Aim: The effects of treatment with hydrochlorothiazide (HCTZ) combined with amiloride were elucidated and compared to HCTZ treatment alone and combined with acemetacin or triamterene in a Japanese adult patient with congenital nephrogenic diabetes insipidus. Methods: The study was divided into seven periods: (1) HCTZ and acemetacin; (2) control period; (3) HCTZ; (4) a second control period; (5) HCTZ and amiloride; (6) a third control period, and (7) HCTZ and triamterene. Fluid intake, urine volume, urinary Na, K, creatinine, and osmolality and serum Na, K, Cl, CO2, and osmolality were measured, and free water clearance and proximal and distal tubular Na reabsorption rates were calculated. Results: Without drug administration, the urine volume was about 8,000 ml/day. The urine volume was reduced to about 6,000 ml/day with HCTZ. A further urine volume reduction to about 5,000 ml/day was obtained with the second drug administration, and the effects were similar among the three regimens. Serum and urinary osmolality and free water clearance were also similar among the three combinations, whereas the urinary potassium excretion was the least, and the serum potassium concentration was the highest with HCTZ plus amiloride. Besides, no alkalosis was observed only with this combination. Conclusion: HCTZ plus amiloride may be superior to HCTZ plus acemetacin and HCTZ plus triamterene in preventing hyperkaliuria, hypokalemia, and metabolic alkalosis.
The aim of this study was to create a new phantom for a 3 Tesla (3T) magnetic resonance imaging (MRI) device for the calculation of the apparent diffusion coefficient (ADC) using diffusion‑weighted imaging (DWI), and to mimic the ADC values of normal and tumor tissues at various temperatures, including the physiological body temperature of 37˚C. The phantom was produced using several concentrations of sucrose from 0 to 1.2 M, and the DWI was performed using various phantom temperatures. The accurate ADC values were calculated using the DWIs of the phantoms, and an empirical formula was developed to calculate the ADC values of the phantoms from an arbitrary sucrose concentration and arbitrary phantom temperature. The empirical formula was able to produce ADC values ranging between 0.33 and 3.02x10‑3 mm2/sec, which covered the range of ADC values of the human body that have been measured clinically by 3T MRI in previous studies. The phantom and empirical formula developed in this study may be available to mimic the ADC values of the clinical human lesion by 3T MRI.
7 November 2001 in Computerized Medical Imaging and Graphics
Increased heart dose during postoperative radiotherapy (RT) for left‑sided breast cancer (BC) can cause cardiac injury, which can decrease patient survival. The deep inspiration breath‑hold technique (DIBH) is becoming increasingly common for reducing the mean heart dose (MHD) in patients with left‑sided BC. However, treatment planning and DIBH for RT are laborious, time‑consuming and costly for patients and RT staff. In addition, the proportion of patients with left BC with low MHD is considerably higher among Asian women, mainly due to their smaller breast volume compared with that in Western countries. The present study aimed to determine the optimal machine learning (ML) model for predicting the MHD after RT to pre‑select patients with low MHD who will not require DIBH prior to RT planning. In total, 562 patients with BC who received postoperative RT were randomly divided into the trainval (n=449) and external (n=113) test datasets for ML using Python (version 3.8). Imbalanced data were corrected using synthetic minority oversampling with Gaussian noise. Specifically, right‑left, tumor site, chest wall thickness, irradiation method, body mass index and separation were the six explanatory variables used for ML, with four supervised ML algorithms used. Using the optimal value of hyperparameter tuning with root mean squared error (RMSE) as an indicator for the internal test data, the model yielding the best F2 score evaluation was selected for final validation using the external test data. The predictive ability of MHD for true MHD after RT was the highest among all algorithms for the deep neural network, with a RMSE of 77.4, F2 score of 0.80 and area under the curve‑receiver operating characteristic of 0.88, for a cut‑off value of 300 cGy. The present study suggested that ML can be used to pre‑select female Asian patients with low MHD who do not require DIBH for the postoperative RT of BC.
We developed a new hybrid gel phantom using carrageenan and gellan gum for the purpose of visualizing three-dimensional temperature distribution. The phantom, which contains carrageenan, gellan gum, non-ionic surface active agent, potassium chloride, n-butanol, sodium azide, and water, shows good transparency at room temperature, and has the advantage that the heated region becomes white and opaque due to segregation of the surface active agent. Carrageenan and gellan gum were added to improve the transparency and fragility of the hybrid gel. Potassium chloride was used to adjust the electrical conductivity of the gel to a range of 5-130 MHz, so that it would be equivalent to that of muscle tissue for each frequency used by electromagnetic heating devices. N-butanol was used to adjust the clouding temperature to a range between 45 and 55 degrees C. In the present study we clarified the important properties of the new phantom, and developed formulae for easy determination of the amounts of ingredients necessary for the desired clouding temperature and electric conductivity. The characteristics of this phantom are: a) a solid form to avoid convection by heat conduction; b) sufficient strength without fragility to form a torso without the use of a reinforcing agent; c) high transparency at room temperature and visualization of the heating area as a white turbidity; d) time-lapse and accurate visualization of the changing temperature area without thermal hysteresis; e) electrical properties similar to those of human tissues; f) ease of production; and g) low cost and good safety. This phantom might assist oncologists in their routine checking and study of the performance of electromagnetic heating devices for hyperthermia and radiofrequency ablation.
Deep inspiration breath-hold (DIBH) is an excellent technique to reduce the incidental radiation received by the heart during radiotherapy in patients with breast cancer. However, DIBH is costly and time-consuming for patients and radiotherapy staff. In Asian countries, the use of DIBH is restricted due to the limited number of patients with a high mean heart dose (MHD) and the shortage of radiotherapy personnel and equipment compared to that in the USA. This study aimed to develop, evaluate, and compare the performance of ten machine learning algorithms for predicting MHD using a patient’s body mass index and single-slice CT parameters to identify patients who may not require DIBH. Machine learning models were built and tested using a dataset containing 207 patients with left-sided breast cancer who were treated with field-in-field radiotherapy with free breathing. The average MHD was 251 cGy. Stratified repeated four-fold cross-validation was used to build models using 165 training data. The models were compared internally using their average performance metrics: F2 score, AUC, recall, accuracy, Cohen’s kappa, and Matthews correlation coefficient. The final performance evaluation for each model was further externally analyzed using 42 unseen test data. The performance of each model was evaluated as a binary classifier by setting the cut-off value of MHD ≥ 300 cGy. The deep neural network (DNN) achieved the highest F2 score (78.9%). Most models successfully classified all patients with high MHD as true positive. This study indicates that the ten models, especially the DNN, might have the potential to identify patients who may not require DIBH.