Emerging infectious disease threats are becoming more frequent due to various social, political, and geographical pressures, including increased human–animal contact, global trade, transportation, and changing climate conditions. Since blood products for transfusion are derived from donated blood from the general population, emerging agents spread by blood contact or the transfusion of blood products are also a potential risk. Blood transfusions are essential in treating patients with anemia, blood loss, and other medical conditions. However, these lifesaving procedures can contribute to infectious disease transmission, particularly to vulnerable populations. New methods have been implemented on a global basis for the prevention of transfusion transmissions via plasma, platelets, and whole blood products. Implementing proactive pathogen reduction methods may reduce the likelihood of disease transmission via blood transfusions, even for newly emerging agents whose transmissibility and susceptibility are still being evaluated as they emerge. In this review, we consider the Mirasol PRT system for blood safety, which is based on a photochemical method involving riboflavin and UV light. We provide examples of how emerging threats, such as Ebola, SARS-CoV-2, hepatitis E, mpox and other agents, have been evaluated in real time regarding effectiveness of this method in reducing the likelihood of disease transmission via transfusions.
1 October 2021 in Transfusion and Apheresis Science
In 2014-2015, the Luxembourg Red Cross (LRC) implemented a fully automated system (FAS) able to process 4 whole blood units simultaneously, and a pathogen reduction technology (PRT) based on riboflavin and ultraviolet light to improve safety of platelet concentrates (PCs). In this observational study, the impact of both technologies to enable this centralised blood transfusion centre to provide safe and timely blood components supply for the whole country was analysed. Standard quality control parameters for blood components, productivity and safety were compared from data collected with the conventional semi- automated buffy coat method and with FAS/PRT. The FAS decreased processing time when compared with the buffy coat method and facilitated the daily routine at the LRC. Red blood cell concentrates, plasma units and PCs prepared with both methods were conform to the European Directorate for the Quality of Medicines & HealthCare specifications. PCs prepared by FAS showed high yields, with decreased variability when the device-related software (T-Pool Select) was used. PRT had minimal impact on platelet yields and product quality and induced no increase in transfusion reaction notifications. The FAS and PRT transformed the daily routine of blood component manufacture by allowing increased productivity and efficiency, notwithstanding resource containment and without impacting quality, yet promoting safety.
Background and ObjectivesImplementation of automated steps in preparing blood components for transfusion from whole blood collections has produced improvements in multiple fields. The aim of this review is to summarize data from existing literature related to automation of whole blood processing systems. Materials and MethodsWe searched MEDLINE for studies comparing semi-automated and fully automated whole blood processing systems published before 20 July 2021. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Additionally, we performed a manual search. ResultsWe identified 500 studies, of which 459 (92%) did not meet the eligibility criteria, and finally 17 studies were included in the analysis. Manual search included six additional studies. Publication year ranged from 2004 to 2021. Automation reduced the run-time (from 92 to 76 min), improved recovery of haemoglobin in red cell concentrates (RCCs) and resulted in higher red blood cell and platelet yields. Automation also reduced discard rates due to whole blood bag ruptures (1.2%-0.1%), low volume of RCCs (<200 ml; 0.5%-0.03%) and haemolytic plasma (2.1%-0.6%). Automation could reduce the number of full-time equivalent (FTE) operators or maintain the number of FTE operators while performing additional procedures, and it reduced to 1.13 m(2) the space required for the device. ConclusionAutomation of whole blood processing resulted in continued improvements in productivity, product quality and technical features. However, too few publications are available to reach strong conclusions. Therefore, it is necessary to expand the scientific knowledge in this field.