IONETE Catalin Cosmin

Dr. IONETE Catalin Cosmin


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Marcel NicolaMarcel Nicola
Marcel Nicola
Claudiu-Ionel NICOLAClaudiu-Ionel NICOLA
Claudiu-Ionel NICOLA
DSDan Selisteanu
Dan Selisteanu
ICIONETE Catalin Cosmin
IONETE Catalin Cosmin
GSGHEORGHE-DORIN SENDRESCU
GHEORGHE-DORIN SENDRESCU
This article starts from the premise that one of the global control strategies of the Permanent Magnet Synchronous Motor (PMSM), namely the Direct Torque Control (DTC) control strategy, is characterized by the fact that the internal flux and torque control loop usually uses ON–OFF controllers with hysteresis, which offer easy implementation and very short response times, but the oscillations introduced by them must be cancelled by the external speed loop controller. Typically, this is a PI speed controller, whose performance is good around global operating points and for relatively small variations in external parameters and disturbances, caused in particular by load torque variation. Exploiting the advantages of the DTC strategy, this article presents a way to improve the performance of the sensorless control system (SCS) of the PMSM using the Proportional Integrator (PI), PI Equilibrium Optimizer Algorithm (EOA), Fractional Order (FO) PI, Tilt Integral Derivative (TID) and FO Lead–Lag under constant flux conditions. Sliding Mode Control (SMC) and FOSMC are proposed under conditions where the flux is variable. The performance indicators of the control system are the usual ones: response time, settling time, overshoot, steady-state error and speed ripple, plus another one given by the fractal dimension (FD) of the PMSM rotor speed signal, and the hypothesis that the FD of the controlled signal is higher when the control system performs better is verified. The article also presents the basic equations of the PMSM, based on which the synthesis of integer and fractional controllers, the synthesis of an observer for estimating the PMSM rotor speed, electromagnetic torque and stator flux are presented. The comparison of the performance for the proposed control systems and the demonstration of the parametric robustness are performed by numerical simulations in Matlab/Simulink using Simscape Electrical and Fractional-Order Modelling and Control (FOMCON). Real-time control based on an embedded system using a TMS320F28379D controller demonstrates the good performance of the PMSM-SCS based on the DTC strategy in a complete Hardware-In-the-Loop (HIL) implementation.

21 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Marcel NicolaMarcel Nicola
Marcel Nicola
Claudiu-Ionel NICOLAClaudiu-Ionel NICOLA
Claudiu-Ionel NICOLA
ICIONETE Catalin Cosmin
IONETE Catalin Cosmin
GSGHEORGHE-DORIN SENDRESCU
GHEORGHE-DORIN SENDRESCU
MRMonica Roman
Monica Roman
This paper summarizes a robust controller based on the fact that, in the operation of a permanent magnet synchronous motor (PMSM), a number of disturbance factors naturally occur, among which both changes in internal parameters (e.g., stator resistance Rs and combined inertia of rotor and load J) and changes in load torque TL can be mentioned. In this way, the performance of the control system can be maintained over a relatively wide range of variation in the types of parameters mentioned above. It also presents the synthesis of robust control, the implementation in MATLAB/Simulink, and an improved version using a reinforcement learning twin-delayed deep deterministic policy gradient (RL-TD3) agent, working in tandem with the robust controller to achieve superior performance of the PMSM sensored control system. The comparison of the proposed control systems, in the case of sensored control versus the classical field oriented control (FOC) structure, based on classical PI-type controllers, is made both in terms of the usual response time and error speed ripple, but also in terms of the fractal dimension (DF) of the rotor speed signal, by verifying the hypothesis that the use of a more efficient control system results in a higher DF of the controlled variable. Starting from a basic structure of an ESO-type observer which, by its structure, allows the estimation of both the PMSM rotor speed and a term incorporating the disturbances on the system (from which, in this case, an estimate of the PMSM load torque can be extracted), four variants of observers are proposed, obtained by combining the use of a multiple neural network (NN) load torque observer and an RL-TD3 agent. The numerical simulations performed in MATLAB/Simulink validate the superior performance obtained by using properly trained RL-TD3 agents, both in the case of sensored and sensorless control.

29 May 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Marcel NicolaMarcel Nicola
Marcel Nicola
Claudiu-Ionel NICOLAClaudiu-Ionel NICOLA
Claudiu-Ionel NICOLA
DSDan Selisteanu
Dan Selisteanu
ICIONETE Catalin Cosmin
IONETE Catalin Cosmin
GSGHEORGHE-DORIN SENDRESCU
GHEORGHE-DORIN SENDRESCU
Starting from the fact that one of the global control strategies of the Permanent Magnet Synchronous Motor (PMSM), namely the Direct Torque Control (DTC) type control strategy, is characterised by the fact that the inner flux and torque control loop usually uses hysteresis ON-OFF type controllers and the oscillations introduced by them have to be cancelled out by the outer speed loop controller (which is usually a PI speed controller and whose performance is good around the global operating points and for relatively small variations of the external parameters and disturbances caused in particular by the load torque variation), while retaining the advantages of the DTC strategy, this paper presents the improvement of the performance of the PMSM sensorless control system using Proportional Integrator (PI), PI Equilibrium Optimizer Algorithm (EOA), Fractional Order (FO) PI, Tilt Integral Derivative (TID) and FO Lead-Lag for constant flux, and Sliding Mode Control (SMC) and FOSMC for variable flux. The performance indicators of the control system are the usual ones: response time, settling time, overshoot, steady-state error and speed ripple, plus another one given by the fractal dimension (FD) of the PMSM rotor speed signal, and the hypothesis that the FD of the controlled signal is higher when the control system provides better performance is verified. The paper also presents the basic equations of the PMSM, based on which the synthesis of integer and fractional controllers, the synthesis of an observer for estimating the PMSM rotor speed, electromagnetic torque and stator flux are presented. The comparison of the performance of the proposed control systems and the demonstration of the parametric robustness are performed by numerical simulations in Matlab/Simulink using Simscape Electrical and Fractional Order Modelling and Control (FOMCON). Real-time control based on an embedded system using a TMS320F28379D controller demonstrates the good performance of the PMSM sensorless control system based on the DTC strategy in a complete hardware-in-the-loop (HIL) implementation.