Robert Michael Moss

Dr. Robert Michael Moss

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2014 in Journal of Applied Crystallography
Verified
Journal Article
Open access
DPDavid Pickup
David Pickup
RMRobert Michael Moss
Robert Michael Moss
RNRobert Newport
Robert Newport
NXFitis a program for obtaining optimized structural parameters from amorphous materials by simultaneously fitting X-ray and neutron pair-distribution functions. Partial correlation functions are generated inQspace, summed and Fourier transformed for comparison with the experimental data inrspace.NXFituses the Nelder–Mead method to vary a set of `best guess' parameters to achieve a fit to experimentally derived data. The output parameters fromNXFitare coordination number, atomic separation and disorder parameter for each atomic correlation used in the fitting process. The use ofNXFithas been demonstrated by fitting both X-ray and neutron diffraction data from two quite different amorphous materials: a melt-quenched (Na2O)0.5(P2O5)0.5glass and a (TiO2)0.18(SiO2)0.82sol–gel.

11 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RMRobert Michael Moss
Robert Michael Moss
AAAmany S. Amin
Amany S. Amin
CCChiaki Crews
Chiaki Crews
CPColin A. Purdie
Colin A. Purdie
LJLee B. Jordan
Lee B. Jordan
SVSarah J. Vinnicombe
Sarah J. Vinnicombe
This pilot study examines the correlation of X-ray diffraction (XRD) measurements with the histopathological analysis of breast tissue. Eight breast cancer samples were investigated. Each sample contained a mixture of normal and cancerous tissues. In total, 522 separate XRD measurements were made at different locations across the samples (8 in total). The resulting XRD spectra were subjected to principal component analysis (PCA) in order to determine if there were any distinguishing features that could be used to identify different tissue components. 99.0% of the variation between the spectra were described by the first two principal components (PC). Comparing the location of points in PC space with the classification determined by histopathology indicated correlation between the shape/magnitude of the XRD spectra and the tissue type. These results are encouraging and suggest that XRD could be used for the intraoperative or postoperative classification of bulk tissue samples.

9 February 2022 in International journal of legal medicine
Verified
Journal Article
Open access
PDF file
RCRachael M. Carew
Rachael M. Carew
Francesco IacovielloFrancesco Iacoviello
Francesco Iacoviello
CRCarolyn Rando
Carolyn Rando
RMRobert Michael Moss
Robert Michael Moss
RSRobert Speller
Robert Speller
RMRuth M. Morgan
Ruth M. Morgan
The evaluation of 3D printed osteological materials has highlighted the difficulties associated with accurately representing fine surface details on printed bones. Moreover, there is an increasing need for reconstructions to be demonstrably accurate and reliable for use in the criminal justice system. The aim of this study was to assess the surface quality of 3D prints (n = 9) that presented with micromorphological alterations from trauma, taphonomy and pathology processes. The archaeological bones were imaged using micro-CT scanning and 3D printed with selective laser sintering (SLS) printing. A multi-method experimental approach subsequently identified: (1) the 3D printed bones to be metrically accurate to within 1.0 mm; (2) good representation of micromorphological surface features overall, albeit with some loss of intricate details, depths, and fine textures that can be important for visual processing; (3) five of the nine 3D printed bones were quantitatively scored as accurate using the visual comparison method; and, (4) low mesh comparison distances (± 0.2 mm) between the original models and the digitised 3D print models. The findings offer empirical data that can be used to underpin 3D printed reconstructions of exhibits for use in courts of law. In addition, an adaptable pathway was presented that can be used to assess 3D print accuracy in future reconstructions.

15 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
SASuad Alghamdi
Suad Alghamdi
SBStephanie Bennett
Stephanie Bennett
CCCarol Crean
Carol Crean
JGJoydip Ghosh
Joydip Ghosh
HGHarry Gibbard
Harry Gibbard
PSPaul Sellin
Paul Sellin
We have investigated the performance of formamidinium lead bromide (FAPbBr3) perovskite X-ray detectors fabricated from polycrystalline material that is pressed into a pellet at high pressures. FAPbBr3 has been shown to exhibit a remarkable combination of electrical and physical properties, such that mechanically-formed polycrystalline pellets exhibit good charge transport properties suitable for use as X-ray detectors. We characterise the morphology and structure of FAPbBr3 pellets using photoluminescence (PL), electron microscopy (SEM) and X-ray diffraction (XRD), and demonstrate an improvement in the microstructure, density, and charge transport performance of the material as the pressure is increased from 12 MPa to 124 MPa. The use of annealing of the pellets after pressing also improves the stability and charge transport performance of the devices. Using a 40 kV X-ray beam, a maximum X-ray sensitivity of 169 µC Gy−1 cm−2 was measured, and the fast time response of the devices was demonstrated using a chopped X-ray beam.

1 February 2017 in Journal of Instrumentation
Verified
Journal Article
Open access
PDF file
RMRobert Michael Moss
Robert Michael Moss
CCChiaki Crews
Chiaki Crews
MWMatthew Wilson
Matthew Wilson
RSRobert Speller
Robert Speller
This paper introduces miniPixD: a new, compact system that utilises transmission X-ray imaging and X-ray diffraction (XRD) to locate and identify materials of interest within an otherwise opaque volume. The system and the embodied techniques have utility in security screening, medical diagnostics, non-destructive testing (NDT) and quality assurance (QA). This paper outlines the design of the system including discussion on the choice of components and presents some data from relevant samples which are compared to other energy dispersive and angular dispersive XRD techniques.

30 June 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MLMaria Laura Perez Lara
Maria Laura Perez Lara
JKJia C. Khong
Jia C. Khong
MWMatthew D. Wilson
Matthew D. Wilson
BCBen D. Cline
Ben D. Cline
RMRobert Michael Moss
Robert Michael Moss
Online proton range verification is a rapidly emerging field characterised by its ability to reduce the error margins during proton beam therapy, as it is patient-specific and in vivo. In particular, secondary prompt gamma detection is a promising tool to monitor the dose delivery. The present research evaluates the capability of a HEXITEC detector to identify the prompt gammas produced during proton beam therapy, and assesses its potential for online range verification. To achieve this, the detector is placed at one side of a water phantom, which is irradiated at different proton energies in the University College London Hospital Proton Centre. For further analysis, Monte Carlo simulations are performed using Geant4 and the same geometry as the experiment. The results show that HEXITEC has the potential to be part of a detection system that could identify secondary prompt gammas within the secondary field produced inside the target, allowing for the in-detector discrimination of these particles via cluster size analysis. The comparison between data sets shows that there is a high level of accuracy between the model and the experimental measurements in terms of secondary flux and charge diffusion inside the detector, which poses the model as a fundamental tool for future optimisation studies.