Harry Ruda

Dr. Harry Ruda

Center for Advanced Nanotechnology, Department of Materials Science and Engineering, University of Toronto, Toronto, ON M5S 3E4, Canada
orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
ZWZ. H. Wu
Z. H. Wu
MSM. Sun
M. Sun
XMX. Y. Mei
X. Y. Mei
Harry RudaHarry Ruda
Harry Ruda
Growth of high-quality single-crystal AlGaAs nanowires was demonstrated using the vapor–liquid–solid (VLS) mechanism with molecular-beam epitaxy(MBE). Highly ordered AlGaAs nanowire arrays and GaAs ∕ AlGaAs multilayernanowires were also prepared. Photoluminescence(PL) from homogeneous AlGaAs and GaAs ∕ AlGaAs multilayernanowires was measured. The Al composition of the AlGaAs nanowires was found to be significantly lower than that for planar MBEfilmsgrown under the same conditions, as determined from PL and energy-dispersive x-ray spectroscopy measurements. This is explained in terms of the different growth mechanisms for VLS and normal MBE. Such AlGaAs nanowires are expected to have a wide range of applications in electronic and photonic devices.

14 May 2024 in Cells
Verified
Journal Article
Open access
PDF file
James C. L. ChowJames C. L. Chow
James C. L. Chow
Harry RudaHarry Ruda
Harry Ruda
The advent of FLASH radiotherapy (FLASH-RT) has brought forth a paradigm shift in cancer treatment, showcasing remarkable normal cell sparing effects with ultra-high dose rates (>40 Gy/s). This review delves into the multifaceted mechanisms underpinning the efficacy of FLASH effect, examining both physicochemical and biological hypotheses in cell biophysics. The physicochemical process encompasses oxygen depletion, reactive oxygen species, and free radical recombination. In parallel, the biological process explores the FLASH effect on the immune system and on blood vessels in treatment sites such as the brain, lung, gastrointestinal tract, skin, and subcutaneous tissue. This review investigated the selective targeting of cancer cells and the modulation of the tumor microenvironment through FLASH-RT. Examining these mechanisms, we explore the implications and challenges of integrating FLASH-RT into cancer treatment. The potential to spare normal cells, boost the immune response, and modify the tumor vasculature offers new therapeutic strategies. Despite progress in understanding FLASH-RT, this review highlights knowledge gaps, emphasizing the need for further research to optimize its clinical applications. The synthesis of physicochemical and biological insights serves as a comprehensive resource for cell biology, molecular biology, and biophysics researchers and clinicians navigating the evolution of FLASH-RT in cancer therapy.

30 July 2023 in Cancers
Verified
Journal Article
Open access
PDF file
Sarkar Noor Mohammad Siddique, BScSarkar Noor Mohammad Siddique, BSc
Sarkar Noor Mohammad Siddique, BSc
Harry RudaHarry Ruda
Harry Ruda
James C. L. ChowJames C. L. Chow
James C. L. Chow
Radiotherapy (RT) using ultra-high dose rate (UHDR) radiation, known as FLASH RT, has shown promising results in reducing normal tissue toxicity while maintaining tumor control. However, implementing FLASH RT in clinical settings presents technical challenges, including limited depth penetration and complex treatment planning. Monte Carlo (MC) simulation is a valuable tool for dose calculation in RT and has been investigated for optimizing FLASH RT. Various MC codes, such as EGSnrc, DOSXYZnrc, and Geant4, have been used to simulate dose distributions and optimize treatment plans. Accurate dosimetry is essential for FLASH RT, and radiation detectors play a crucial role in measuring dose delivery. Solid-state detectors, including diamond detectors such as microDiamond, have demonstrated linear responses and good agreement with reference detectors in UHDR and ultra-high dose per pulse (UHDPP) ranges. Ionization chambers are commonly used for dose measurement, and advancements have been made to address their response nonlinearities at UHDPP. Studies have proposed new calculation methods and empirical models for ion recombination in ionization chambers to improve their accuracy in FLASH RT. Additionally, strip-segmented ionization chamber arrays have shown potential for the experimental measurement of dose rate distribution in proton pencil beam scanning. Radiochromic films, such as GafchromicTM EBT3, have been used for absolute dose measurement and to validate MC simulation results in high-energy X-rays, triggering the FLASH effect. These films have been utilized to characterize ionization chambers and measure off-axis and depth dose distributions in FLASH RT. In conclusion, MC simulation provides accurate dose calculation and optimization for FLASH RT, while radiation detectors, including diamond detectors, ionization chambers, and radiochromic films, offer valuable tools for dosimetry in UHDR environments. Further research is needed to refine treatment planning techniques and improve detector performance to facilitate the widespread implementation of FLASH RT, potentially revolutionizing cancer treatment.

3 February 2004 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
SCS. B. Clendenning
S. B. Clendenning
SAS. Aouba
S. Aouba
MRM. S. Rayat
M. S. Rayat
DGD. Grozea
D. Grozea
JSJ. B. Sorge
J. B. Sorge
IMI. Manners
I. Manners

26 August 2006 in Discover Nano
Verified
Journal Article
Open access
PDF file
Harry RudaHarry Ruda
Harry Ruda
JPJohn C. Polanyi
John C. Polanyi
JYJody S.Y. Yang
Jody S.Y. Yang
ZWZhanghua Wu
Zhanghua Wu
UPUsha Philipose
Usha Philipose
HHH.K. Haugen
H.K. Haugen
There is intense and growing interest in one-dimensional (1-D) nanostructures from the perspective of their synthesis and unique properties, especially with respect to their excellent optical response and an ability to form heterostructures. This review discusses alternative approaches to preparation and organization of such structures, and their potential properties. In particular, molecular-scale printing is highlighted as a method for creating organized pre-cursor structure for locating nanowires, as well as vapor–liquid–solid (VLS) templated growth using nano-channel alumina (NCA), and deposition of 1-D structures with glancing angle deposition (GLAD). As regards novel optical properties, we discuss as an example, finite size photonic crystal cavity structures formed from such nanostructure arrays possessing highQ and small mode volume, and being ideal for developing future nanolasers.

26 June 2023 in Encyclopedia
Verified
Journal Article
Open access
PDF file
James C. L. ChowJames C. L. Chow
James C. L. Chow
Harry RudaHarry Ruda
Harry Ruda
Flash radiotherapy (Flash-RT) is an innovative technique used in radiotherapy for cancer treatment because it delivers an extremely high dose of radiation (>40 Gy/s) to the tumour in a very short period of time, typically within a fraction of a second. This ultra-fast delivery of radiation distinguishes Flash-RT from conventional radiotherapy, which typically involves the delivery of radiation over a longer time period, often several minutes. Studies conducted in cell and preclinical models suggested that Flash-RT may spare normal tissues from radiation-related side effects, such as skin toxicity, gastrointestinal complications, and damage to organs-at-risk. This is believed to be due to the unique normal tissue response to the ultra-high dose rate. Nevertheless, while Flash-RT shows promising results in preclinical and early clinical studies, one should note that the technique is still in the early stages of development. This entry provides a comprehensive exploration of the immense potentials of Flash-RT, covering its background, mechanisms, radiation sources, recent experimental findings based on cell and preclinical models, and future prospects. It aims to provide valuable insights into this innovative radiotherapy technology for anyone interested in the subject.