REDO-FIRM evaluated safety and effectiveness of conventional vs. focal impulse and rotor modulation (FIRM)-guided ablation of recurrent persistent or paroxysmal atrial fibrillation (AF) after an initial AF ablation procedure. This prospective, multicentre, randomized study included patients with a single prior AF ablation, but with recurrent AF and reconnected pulmonary veins (PVs). Conventional ablation generally included PV re-isolation; however, additional ablation was permitted per physician discretion. In the FIRM arm, beyond PV re-isolation, basket catheter-based FIRM mapping created dynamic animations of putative rotors, which were targeted for ablation. Between May 2016 and July 2019, 269 subjects were randomized, with 243 subjects completing 12-month follow-up. Ablation beyond re-pulmonary vein isolation, the FIRM vs. Conventional arms did not differ significantly: cavo-tricuspid isthmus –9.0% vs. 15.3%, caval vein isolation –1.5% vs. 0.8%, non-PV trigger –2.2% vs. 3.8%, other –11.9% vs. 13.0%. Single procedure 12-month freedom from AF/atrial tachycardia/atrial flutter-recurrence was 63.3% (76/120) vs. 59.0% (72/122) in the FIRM and Conventional arms (P = 0.3503). Efficacy was similar in the paroxysmal and persistent AF subgroups (P = 0.22 and P = 0.48). The 10-day and 12-month safety endpoints were achieved in 93.3% vs. 93.8% (P = 0.89) and 88.4% vs. 93.4% (P = 0.22) in the FIRM and Conventional arms, respectively. In REDO-FIRM, as compared to standard ablation, FIRM-guided ablation did not provide additional efficacy in redo ablation procedures, but FIRM-guided ablation was equally safe. Additional studies are necessary to identify any potential population able to benefit from FIRM-guided ablation.
Aims Paroxysmal atrial fibrillation (PAF) is predominantly triggered by focal ectopies located within the pulmonary veins (PV). The BITMAP Study (Breakthrough and Isolation Trial: Mapping and Ablation of Pulmonary Veins) investigated prospectively the safety and efficacy of a catheter design with circumferential mapping and ablation electrodes. We report the phenomenon of ST-segment-elevation during catheter placement in the left atrium (LA) and superior PVs in this multi-centre study. Methods and results Forty-three patients (57±10 years) with PAF were included in this study. Radiofrequency catheter (RFC) ablation supported by the 4F REVELATION Helix microcatheter (Cardima Inc., Freemont, CA, USA) with eight distal-coiled microelectrodes for bipolar mapping and ablation. RFC was applied at the ostial region of PV (30 W, 45–50°C) with a maximum of four RFC applications per electrode. In four of the 43 patients from three centres, we recorded the occurrence of ST-segment-elevation greater than 0.2 mV and accompanying left thoracic discomfort. The ECG changes and the symptoms started abruptly and lasted for 4.2±2.2 min. Pericardial effusion could instantaneously be excluded by echocardiography in all cases. Coronary angiograms were performed in three patients with the longest episodes; no thrombotic material or air emboli were present. The symptoms and the ECG changes resolved completely in all patients. Conclusion The phenomenon of ST-segment-elevation during LA- and PV-mapping in patients with PAF may be a common occurrence. In this prospective multi-centre trial, we demonstrated the reversibility of this phenomenon; no cardiovascular or cerebral damage was reported during both the procedure and the follow-up. Although the mechanism is still unclear, vasospasm may contribute to this phenomenon because of autonomic dysregulation.
Background: Hypertension (HTN) constitutes a risk factor for the development of atrial fibrillation (AF), as well as for thromboembolic and bleeding events. We analysed the outcome after catheter ablation of AF in HTN in a cohort from the prospective multicenter German Ablation Registry. Methods: Between 03/2008 and 01/2010, 626 patients undergoing AF-ablation were analysed. Patients diagnosed with HTN (n = 386) were compared with patients without HTN (n = 240) with respect to baseline, procedural and long-term outcome parameters. Results: Patients with HTN were older and more often presented with persistent forms of AF and cardiac comorbidities. Major and moderate in-hospital complications were low. At long-term follow-up, major cardiovascular events were rare in both groups. Rates of AF-recurrence, freedom from antiarrhythmic medication and repeat ablation were not statistically different between groups. Most patients reported improvement of symptoms and satisfaction with the treatment. However, patients with HTN more frequently complained of dyspnea of New York Heart Association (NYHA) class ≥ II and angina. They were more often rehospitalized, particularly when persistent AF had been diagnosed. Conclusion: Catheter ablation of AF is associated with low complication rates and favorable arrhythmia-related results in patients with HTN. Residual clinical symptoms may be due to cardiac comorbidities and require additional attention in this important subgroup of AF-patients.
Aims To analyse the long-term safety of implantable cardioverter defibrillators (ICDs) in patients discharged within 24 h or after 2- 5-day hospitalization, respectively, after complication-free implantation, in circumstances of actual care. Methods and results Patients in the multicentre, nationwide German DEVICE registry were contacted 12–15 months after their first ICD implantation or device replacement. Data were collected on complications, potential arrhythmic events, syncope, resuscitation, ablation procedures, cardiac events, hospitalizations, heart failure status, change of medication, and quality of life. Of 2356 patients from 43 centres, 527 patients were discharged within 24 h and 1829 were hospitalized routinely for >24 h after complication-free implantations. The disease profiles and rates of co-morbidities were similar at baseline for both cohorts. During between 384 and 543 days of follow-up, there were no significant differences between the groups in terms of complications, hospitalizations, or quality of life. One-year rates of death were 4.5% in patients discharged early compared with 7.2% in hospitalized patients (hazard ratio 0.65; 95% confidence interval 0.42–1.02; P = 0.052). Rates of major adverse cardiovascular events or defibrillator events were not higher in patients discharged after 24 h. In both groups, a high rate of patients declared that they would opt for the procedure again in the same situation. Conclusion Data from a large-scale registry reflecting current day-to-day practice in Germany suggest that most patients can be discharged safely within 24 h of successful ICD implantation if there are no procedure-related events. Follow-up data up to 1.5 years after implantation did not raise long-term safety concerns.