Cameron Shearer

Dr. Cameron Shearer

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 October 2016 in Chemical Reviews
Verified
Journal Article
Closed access
LYLePing Yu
LePing Yu
CSCameron Shearer
Cameron Shearer
JSJoe Shapter
Joe Shapter

19 February 2016 in Nanotechnology
Verified
Journal Article
Closed access
PDF file
CSCameron Shearer
Cameron Shearer
ASAshley Slattery
Ashley Slattery
ASAndrew J Stapleton
Andrew J Stapleton
JSJoe Shapter
Joe Shapter
Christopher GibsonChristopher Gibson
Christopher Gibson
Graphene has emerged as a material with a vast variety of applications. The electronic, optical and mechanical properties of graphene are strongly influenced by the number of layers present in a sample. As a result, the dimensional characterization of graphene films is crucial, especially with the continued development of new synthesis methods and applications. A number of techniques exist to determine the thickness of graphene films including optical contrast, Raman scattering and scanning probe microscopy techniques. Atomic force microscopy (AFM), in particular, is used extensively since it provides three-dimensional images that enable the measurement of the lateral dimensions of graphene films as well as the thickness, and by extension the number of layers present. However, in the literature AFM has proven to be inaccurate with a wide range of measured values for single layer graphene thickness reported (between 0.4 and 1.7 nm). This discrepancy has been attributed to tip-surface interactions, image feedback settings and surface chemistry. In this work, we use standard and carbon nanotube modified AFM probes and a relatively new AFM imaging mode known as PeakForce tapping mode to establish a protocol that will allow users to accurately determine the thickness of graphene films. In particular, the error in measuring the first layer is reduced from 0.1–1.3 nm to 0.1–0.3 nm. Furthermore, in the process we establish that the graphene-substrate adsorbate layer and imaging force, in particular the pressure the tip exerts on the surface, are crucial components in the accurate measurement of graphene using AFM. These findings can be applied to other 2D materials.

22 February 2014 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
CSCameron Shearer
Cameron Shearer
Alexey CherevanAlexey Cherevan
Alexey Cherevan
DEDominik Eder
Dominik Eder

1 September 2016 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JSJohn E. Sader
John E. Sader
RBRiccardo Borgani
Riccardo Borgani
Christopher GibsonChristopher Gibson
Christopher Gibson
DHDavid B. Haviland
David B. Haviland
MHMichael J. Higgins
Michael J. Higgins
TZTian Zheng
Tian Zheng
Atomic force microscope (AFM) users often calibrate the spring constants of cantilevers using functionality built into individual instruments. This calibration is performed without reference to a global standard, hindering the robust comparison of force measurements reported by different laboratories. Here, we describe a virtual instrument (an internet-based initiative) whereby users from all laboratories can instantly and quantitatively compare their calibration measurements to those of others—standardising AFM force measurements—and simultaneously enabling non-invasive calibration of AFM cantilevers of any geometry. This global calibration initiative requires no additional instrumentation or data processing on the part of the user. It utilises a single website where users upload currently available data. A proof-of-principle demonstration of this initiative is presented using measured data from five independent laboratories across three countries, which also allows for an assessment of current calibration.

18 April 2018 in Advanced Sustainable Systems
Verified
Journal Article
Open access
PDF file
MWMax J. H. Worthington
Max J. H. Worthington
CSCameron Shearer
Cameron Shearer
LELouisa J. Esdaile
Louisa J. Esdaile
JCJonathan Campbell
Jonathan Campbell
Christopher GibsonChristopher Gibson
Christopher Gibson
JCJustin M. Chalker
Justin M. Chalker
Crude oil and hydrocarbon fuel spills are a perennial threat to aquatic environments. Inexpensive and sustainable sorbents are needed to mitigate the ecological harm of this pollution. To address this need, this study features a low‐density polysulfide polymer that is prepared by the direct reaction of sulfur and used cooking oils. Because both sulfur and cooking oils are hydrophobic, the polymer has an affinity for hydrocarbons such as crude oil and diesel fuel and can rapidly remove them from seawater. Through simple mechanical compression, the oil can be recovered and the polymer can be reused in oil spill remediation. The polysulfide is unique because it is prepared entirely from repurposed waste: sulfur is a by‐product of the petroleum industry and used cooking oil can be used as a comonomer. In this way, sulfur waste from the oil industry is used to make an effective sorbent for combatting pollution from that same sector.

9 February 2015 in Journal of Materials Chemistry A
Verified
Journal Article
Open access
PDF file
MBMunkhbayar Batmunkh
Munkhbayar Batmunkh
CSCameron Shearer
Cameron Shearer
MBMark J. Biggs
Mark J. Biggs
JSJoe Shapter
Joe Shapter
This review outlines the progress that has been reported on using carbon based nanostructures in perovskite solar cells and discusses their possible further applications to deliver high efficiency, long lifetime, low cost PSCs.