Marius Heitzer

Dr. Marius Heitzer

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2020 in Materials
Verified
Journal Article
Open access
PDF file
AIAhmad Ibrahim
Ahmad Ibrahim
MHMarius Heitzer
Marius Heitzer
ABAnna Bock
Anna Bock
FPFlorian Peters
Florian Peters
SMStephan Christian Möhlhenrich
Stephan Christian Möhlhenrich
KKKristian Kniha
Kristian Kniha
Aim: This in vitro study aimed to evaluate the effects of implant designs on primary stability in different bone densities and bony defects. Methods: Five implant types (tapered-tissue-level, tissue-level, zirconia-tissue-level, bone-level, and BLX implants) were used in this assessment. The implants were inserted into four different artificial bone blocks representing varying bone-density groups: D1, D2, D3, and D4. Aside from the control group, three different types of defects were prepared. Using resonance frequency analysis and torque-in and -out values, the primary stability of each implant was evaluated. Results: With an increased defect size, all implant types presented reduced implant stability values measured by the implant stability quotient (ISQ) values. Loss of stability was the most pronounced around circular defects. Zirconia and bone-level implants showed the highest ISQ values, whereas tissue level titanium implants presented the lowest stability parameters. The implant insertion without any thread cut led to a small improvement in primary implant stability in all bone densities. Conclusions: Compared with implants with no peri-implant defects, the three-wall and one-wall defect usually did not provide significant loss of primary stability. A significant loss of stability should be expected when inserting implants into circular defects. Implants with a more aggressive thread distance could increase primary stability.

27 July 2021 in Medicina
Verified
Journal Article
Open access
PDF file
MKMarie Sophie Katz
Marie Sophie Katz
MOMark Ooms
Mark Ooms
MHMarius Heitzer
Marius Heitzer
FPFlorian Peters
Florian Peters
PWPhilipp Winnand
Philipp Winnand
AMAli Modabber
Ali Modabber
Background and objectives: In oral and maxillofacial operations, the iliac crest is a commonly used donor site from which to harvest bone for augmentation prior to dental implantation or for reconstruction of jaw defects caused by trauma or pathological lesions. In an aging society, the proportion of elderly patients undergoing iliac crest bone grafting for oral augmentation is growing. Although postoperative morbidity is usually moderate to low, the age and health of the patient should be considered as risk factors for complications and delayed mobilization after the operation. The aim of this retrospective study was to evaluate the postoperative morbidity and complications in elderly patients after the harvesting of iliac crest bone grafts for oral surgery. Material and Methods: Data were collected from a total of 486 patients (aged 7–85) who had a surgical procedure that included the harvesting of iliac crest bone grafts for intraoral transplantation. All patients were operated on between 2005 and 2021 in the Department for Oral and Maxillofacial Surgery of the University Hospital in Aachen, Germany. As parameters for postoperative morbidity and complications, gait disturbances, hypesthesia of cutaneous nerves, incision hernias, iliac crest fractures, delayed wound healing, and unfavorable scar formation at the donor site were all evaluated. Results: The study was performed with 485 patients due to the exclusion of one patient as the only one from whom grafts were taken from both sides. When younger and older patients were compared, neither gait disturbances (p = 0.420), nor hernias (p = 0.239), nor fractures (p = 0.239), nor hypesthesia (p = 0.297), nor wound healing delay (p = 0.294), nor scar problems (p = 0.586) were significantly different. However, the volume of the graft was significantly correlated with the duration of the hospital stay (ρ = 0.30; p < 0.01) but not with gait disturbances (ρ = 0.60; p = 0.597). Additionally, when controlling for age (p = 0.841), sex (p = 0.031), ASA class (p = 0.699), preexisting orthopedic handicaps (p = 0.9828), and the volume of the bone graft (p = 0.770), only male sex was associated with the likelihood of suffering gait disturbances (p = 0.031). Conclusions: In conclusion, harvesting bone grafts from the anterior iliac crest for intraoral augmentation is a safe procedure for both young and elderly patients. Although there is some postoperative morbidity, such as gait disturbances, hypesthesia, scar formation, or delayed wound healing at the donor site, rates for these minor complications are low and mostly of short duration. Major complications, such as fractures or incision hernias, are very rare. However, in our study, the volume of the bone graft was associated with a longer stay in hospital, and this should be considered in the planning of iliac crest bone graft procedures.

20 January 2023 in Oral Oncology
Verified
Journal Article
Closed access
PWPhilipp Winnand
Philipp Winnand
MOMark Ooms
Mark Ooms
MHMarius Heitzer
Marius Heitzer
MLMatthias Lammert
Matthias Lammert
FHFrank Hölzle
Frank Hölzle
AMAli Modabber
Ali Modabber

23 March 2022 in International Journal of Oral and Maxillofacial Surgery
Verified
Journal Article
Closed access
MHMarius Heitzer
Marius Heitzer
KKK. Kniha
K. Kniha
MKM.S. Katz
M.S. Katz
PWPhilipp Winnand
Philipp Winnand
FPF. Peters
F. Peters
AMAli Modabber
Ali Modabber

30 June 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MHMarius Heitzer
Marius Heitzer
JBJulia Brockhaus
Julia Brockhaus
KKKristian Kniha
Kristian Kniha
FMFelix Merkord
Felix Merkord
FPFlorian Peters
Florian Peters
AMAli Modabber
Ali Modabber
Conventional anastomoses with interrupted sutures are challenging and inevitably associated with trauma to the vessel walls. The goal of this study was to evaluate a novel alternative adhesive-based suture-free anastomosis technique that uses an intraluminal stent. Overall, 120 porcine coronary vessels were analyzed in an ex vivo model and were examined for their mechanical (n = 20 per cohort) and hydrostatic strength (n = 20 per cohort). Anastomoses were made using the novel VIVO adhesive with an additional intraluminal nitinol stent and was compared to interrupted suture anastomosis and to native vessels. Sutureless anastomoses withstood pressures 299 ± 4.47 [mmHg] comparable to native vessels. They were performed significantly faster 553.8 ± 82.44 [sec] (p ≤ 0.001) and withstood significantly higher pressures (p ≤ 0.001) than sutured anastomoses. We demonstrate that the adhesive-based anastomosis can also resist unphysiologically high longitudinal tensile forces with a mean of 1.33 [N]. Within the limitations of an in vitro study adhesive-based suture-free anastomosis technique has the biomechanical potential to offer a seamless alternative to sutured anastomosis because of its stability, and faster handling. In vivo animal studies are needed to validate outcomes and confirm safety.

1 November 2021 in Annals of Anatomy - Anatomischer Anzeiger
Verified
Journal Article
Closed access
MHMarius Heitzer
Marius Heitzer
SMStephan Christian Möhlhenrich
Stephan Christian Möhlhenrich
KKKristian Kniha
Kristian Kniha
RTRené Tolba
René Tolba
SJStefan Jockenhoevel
Stefan Jockenhoevel
AMAli Modabber
Ali Modabber