A new formulation of active contours based on explicit functions has been recently suggested. This novel framework allows real-time 3-D segmentation since it reduces the dimensionality of the segmentation problem. In this paper, we propose a B-spline formulation of this approach, which further improves the computational efficiency of the algorithm. We also show that this framework allows evolving the active contour using local region-based terms, thereby overcoming the limitations of the original method while preserving computational speed. The feasibility of real-time 3-D segmentation is demonstrated using simulated and medical data such as liver computer tomography and cardiac ultrasound images.
1 January 2013 in Ultrasound in Medicine & Biology
Arterial pulse wave velocity (PWV) is associated with increased mortality in aging and disease. Several studies have shown the accuracy of applanation tonometry carotid-femoral PWV (Cf-PWV) and the relevance of evaluating central aorta stiffness using 2D cardiovascular magnetic resonance (CMR) to estimate PWV, and aortic distensibility-derived PWV through the theoretical Bramwell-Hill model (BH-PWV). Our aim was to compare various methods of aortic PWV (aoPWV) estimation from 4D flow CMR, in terms of associations with age, Cf-PWV, BH-PWV and left ventricular (LV) mass-to-volume ratio while evaluating inter-observer reproducibility and robustness to temporal resolution. We studied 47 healthy subjects (49.5 ± 18 years) who underwent Cf-PWV and CMR including aortic 4D flow CMR as well as 2D cine SSFP for BH-PWV and LV mass-to-volume ratio estimation. The aorta was semi-automatically segmented from 4D flow data, and mean velocity waveforms were estimated in 25 planes perpendicular to the aortic centerline. 4D flow CMR aoPWV was calculated: using velocity curves at two locations, namely ascending aorta (AAo) and distal descending aorta (DAo) aorta (S1, 2D-like strategy), or using all velocity curves along the entire aortic centreline (3D-like strategies) with iterative transit time (TT) estimates (S2) or a plane fitting of velocity curves systolic upslope (S3). For S1 and S2, TT was calculated using three approaches: cross-correlation (TTc), wavelets (TTw) and Fourier transforms (TTf). Intra-class correlation coefficients (ICC) and Bland-Altman biases (BA) were used to evaluate inter-observer reproducibility and effect of lower temporal resolution. 4D flow CMR aoPWV estimates were significantly (p < 0.05) correlated to the CMR-independent Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with the strongest correlations for the 3D-like strategy using wavelets TT (S2-TTw) (R = 0.62, 0.65, 0.77 and 0.52, respectively, all p < 0.001). S2-TTw was also highly reproducible (ICC = 0.99, BA = 0.09 m/s) and robust to lower temporal resolution (ICC = 0.97, BA = 0.15 m/s). Reproducible 4D flow CMR aoPWV estimates can be obtained using full 3D aortic coverage. Such 4D flow CMR stiffness measures were significantly associated with Cf-PWV, BH-PWV, age and LV mass-to-volume ratio, with a slight superiority of the 3D strategy using wavelets transit time (S2-TTw).
This paper describes a free open source software in Matlab (named Creaseg, http://www.creatis.insa-lyon. fr/~bernard/creaseg) for the evaluation of the performance of different level-set based algorithms in the context of 2D image segmentation. The platform gives access to the implementation of six level-set methods that have been chosen in order to cover a wide range of data attachment terms (contour, region and localized approaches). The software also gives the possibility to compare the performance of the proposed algorithms on any kind of images. The performance can be evaluated either visually, or from similarity measurements between a reference and the results of the segmentation.
1 January 2014 in Computerized Medical Imaging and Graphics