Roser Porta

Mrs. Roser Porta

Pediatrics, Hospital Universitari Germans Trias i Pujol, Barcelona, Catalonia, Spain
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2002 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
XDXavier Demestre
Xavier Demestre
GGGemma Ginovart
Gemma Ginovart
JFJosep Figueras-Aloy
Josep Figueras-Aloy
RPRoser Porta
Roser Porta
XKXavier Krauel
Xavier Krauel
FRFrederic Raspall
Frederic Raspall

7 January 2012 in European Journal of Clinical Pharmacology
Verified
Journal Article
Closed access
PDF file
RPRoser Porta
Roser Porta
LSLara Sánchez
Lara Sánchez
MNMarta Nicolás
Marta Nicolás
CGCarmen García
Carmen García
MMMarta Martínez
Marta Martínez

1 April 2015 in Breastfeeding Medicine
Verified
Journal Article
Closed access
Sergio VerdSergio Verd
Sergio Verd
RPRoser Porta
Roser Porta
FBFrancesc Botet
Francesc Botet
AGAntonio Gutiérrez
Antonio Gutiérrez
GGGemma Ginovart
Gemma Ginovart
IPIsabel Iglesias Plata
Isabel Iglesias Plata
This study evaluated the impact of an exclusive human milk diet to nourish extremely low birth weight infants in the neonatal intensive care unit. This multicenter pre-post retrospective study included all inborn infants <1,000 g admitted to four Level IV neonatal intensive care units either before or after implementing a donor human milk policy. The feeding protocol was unchanged in both periods. Collected data included maternal/infant demographics, infant clinical data, and enteral intake as mother's own milk, donor milk, and formula. Two hundred one infants were enrolled. Infant growth and other clinical outcomes were similar in both groups. Exposure to mother's own milk at discharge was not different. Median time in oxygen and duration of mechanical ventilation were significantly higher among formula-fed infants (63 versus 192 hours [p=0.046] and 24 versus 60 hours [p=0.016], respectively). Our results add evidence supporting the safety of donor milk. This study also found an association between exposure to formula in preterm infants and the requirement for respiratory support, a finding that warrants further investigation.

12 September 2019 in Nutrients
Verified
Journal Article
Open access
PDF file
RPRoser Porta
Roser Porta
ECEva Capdevila
Eva Capdevila
FBFrancesc Botet
Francesc Botet
Gemma GinovartGemma Ginovart
Gemma Ginovart
EMElisenda Moliner-Calderón
Elisenda Moliner-Calderón
Sergio VerdSergio Verd
Sergio Verd
Multiple pregnancy increases the risk of a range of adverse perinatal outcomes, including breastfeeding failure. However, studies on predictive factors of breastfeeding duration in preterm twin infants have a conflicting result. The purpose of this observational study was to compare feeding practices, at hospital discharge, of twin and singleton very low birth weight infants. The study is part of a prospective survey of a national Spanish cohort of very low birth weight infants (SEN1500) that includes 62 neonatal units. The study population comprised all infants registered in the network from 2002 to 2013. They were grouped into singletons and multiples. The explanatory variables were first analyzed using univariate models; subsequently, significant variables were analyzed simultaneously in a multiple stepwise backward model. During the twelve-year period, 32,770 very low birth weight infants were included in the database, of which 26.957 were discharged alive and included in this analysis. Nine thousand seven hundred and fifty-eight neonates were multiples, and 17,199 were singletons. At discharge, 31% of singleton infants were being exclusively breastfed, 43% were bottle-fed, and 26% were fed a combination of both. In comparison, at discharge, only 24% of multiple infants were exclusively breastfed, 43% were bottle-fed, and 33% were fed a combination of both (p < 0.001). On multivariable analysis, twin pregnancy had a statistically significant, but small effect, on cessation of breastfeeding before discharge (OR 1.10; 95% CI: 1.02, 1.19). Risks of early in-hospital breastfeeding cessation were also independently associated with multiple mother-infant stress factors, such as sepsis, intraventricular hemorrhage, retinopathy, necrotizing enterocolitis, intubation, and use of inotropes. Instead, antibiotic treatment at delivery, In vitro fertilization and prenatal steroids were associated with a decreased risk for shorter in-hospital breastfeeding duration. Multiple pregnancy, even in the absence of pathological conditions associated to very low birth weight twin infants, may be an impeding factor for in-hospital breastfeeding.

22 September 2017 in The Journal of Maternal-Fetal & Neonatal Medicine
Verified
Journal Article
Closed access
RPRoser Porta
Roser Porta
ECEva Capdevila
Eva Capdevila
FBFrancesc Botet
Francesc Botet
SVSergi Verd
Sergi Verd
GGGemma Ginovart
Gemma Ginovart
SNSen1500 Network
Sen1500 Network

1 April 2021 in Breastfeeding Medicine
Verified
Journal Article
Closed access
RPRoser Porta
Roser Porta
NMNatàlia Miralles
Natàlia Miralles
APAnna Paltrinieri
Anna Paltrinieri
BIBeatriz Ibáñez
Beatriz Ibáñez
JGJúlia Giménez
Júlia Giménez
AVAna Vega
Ana Vega
The amount of milk production in mothers of babies admitted to the neonatal intensive care unit (NICU) is mostly determined by some actions focused on the first hours and days after birth. Working for an improvement in our previous results in terms of maternal expressed breast milk (MEBM) production, we designed a pilot project and a small observational study. After increasing the number of breast milk pumps to allow full-time availability and implementing educational strategies and updated information for parents, the volume of MEBM production by day 14 after birth was doubled and increased to >500 mL per day. The rate of exclusive breastfeeding at discharge improved from 26.67% to 76.19%. The cost of the use of donor milk per patient decreased by 15.7%. This study is an example of a cost-beneficial quality improvement strategy. It demonstrates the importance of an optimal supply of breast milk pumps in NICU and educational interventions focused on enhancing MEBM production.