David Carruthers

Dr. David Carruthers


Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1990
Verified
Book Chapter
Closed access
PDF file
DCDavid Carruthers
David Carruthers
JHJ. C. R. Hunt
J. C. R. Hunt

23 November 2017 in Atmosphere
Verified
Journal Article
Open access
PDF file
CLChun Lin
Chun Lin
NMNicola Masey
Nicola Masey
HWHao Wu
Hao Wu
MJMark Jackson
Mark Jackson
DCDavid Carruthers
David Carruthers
MHMathew Heal
Mathew Heal
To reduce inaccuracies in the measurement of air pollutants by portable monitors it is necessary to establish quantitative calibration relationships against their respective reference analyser. This is usually done under controlled laboratory conditions or one-off static co-location alongside a reference analyser in the field, neither of which may adequately represent the extended use of portable monitors in exposure assessment research. To address this, we investigated ways of establishing and evaluating portable monitor calibration relationships from repeated intermittent deployment cycles over an extended period involving stationary deployment at a reference site, mobile monitoring, and completely switched off. We evaluated four types of portable monitors: Aeroqual Ltd. (Auckland, New Zealand) S500 O3 metal oxide and S500 NO2 electrochemical; RTI (Berkeley, CA, USA) MicroPEM PM2.5; and, AethLabs (San Francisco, CA, USA) AE51 black carbon (BC). Innovations in our study included: (i) comparison of calibrations derived from the individual co-locations of a portable monitor against its reference analyser or from all the co-location periods combined into a single dataset; and, (ii) evaluation of calibrated monitor estimates during transient measurements with the portable monitor close to its reference analyser at separate times from the stationary co-location calibration periods. Within the ~7 month duration of the study, ‘combined’ calibration relationships for O3, PM2.5, and BC monitors from all co-locations agreed more closely on average with reference measurements than ‘individual’ calibration relationships from co-location deployment nearest in time to transient deployment periods. ‘Individual’ calibrations relationships were sometimes substantially unrepresentative of the ‘combined’ relationships. Reduced quantitative consistency in field calibration relationships for the PM2.5 monitors may have resulted from generally low PM2.5 concentrations that were encountered in this study. Aeroqual NO2 monitors were sensitive to both NO2 and O3 and unresolved biases. Overall, however, we observed that with the ‘combined’ approach, ‘indicative’ measurement accuracy (±30% for O3, and ±50% for BC and PM2.5) for 1 h time averaging could be maintained over the 7-month period for the monitors evaluated here.

31 October 2011 in Journal of the Air & Waste Management Association
Verified
Journal Article
Closed access
DCDavid Carruthers
David Carruthers
MSMartin D. Seaton
Martin D. Seaton
CMChristine A. McHugh
Christine A. McHugh
XSXiangyu Sheng
Xiangyu Sheng
ESEfisio Solazzo
Efisio Solazzo
EVEmilie Vanvyve
Emilie Vanvyve
ADMS and AERMOD are the two most widely used dispersion models for regulatory purposes. It is, therefore, important to understand the differences in the predictions of the models and the causes of these differences. The treatment by the models of flat terrain has been discussed previously; in this paper the focus is on their treatment of complex terrain. The paper includes a discussion of the impacts of complex terrain on airflow and dispersion and how these are treated in ADMS and AERMOD, followed by calculations for two distinct cases: (i) sources above a deep valley within a relatively flat plateau area (Clifty Creek power station, USA); (ii) sources in a valley in hilly terrain where the terrain rises well above the stack tops (Ribblesdale cement works, England). In both cases the model predictions are markedly different. At Clifty Creek, ADMS suggests that the terrain markedly increases maximum surface concentrations, whereas the AERMOD complex terrain module has little impact. At Ribblesdale, AERMOD predicts very large increases (a factor of 18) in the maximum hourly average surface concentrations due to plume impaction onto the neighboring hill; although plume impaction is predicted by ADMS, the increases in concentration are much less marked as the airflow model in ADMS predicts some lateral deviation of the streamlines around the hill.

29 November 2012 in Meteorological Applications
Verified
Journal Article
Open access
PDF file
DCDavid Carruthers
David Carruthers
AEAndrew Ellis
Andrew Ellis
JHJulian Hunt
Julian Hunt
P.W. ChanP.W. Chan
P.W. Chan
A theoretical and computational study is presented of the wind flow over the mountain ridges to the south of Hong Kong International Airport given the upwind profiles of ‘mean’ velocity and temperature. A sensitivity study shows how large variations in wind speed, wind shear and wind direction occur on the approach path when the upwind flow from the southeast is stably stratified above the boundary layer with a significant inversion no more than a few hundred metres above the ridge (height about 450 m). The Froude number is close to unity. The effects of vertical wind shear across the inversion layer reduce the speed‐up, and directional wind shear changes the surface flow direction. The observed horizontal length scales along the approach are about equal to the projected widths of the predominant features of the ridges and valleys. For an extreme wind event there was found to be satisfactory agreement between the wind speed measured by a landing aircraft and the predictions of the fast quasi‐linear analytically based computer model FLOWSTAR. This suggests that near real time application of the model and near real time monitoring with remote and in situ instruments can be used to predict these extreme flow events and hence give warnings about them. Conclusions are drawn about how such predictive modelling could be developed.

4 May 2022 in Royal Society Open Science
Verified
Journal Article
Open access
MSMarc Stettler
Marc Stettler
RNRobert T. Nishida
Robert T. Nishida
POPedro M. de Oliveira
Pedro M. de Oliveira
LMLeo C. C. Mesquita
Leo C. C. Mesquita
TJTyler J. Johnson
Tyler J. Johnson
ABAdam Boies
Adam Boies
There is ongoing and rapid advancement in approaches to modelling the fate of exhaled particles in different environments relevant to disease transmission. It is important that models are verified by comparison with each other using a common set of input parameters to ensure that model differences can be interpreted in terms of model physics rather than unspecified differences in model input parameters. In this paper, we define parameters necessary for such benchmarking of models of airborne particles exhaled by humans and transported in the environment during breathing and speaking.

19 June 2020 in Atmosphere
Verified
Journal Article
Open access
PDF file
Yasemin AktasYasemin Aktas
Yasemin Aktas
KWKai Wang
Kai Wang
YZYu Zhou
Yu Zhou
MOMurnira Othman
Murnira Othman
JSJenny Stocker
Jenny Stocker
JHJulian Hunt
Julian Hunt
High air temperature and high humidity, combined with low wind speeds, are common trends in the tropical urban climates, which collectively govern heat-induced health risks and outdoor thermal comfort under the given hygrothermal conditions. The impact of different urban land-uses on air temperatures is well-documented by many studies focusing on the urban heat island phenomenon; however, an integrated study of air temperature and humidity, i.e., the human-perceived temperatures, in different land-use areas is essential to understand the impact of hot and humid tropical urban climates on the thermal comfort of urban dwellers for an appraisal of potential health risks and the associated building energy use potential. In this study, we show through near-surface monitoring how these factors vary in distinct land-use areas of Kuala Lumpur city, characterized by different morphological features (high-rise vs. low-rise; compact vs. open), level of anthropogenic heating and evapotranspiration (built-up vs. green areas), and building materials (concrete buildings vs. traditional Malay homes in timber) based on the calculated heat index (HI), apparent temperature (TApp) and equivalent temperature (TE) values in wet and dry seasons. The results show that the felt-like temperatures are almost always higher than the air temperatures in all land-use areas, and this difference is highest in daytime temperatures in green areas during the dry season, by up to about 8 °C (HI)/5 °C (TApp). The TE values are also up to 9% higher in these areas than in built-up areas. We conclude that tackling urban heat island without compromising thermal comfort levels, hence encouraging energy use reduction in buildings to cope with outdoor conditions requires a careful management of humidity levels, as well as a careful selection of building morphology and materials.