In this study, we obtained and characterized a composite film made of lead zirconate titanate (PZT) piezoelectric ceramic and non-polar polyvinylidene fluoride (α-PVDF) as a functional material. The scanning electron microscopy (SEM) results show this composite film to have mixed connectivity due to the agglomeration of some of the PZT particles. The response of the composite to an applied ac voltage at 4110 Hz has a slope of 0.074 nm/V. The measured displacement is in the range of 0-30 nm for electric voltages ranging from 0-400 V. The experimental results show the composite performance as an acoustic emission (AE) sensor to be good agreement with the response of a commercial standard microphone in the frequency range of 2-6 kHz. By applying 2 kN of cyclic force at a frequency of 3 Hz, we obtained an 80 V peak signal and calculated a dissipated power equal to 158 μW.
Resistive sensor arrays (RSAs) have been developed for a variety of applications depending on resolution requirements, active sensor area, and cost. Composite-based piezoresistive sensors are commonly found in RSAs. However, they present an intrinsic problem related to the parasitic current paths that flow through the whole composite, which cause a crosstalk effect. Various circuits have been proposed to reduce the crosstalk effect in sensor arrays. In this paper, we compare a number of readout circuits with PSpice models, mainly those including voltage feedback (VF) circuits and zero potential (ZP) circuits. To develop an array with 3600 sensors using a piezoresistive composite, we selected the improved isolated drive feedback circuit (IIDFC). Using nodal analysis, we were able to develop an alternative mathematical circuit model, which allowed us to identify its unique characteristics, including the influence of array size on the crosstalk effect and the restriction on minimal impedance that the array elements must attain to maintain a minimum error. In a resistive array with 3600 sensors and a sensor range of 10-100 $\text{k}\Omega $ , we obtained an absolute error of less than 3.56%. In addition, the proposed mathematical circuit model obtained a maximum absolute error difference of 0.03% when compared with the PSpice model with the precision operational amplifier OPA37. Thus, using the IIDFC circuit and considering the minimal allowable impedance, it is possible to maintain a reduced error in an RSA with a large number of sensors.
The use and development of plantar pressure measurement systems (PPMs) have increased in recent years, in order to understand and objectively evaluate the interaction between the feet and the support surfaces. The PPMs are mainly made with resistive sensor arrays, which have problems associated with crosstalk reading errors. Several circuits aimed at reducing the crosstalk effect have been investigated; however, none of these circuits were evaluated in large-area matrices or practical applications. Thus, in this work, we explain the development and characterization of the Lieb- Scan system, which is a stationary PPMs with 2304 sensels based on the improved isolated drive feedback circuit for crosstalk control. The commercial equipment recommended for PPM linearization and characterization of a large-area matrix is a high-cost pneumatic device. In this sense, we propose a characterization by areas using a universal testing machine and an artificial neural network, since each sensel has an individual and unique response. Although the LiebScan system supports pressures up to 300 kPa, it presents competitive characteristics when compared with commercial equipment, in terms of accuracy, hysteresis, creep, crosstalk, and center of pressure processing. The most remarkable feature among these cited before is the low crosstalk effect, with a mean error of 0.23%. The pressures measured because of this crosstalk error are below the pressure threshold, thus, the crosstalk effect is practically null. This work describes the design, development, characterization and detailed evaluation of a PPMs with commercial features.
The quality of the alignment and adjustment of lower limb prostheses is fundamental in the rehabilitation process, mainly because it contributes to preventing the prostheses from being abandoned. Prosthesis alignment is often performed subjectively based on the experience and knowledge of the healthcare professional. In this work, we present the development of a referenced static alignment equipment for lower limb prostheses. The equipment has an instrumental platform that measures important parameters for suitable alignment of lower limb prostheses, giving the therapist objective data that allow for the best adjustment and alignment of the prosthesis to the individual. The developed system has a novel procedure in the prosthesis adjustment where through a movable base. The prosthesis length can be adjusted with a smooth displacement of 0.35 mm. This minimum displacement is important because the difficulty is greater when the longitudinal adjustment required in the prosthesis is less than 10 mm. The equipment can measure the individual’s center of pressure (COP) in the anteroposterior (AP) and mediolateral (ML) directions, making it possible to adjust the knee and ankle angulation of the prosthesis, and also the alignment in the frontal plane between the healthy and the prosthetic lower limb. The measurement weight accuracy was less than 1%, while the COP measurement accuracies were found to be less than 0.4 cm in both the AP and ML directions. With a sampling frequency of 80 Hz, it is possible to carry out stabilometry analysis and use these data to improve the prosthesis adjustment procedure.
30 December 2019 in Revista Brasileira de Física Médica
Um instrumento para medir a intensidade (fluxo de energia) de fótons na faixa da mamografia (22 a 33 kVp) foi implementado. O instrumento consiste em uma câmara piroelétrica, acoplando um sensor piroelétrico de metaniobato de chumbo (PbNb2O6) e o circuito condicionador de sinal. O material utilizado para desenvolver a câmara foi o poliácido lático. O circuito condicionador de sinal é um conversor de corrente em tensão de alta sensibilidade. A intensidade da radiação foi determinada a partir da taxa de exposição utilizando uma câmara de ionização a gás. Uma simulação da emissão do espectro do molibdênio, o elemento comumente utilizado nos alvos de raios-X dos mamógrafos, na faixa de 22 a 33 kVp, usando o sensor piroelétrico foi realizada utilizando o software DTSA-II e comparada a emissão do mesmo espectro utilizando o detector padrão do software, o sensor Si(Li). Os resultados mostram que a resposta do instrumento implementado é linear com a tensão do tubo de raios-X e com a intensidade da radiação e, a emissão do espectro do molibdênio pode ser muito bem representada pelo instrumento piroelétrico.