Cristina Carmona-Pérez

Mrs. Cristina Carmona-Pérez


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SCSANDRA ALCARAZ CLARIANA
SANDRA ALCARAZ CLARIANA
LGLOURDES GARCIA-LUQUE
LOURDES GARCIA-LUQUE
JGJuan Luis Garrido-Castro
Juan Luis Garrido-Castro
César Fernandez-de-las-PeñasCésar Fernandez-de-las-Peñas
César Fernandez-de-las-Peñas
CCCristina Carmona-Pérez
Cristina Carmona-Pérez
Francisco Alburquerque-SendínFrancisco Alburquerque-Sendín
Francisco Alburquerque-Sendín
Our aims were to identify potential differences in muscle mechanical properties (MMPs) of cervical and lumbar tissues and in spinal range of motion (ROM) between patients with acute low back pain (LBP) or acute neck pain (NP) and healthy controls, and to identify if ROMs and MMPs are able to identify subjects among the three groups. Clinical variables (pain, disability, fear of movement, kinesiophobia, quality of life), MMPs and ROMs were obtained in 33 subjects with acute LBP, 33 with acute NP, and 33 healthy control subjects. Between-groups differences and explanatory models to discriminate groups depending on MMPs and ROMs were calculated. The results showed that cervical tone was higher in patients with acute NP than in controls, while cervical decrement was higher in both spinal pain groups. Patients with acute NP showed reduced cervical flexion when compared to acute LBP and control groups, and also cervical rotation, but just against controls. Furthermore, lumbar flexion was reduced in patients with acute LBP when compared to those with acute NP. Cervical decrement was able to discriminate spinal pain individuals from controls in a multinominal regression (R2: Cox–Snell estimation = 0.533; Nagelkerke estimation = 0.600). Lumbar flexion differentiated patients with acute LBP and controls, whereas cervical flexion differentiated patients with acute NP and controls. This study supports a tendency of the affectation of other spinal regions when only one is affected.

1 February 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCCristina Carmona-Pérez
Cristina Carmona-Pérez
JGJuan Luis Garrido-Castro
Juan Luis Garrido-Castro
FVFrancisco Torres Vidal
Francisco Torres Vidal
SCSANDRA ALCARAZ CLARIANA
SANDRA ALCARAZ CLARIANA
LGLOURDES GARCIA-LUQUE
LOURDES GARCIA-LUQUE
DRDaiana Priscila Rodrigues-de-Souza
Daiana Priscila Rodrigues-de-Souza
Objective: This study aimed to determine the validity and reliability of Inertial Measurement Units (IMUs) for the assessment of craniocervical range of motion (ROM) in patients with cerebral palsy (CP). Methods: twenty-three subjects with CP and 23 controls, aged between 4 and 14 years, were evaluated on two occasions, separated by 3 to 5 days. An IMU and a Cervical Range of Motion device (CROM) were used to assess craniocervical ROM in the three spatial planes. Validity was assessed by comparing IMU and CROM data using the Pearson correlation coefficient, the paired t-test and Bland–Altman plots. Intra-day and inter-day relative reliability were determined using the Intraclass Correlation Coefficient (ICC). The Standard Error of Measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90) were obtained for absolute reliability. Results: High correlations were detected between methods in both groups on the sagittal and frontal planes (r > 0.9), although this was reduced in the case of the transverse plane. Bland–Altman plots indicated bias below 5º, although for the range of cervical rotation in the CP group, this was 8.2º. The distance between the limits of agreement was over 23.5º in both groups, except for the range of flexion-extension in the control group. ICCs were higher than 0.8 for both comparisons and groups, except for inter-day comparisons of rotational range in the CP group. Absolute reliability showed high variability, with most SEM below 8.5º, although with worse inter-day results, mainly in CP subjects, with the MDC90 of rotational range achieving more than 20º. Conclusions: IMU application is highly correlated with CROM for the assessment of craniocervical movement in CP and healthy subjects; however, both methods are not interchangeable. The IMU error of measurement can be considered clinically acceptable; however, caution should be taken when this is used as a reference measure for interventions.

14 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SCSANDRA ALCARAZ CLARIANA
SANDRA ALCARAZ CLARIANA
LGLOURDES GARCIA-LUQUE
LOURDES GARCIA-LUQUE
JGJuan Luis Garrido-Castro
Juan Luis Garrido-Castro
IAI. Concepción Aranda-Valera
I. Concepción Aranda-Valera
MLMaría Lourdes Ladehesa-Pineda
María Lourdes Ladehesa-Pineda
Francisco Alburquerque-SendínFrancisco Alburquerque-Sendín
Francisco Alburquerque-Sendín
Different musculoskeletal disorders are a source of pain in the spinal region; most of them can be divided into mechanical, such as low back pain (LBP), or inflammatory origins, as is the case of axial spondyloarthritis (axSpA). Nevertheless, insufficient information is available about the muscle negative consequences of these conditions. Thus, the objective of this study was to identify whether mechanical muscle properties (MMPs) of cervical and lumbar muscles are different between patients with axSpA, subacute LBP (sLBP), and healthy controls. Furthermore, we aimed identify whether MMPs were related to sociodemographic and clinical variables in various study groups. The MMPs, sociodemographic, and clinical variables were obtained in 43 patients with axSpA, 43 subjects with sLBP, and 43 healthy controls. One-way ANOVAs and ROC curves were applied to identify whether the MMPs could differentiate between the study groups. Intra-group Pearson r coefficients to test the associations between MMPs and the rest of the variables were calculated. The results showed that axSpA subjects have a higher tone and stiffness and a lower relaxation and creep than sLBP and healthy ones (p < 0.05). All lumbar and cervical MMPs, except for decrement, could correctly classify axSpA and healthy subjects and axSpA and sLBP patients (in both cases, Area Under the Curve > 0.8). However, no MMP could differentiate between sLBP and healthy subjects. Each group had a different pattern of bivariate correlations between MMPs and sociodemographic and clinical data, with a worse state and progression of the axSpA group associated with a higher tone and stiffness in both spinal regions. This study supports that MMPs are different and show different patterns of correlations depending on the type of spinal pain.

9 December 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
DRDaiana Priscila Rodrigues-de-Souza
Daiana Priscila Rodrigues-de-Souza
SCSANDRA ALCARAZ CLARIANA
SANDRA ALCARAZ CLARIANA
LGLOURDES GARCIA-LUQUE
LOURDES GARCIA-LUQUE
CCCristina Carmona-Pérez
Cristina Carmona-Pérez
JGJuan Luis Garrido-Castro
Juan Luis Garrido-Castro
Francisco Alburquerque-SendínFrancisco Alburquerque-Sendín
Francisco Alburquerque-Sendín
An analysis of the muscle mechanical properties (MMPs) of the pelvic floor muscles (PFMs) is relevant for understanding the physiopathology of urinary incontinence (UI). However, there is no objective and reliable methodology currently available for quantifying the MMPs of PFMs. Thus, the objective was to determine the intra-rater and inter-rater reliability of the MMPs of PFM assessment with a hand-held tonometer device, called the MyotonPRO, in young women with and without UI. Sociodemographic and pelvic floor questionnaires, plus MMPs of PFMs were assessed in 38 nulliparous women with UI and 40 matched healthy women by two trained physiotherapists on two different occasions, 48–72 h apart. Good to excellent absolute reliability was found for tone, stiffness, and decrement of both intra- and inter-rater analyses in both study groups (Intraclass Correlation Coefficient ranged from 0.75 to 0.92), with a trend of lower values for relaxation and creep. The standard error of measurement (SEM) did not achieve 10% of the mean values for any MMPs. The minimum detectable change (MDC) values were also provided for clinical applications. In conclusion, the relative reliability of tone, stiffness, and the assessment of the decrement of PFMs with MyotonPRO is good to excellent for UI and healthy women. The SEM and MDC values were acceptable for their application in clinical settings.

1 September 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
CCCristina Carmona-Pérez
Cristina Carmona-Pérez
Alberto Pérez-RuizAlberto Pérez-Ruiz
Alberto Pérez-Ruiz
JGJuan Luis Garrido-Castro
Juan Luis Garrido-Castro
FVFrancisco Torres Vidal
Francisco Torres Vidal
SCSANDRA ALCARAZ CLARIANA
SANDRA ALCARAZ CLARIANA
Francisco Alburquerque-SendínFrancisco Alburquerque-Sendín
Francisco Alburquerque-Sendín
Objective: The aim of this study was to design and propose a new test based on inertial measurement unit (IMU) technology, for measuring cervical posture and motor control in children with cerebral palsy (CP) and to evaluate its validity and reliability. Methods: Twenty-four individuals with CP (4–14 years) and 24 gender- and age-matched controls were evaluated with a new test based on IMU technology to identify and measure any movement in the three spatial planes while the individual is seated watching a two-minute video. An ellipse was obtained encompassing 95% of the flexion/extension and rotation movements in the sagittal and transversal planes. The protocol was repeated on two occasions separated by 3 to 5 days. Construct and concurrent validity were assessed by determining the discriminant capacity of the new test and by identifying associations between functional measures and the new test outcomes. Relative reliability was determined using the intraclass correlation coefficient (ICC) for test–retest data. Absolute reliability was obtained by the standard error of measurement (SEM) and the Minimum Detectable Change at a 90% confidence level (MDC90). Results: The discriminant capacity of the area and both dimensions of the new test was high (Area Under the Curve ≈ 0.8), and consistent multiple regression models were identified to explain functional measures with new test results and sociodemographic data. A consistent trend of ICCs higher than 0.8 was identified for CP individuals. Finally, the SEM can be considered low in both groups, although the high variability among individuals determined some high MDC90 values, mainly in the CP group. Conclusions: The new test, based on IMU data, is valid and reliable for evaluating posture and motor control in children with CP.