Soocheol Yoon

Dr. Soocheol Yoon

Intelligent Systems Division, National Institute of Standards and Technology, Gaithersburg, Maryland, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 November 2016 in Computer-Aided Design and Applications
Verified
Journal Article
Closed access
BJByeong Woo Jeon
Byeong Woo Jeon
JUJumyung Um
Jumyung Um
Soocheol YoonSoocheol Yoon
Soocheol Yoon
SSSuh Suk-Hwan
Suh Suk-Hwan

5 August 2016 in Journal of Intelligent Manufacturing
Verified
Journal Article
Closed access
PDF file
Soocheol YoonSoocheol Yoon
Soocheol Yoon
JUJumyung Um
Jumyung Um
SSSuk-Hwan Suh
Suk-Hwan Suh
ISIan Stroud
Ian Stroud
JYJoo-Sung Yoon
Joo-Sung Yoon

15 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YLYa-Shian Li-Baboud
Ya-Shian Li-Baboud
AVAnn Virts
Ann Virts
RBRoger Bostelman
Roger Bostelman
Soocheol YoonSoocheol Yoon
Soocheol Yoon
ARAmaan Rahman
Amaan Rahman
MSMili Shah
Mili Shah
In recent years, exoskeleton test methods for industrial exoskeletons have evolved to include simulated laboratory and field environments. Physiological, kinematic, and kinetic metrics, as well as subjective surveys, are used to evaluate exoskeleton usability. In particular, exoskeleton fit and usability can also impact the safety of exoskeletons and their effectiveness at reducing musculoskeletal injuries. This paper surveys the state of the art in measurement methods applied to exoskeleton evaluation. A notional classification of the metrics based on exoskeleton fit, task efficiency, comfort, mobility, and balance is proposed. In addition, the paper describes the test and measurement methods used in supporting the development of exoskeleton and exosuit evaluation methods to assess their fit, usability, and effectiveness in industrial tasks such as peg in hole, load align, and applied force. Finally, the paper includes a discussion of how the metrics can be applied towards a systematic evaluation of industrial exoskeletons, current measurement challenges, and future research directions.

14 March 2015 in Journal of Intelligent Manufacturing
Verified
Journal Article
Closed access
PDF file
SSSeung-Jun Shin
Seung-Jun Shin
SSSuk-Hwan Suh
Suk-Hwan Suh
ISIan Stroud
Ian Stroud
Soocheol YoonSoocheol Yoon
Soocheol Yoon

1 March 2019
Verified
Conference Paper
Closed access
RBRoger Bostelman
Roger Bostelman
YLYa-Shian Li-Baboud
Ya-Shian Li-Baboud
AVAnn Virts
Ann Virts
Soocheol YoonSoocheol Yoon
Soocheol Yoon
MSMili Shah
Mili Shah
Exoskeletons are now being marketed by several manufacturers and yet there are currently no standard test methods to compare exoskeletons 33 Disclaimer: Commercial equipment, software, and materials are identified in order to adequately specify certain procedures. In no case does such identification imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the materials, equipment, or software are necessarily the best available for the purpose. to tasks. The National Institute of Standards and Technology (NIST) has been a key contributor to the formation of a new ASTM F48 standards committee on exoskeletons and has a project to research measurement science and test method developments in support of exoskeleton standards. This paper describes the NIST exoskeleton project efforts for one of several ongoing research areas (i.e., load handling) that targets typical industrial tasks. The paper will describe the design of the NIST Position and Load Test Apparatus for Exoskeletons (PoLoTAE), a reconfigurable testbed and its use within a NIST internal review board (IRB) study. Experimental results from the first load handling test described suggest potential significance of using the exoskeleton to alleviate physical exertion to the human with respect to gender, anthropometry, and fit. The potential capability of the exoskeleton test apparatus and methodology in simulating industrial tasks is positively indicated by the initial experiment. Lastly, future tests are outlined to improve the test methodology.

1 June 2019
Verified
Conference Paper
Closed access
Soocheol YoonSoocheol Yoon
Soocheol Yoon
RBRoger Bostelman
Roger Bostelman
Automatic through Autonomous - Unmanned Ground Vehicles (A-UGVs), as termed by ASTM Standards Committee F45 for Driverless Industrial Vehicles, have much potential for use in manufacturing operations thanks to their versatility and flexibility. To utilize A-UGVs efficiently and effectively, it is needed to specify how the vehicle will be used, in what environment, and how best to control it. By understanding the detailed performance of the A-UGV and the facility environment, the vehicle can potentially operate with maximized productivity. In this paper, various parameters of the A-UGV are analyzed to measure navigation and obstacle avoidance performance. A-UGV aspects related to various facility environments are defined in structural form with organic relations. Performance test methods were developed and verified in a mock facility environment combining ramps and obstacles to measure navigation and obstacle avoidance performance.