Nieke Karnaningroem

Prof. Dr. Nieke Karnaningroem


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Ecological Engineering
Verified
Journal Article
Open access
TZTien Zubaidah
Tien Zubaidah
NKNieke Karnaningroem
Nieke Karnaningroem
ASAgus Slamet
Agus Slamet
The river water Self-purification capacity is an essential indicator for a healthy river. Various organic and inorganic pollutants, both point sources and nonpoint sources, in most streams in Banjarmasin have been beyond the river self-purification capacity, which causes river water quality...

1 May 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
AAA Aliffia
A Aliffia
NKNieke Karnaningroem
Nieke Karnaningroem
The Utilization of Kali Surabaya River as water resources for drinking water is constrained by pollution from domestic and industrial waste and agricultural activities around the river banks. This study was aimed to calculate the pollution load capacity using QUAL2Kw model which presented the water quality. Study area from upstream (Cangkir) to downstream (Sepanjang) of the river was divided into 3 segments. The required data included primary data by sampling at determined points representing the condition of pollutant source. Secondary data included climatology, population, river hydraulic, and discharge and quality of pollution obtained from related institution. The water quality parameters analysed were BOD and COD, where the result exceeded the water quality standard of class I, while the DO was less than the standard requirement. Based on the simulation result, the value of pollutant load in each segment for BOD was 12,416 kg/day, 23,180 kg/day, and 17,759 kg/day while COD was 56,158 kg/day, 99,188 kg/day, and 74,316 kg/day. Then, the capacity of BOD in each segment was 1,681 kg/day, 1,138 kg/day, and 1,398 kg/day while COD is 12,396 kg/day, 8,150 kg/day, and 9,681 kg/day. This means that the pollutant load has exceeded the capacity of the river.

1 May 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
FPF A Putri
F A Putri
NKNieke Karnaningroem
Nieke Karnaningroem
Kali Surabaya River is one of the river in Surabaya that use as the water source of PDAM Surabaya. Moreover, Kali Surabaya River takes an important role of society, industry, agriculture and economic commerce in its surrounding area. The increasing of industry and domestic waste that dispose to Kali Surabaya River, causing the degradation of its water quality. From parameters DO, BOD, and COD of Kali Surabaya River, we can look for relation and mutual attachment to determine the class of water body of Kali Surabaya. The method that use in this case is system dynamics using Stella Model. The purpose of this modelling is to identify and determine the relation of DO, BOD and COD value that contains in Kali Surabaya river segment Karangpilang-Ngagel Surabaya, and to determine the class of water body of Kali Surabaya River segment Karangpilang-Ngagel using dynamic system method. The result of this modelling is prediction of DO parameter value that decreasing in 2018 at all three segments. In December 2018, concentration of DO in segment 1 is 3.79 mg/L; in segment 2 is 4.34 mg/L and in segment 3 is 3.72 mg/L. According to the prediction result from this model, DO value at all segments in November and December is still exceed the standard value of class II river standard, which is 4 mg/L. In the other hand, in January until October DO value at all segments is under the standard of class II river standard. The average DO value of Kali Surabaya River in 2018 is in the range of 3.72-4.9 mg/L.

25 December 2019 in IPTEK Journal of Proceedings Series
Verified
Journal Article
Open access
PDF file
MSMaria Setianingsih
Maria Setianingsih
NKNieke Karnaningroem
Nieke Karnaningroem
Water losses from water distribution networks have become a crucial problem. The BNA (Basic Need Approach) zone has high water losses above the standard for maximum tolerance ministry of public work as 20%. The water losses during September - December 2018 has experienced a fluctuation. the highest losses occurred in October at 36.05%, but in November the level of water losses decreased to 34.17%. The water balance can be used to know to understand the quantity, source, and charge of water losses. The water balance calculation in this study uses the WB-Easy Calc program version 4.05. Based on the result, the percentage of water losses 34,81% with the composition of real losses as 30,61% and apparent losses of 4.21%. On the other hand, the financial impact by the water losses was deficit as Rp. 4.593.648.335. Furthermore, gets to the action for each one of the above main components of the water balance in order to reduce water losses.

1 May 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
AWA Wicaksono
A Wicaksono
NKNieke Karnaningroem
Nieke Karnaningroem
Human necessity toward consumable drinking water increases along with population growth. People nowadays have a hard time obtaining clean water because of polluted river. To meet daily necessity of drinking water, a lot of industries open drinking water business, particularly refill drinking water facility (DAMIU). The utilization of refill drinking water facility has its own hazardous risk because of the doubtful quality, moreover if the customers aren’t paying attention towards the security and hygiene. This study used FMEA (Failure Mode Effect and Analysis) to determine the priority of failure incident in refill drinking water treatment process. This FMEA method was used because FMEA has advantage over other method in term of being more feasible and effective for operational improvement while being able to analyze risk in bigger and more complex scale. To determine the failure, we first did risk identification which contained failures information obtained from interview, quality test, and direct observation. Failure causes risk happened in refill drinking water facilities were analyzed using Fishbone method. The location of the study was in Rungkut District, Surabaya. The parameters used were turbidity, TDS, pH, and Total Coliform. Obtained risk should had a value to be measured and determined for the handling priority and to find improvement effort. The measurement value was called as RPN (Risk Priority Number) which was the multiply value of severity, occurrence, and detection. Based on analysis result using fishbone method there were 4 factors which caused failure for total coliform parameter. Then, it was analyzed using FMEA method, and it was found that failure happened within 3 highest priority, which was UV system contact duration, ozone system contact duration, and disinfection tool replacement and maintenance.

1 May 2019 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
IWI Wahyuningsih
I Wahyuningsih
NKNieke Karnaningroem
Nieke Karnaningroem
Refill water is one important element in filling the increasing drinking water demand. The price offered by refill water depot is significantly lower than packaged water, however, its quality does not meet the standards, and therefore it will potentially affect people’s health. This risk surfaces if refill water depot installation can’t treat raw water as well as the environment surrounding properly. Thus, identification to refill water production failure cause is needed to minimize the possibility of failure happening. Identification and risk analysis processes are based on risk management concept by using Failure Mode and Effect Analysis (FMEA). Failure cause identification is done using fishbone diagram to find the root of the problem causing the failure. The root of the failure will then be given score to determine the biggest risk stated in Risk Priority Number (RPN). RPN value is obtained through multiplying severity, occurrence, and detection. The biggest failure cause in refill water depot is in the disinfection technology used, which is the replacing and contact duration of regulation regarding refill water also causes failure in refill water production process.