMJaime Marcelino
Jaime Marcelino
GLGustavo Lazalde
Gustavo Lazalde

7 December 2009
Verified
Conference Paper
Closed access
SBSergio F. Breña
Sergio F. Breña
SASergio M. Alcocer
Sergio M. Alcocer
Rehabilitation techniques for seismically deficient reinforced concrete elements were developed more than 20 years ago. At that time, lateral-load response of rehabilitated elements was deemed satisfactory if significant strength degradation did not occur at a target displacement demand (typically large). Large economic losses in recent earthquakes have highlighted the importance of evaluating element response at other performance levels, such as those associated with smaller displacements. In order to accurately estimate the global response of rehabilitated reinforced concrete buildings, a thorough understanding on the response of individual rehabilitated components must be developed. ASCE/SEI Standard 41-06 — Seismic Rehabilitation of Existing Buildings, provides engineers with a much needed resource to incorporate performance-based concepts in seismic rehabilitation projects. Within ASCE/SEI 41-06, guidelines to develop backbone curves for modeling typical reinforced concrete elements, and acceptance criteria of these elements based on their calculated deformation are provided. The document, however, does not explicitly include information that can be used for elements that have been rehabilitated by methods such as jacketing. A need to examine the performance of these elements using a multi-level performance perspective is therefore warranted. In this paper, a comparison of the laboratory performance of jacketed reinforced concrete columns with modeling parameters in ASCE/SEI 41-06 is presented. This information is part of ongoing activities taking place within ACI Committee 369 — Seismic Repair and Rehabilitation, that focus on an evaluation of existing guidelines for the seismic rehabilitation of concrete buildings. Existing laboratory tests found in the literature are used to compare the plastic deformation capacity of jacketed reinforced concrete columns with the corresponding modeling parameters in ASCE 41-06. The three primary types of jacketing materials that have been used to date (concrete, steel, and fiber-reinforced polymers) are included in the study. Particular attention is paid on whether plastic drifts in jacketed columns compare favorably with modeling parameters in ASCE/SEI 41-06.

10 October 2025 in Journal of Building Engineering
Verified
Journal Article
Closed access
VCVíctor D. Cruz
Víctor D. Cruz
SASergio M. Alcocer
Sergio M. Alcocer
SVSandra Vera
Sandra Vera
BCBrett Cates
Brett Cates
ÁCÁlvaro Celestino
Álvaro Celestino

1 January 2025
Verified
Book
Closed access
SASergio M. Alcocer
Sergio M. Alcocer
JGJorge Aguirre González
Jorge Aguirre González
JRJorge A. Ávila Rodríguez
Jorge A. Ávila Rodríguez
EBEduardo Botero-Jaramillo
Eduardo Botero-Jaramillo
MCMarcos M Chávez
Marcos M Chávez
ESEfraín Ovando Shelley
Efraín Ovando Shelley
El 6 de febrero de 2023, a las 4:17 h tiempo local de Turquía, ocurrió el sismo Pazarcik-Kahramanmaras de magnitud Mw 7.7 (AFAD) con profundidad focal de 8.6 km. Ese mismo día, a las 13:24 h tiempo local, ocurrió el sismo Ebistan-Kahramanmaras, de magnitud Mw 7.6 (AFAD). Las aceleraciones máximas registradas sobrepasaron los 1,000 gal en seis del total de 850 estaciones instaladas y, en varias estaciones, los espectros de respuesta superaron los niveles de diseño del reglamento vigente, pero hubo muchas en que no fue así. El reglamento en Turquía es de aplicación nacional. En lo que corresponde a los aspectos geotécnicos, los daños asociados a la licuación de arenas fueron los más ostensibles, principalmente en las regiones de Hatay-İskenderun, Hatay-Paşaköy, Adıyaman-Gölbaşı y Adıyaman-Türkoğlu. La bondad de las cimentaciones profundas con pilas o pilotes para evitar o mitigar considerablemente los efectos nocivos de la licuación de arenas fue evidente, al igual que el uso de aisladores sísmicos, según se constató en al menos dos importantes hospitales. Los sismos de interés volvieron a manifestar las ventajas de cumplir con los reglamentos y normas de diseño para proteger la vida y el patrimonio de las personas. Los colapsos y daños en los edificios evidenciaron errores de diseño y detallado del refuerzo, longitudinal y transversal, consistentes con un comportamiento frágil, claramente indeseable en zonas sísmicas. Los materiales usados eran claramente de baja resistencia y con características inadecuadas para resistir sismos. La calidad de la ejecución fue notoriamente deficiente. El excelente comportamiento de hospitales aislados sísmicamente sugiere establecer una política de diseño de nuevos hospitales y la rehabilitación de los existentes que contemple a los dispositivos de control de la respuesta como tecnologías obligatorias. Es conveniente que el Instituto de Ingeniería establezca lazos formales de colaboración con colegas turcos en diversos campos, incluidos la ingeniería sismológica, ingeniería geotécnica, ingeniería estructural y mitigación del riesgo sísmico

1 June 2023
Verified
Book Chapter
Closed access
PDF file
JAJorfran Alcaraz-Vázquez
Jorfran Alcaraz-Vázquez
JAJosé E. Andrade
José E. Andrade
AGAracely Gomez-Diaz
Aracely Gomez-Diaz
VGVanessa Y. González
Vanessa Y. González
SPSara Palma
Sara Palma
SASergio M. Alcocer
Sergio M. Alcocer