Livio Mazzarella

Dr. Livio Mazzarella

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Building Engineering
Verified
Journal Article
Closed access
DDDelia D'AGostino
Delia D'AGostino
LMLivio Mazzarella
Livio Mazzarella


24 March 2023 in Energies
Verified
Journal Article
Open access
PDF file
Adriana AngelottiAdriana Angelotti
Adriana Angelotti
LMLivio Mazzarella
Livio Mazzarella
Cristina CornaroCristina Cornaro
Cristina Cornaro
Francesca FrascaFrancesca Frasca
Francesca Frasca
APAlessandro Prada
Alessandro Prada
Vincenzo CorradoVincenzo Corrado
Vincenzo Corrado
Calibration of the existing building simulation model is key to correctly evaluating the energy savings that are achievable through retrofit. However, calibration is a non-standard phase where different approaches can possibly lead to different models. In this study, an existing residential building is simulated in parallel by four research groups with different dynamic simulation tools. Manual/automatic methodologies and basic/detailed measurement data sets are used. The calibration is followed by a validation on two evaluation periods. Monitoring data concerning the windows opening by the occupants are used to analyze the calibration outcomes. It is found that for a good calibration of a model of a well-insulated building, the absence of data regarding the users’ behavior is more critical than uncertainty on the envelope properties. The automatic approach is more effective in managing the model complexity and reaching a better performing calibration, as the RMSE relative to indoor temperature reaches 0.3 °C compared to 0.4–0.5 °C. Yet, a calibrated model’s performance is often poor outside the calibration period (RMSE increases up to 10.8 times), and thus, the validation is crucial to discriminate among multiple solutions and to refine them, by improving the users’ behavior modeling.

1 November 2015 in Energy Procedia
Verified
Journal Article
Open access
AAAndrea Alongi
Andrea Alongi
LMLivio Mazzarella
Livio Mazzarella
Previous studies dealing with dynamic insulation technology neglect the microscopic interaction between the solid matrix of the porous material and the air flowing through the pore structure. The main goal of this work is to investigate this interaction, and its effects on the heat transfer phenomena at macroscopic scale using the Volume Average Method. At first, the microscopic geometry of two samples of rock wool is investigated through image analysis, leading to the evaluation of porosity and granulometry. Then, the volume averaging technique is applied to the microstructure of fibrous materials. Thermal dispersion and thermal tortuosity are introduced and evaluated through numerical simulations of simplified geometry in laminar and low-Pe conditions, and two regression equations are defined

10 January 2021 in Journal of Building Performance Simulation
Verified
Journal Article
Closed access
AAAndrea Alongi
Andrea Alongi
Adriana AngelottiAdriana Angelotti
Adriana Angelotti
LMLivio Mazzarella
Livio Mazzarella
A one-dimensional Finite Difference Model for Breathing Wall components under time dependent Dirichlet boundary conditions is presented. The algorithm undergoes a comprehensive validation against a dynamic analytical model, under either sinusoidal and generically periodic boundary conditions, adopting different airflow velocities and in relation to capacitive and resistive materials alternatively. It is found that the accurate prediction of the temperature profile inside the wall is influenced primarily by the timestep, whose optimal value can be identified through a preliminary frequency analysis of the boundary conditions. Moreover, for a better prediction of the surface heat flow density, and especially in insulating materials, refining the space grid below 1 mm is recommended, as well as the adoption of a 3-point numerical scheme. The numerical model is finally tested against experimental data on a porous concrete wall, showing that numerical errors may compare to other sources of uncertainties, regarding materials properties and boundary conditions.

22 May 2023 in Energies
Verified
Journal Article
Open access
PDF file
AAAndrea Alongi
Andrea Alongi
LSLuca Sala
Luca Sala
Adriana AngelottiAdriana Angelotti
Adriana Angelotti
LMLivio Mazzarella
Livio Mazzarella
Energy retrofit of existing buildings is based on the assessment of the starting performance of the envelope. The procedure for the in situ measurement of thermal conductance is described in the ISO 9869-1:2014, which provides two techniques for data processing: the average method (AM) and the dynamic method (DM). This work studies their effectiveness using virtual data from numerical simulations based on a finite difference model applied to different wall kinds, considering winter and summer boundary conditions alternatively (Italian Milan-Linate TMY). The estimated thermal conductances are compared to the reference theoretical values. The main purposes are: (i) defining the shortest test duration that provides acceptable results; (ii) assess the reliability of the criteria provided by the standard to evaluate the measurement quality; (iii) evaluate the sensitivity of both methods to variables such as wall properties, boundary conditions and others more specific to the DM (namely, the number of time constants and linear equations). The AM always provides acceptable estimates in winter (−3.1% ÷ 10% error), with better outcomes when indoor heat flux is considered, except for the highly insulated wall, but is not effective in summer, despite the fulfillment of the acceptance criteria for the highly insulated wall. The DM provides improvements in both seasons (0.05% ÷ 8.6% absolute values of error), for most virtual samples, and requires shorter sampling periods, even below the 3 days limit suggested by the standard. The test on the confidence interval indicated by the ISO 9869-1:2014 is not reliable and measurements are sensitive to the number of linear equations, that is left to the user’s discretion without strict indications. This work suggests a possible approach for overcoming this issue, which requires deeper future investigation.