Pengyu Li

Dr. Pengyu Li


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 July 2023 in Fire
Verified
Journal Article
Open access
PDF file
LLLonghui Liao
Longhui Liao
HLHong Li
Hong Li
PLPengyu Li
Pengyu Li
XBXiaohua Bao
Xiaohua Bao
Chengyu HongChengyu Hong
Chengyu Hong
PWPEICHEN WU
PEICHEN WU
The underground space in the Starting Area in the Guangzhou International Financial City is being developed to save resources and improve land benefits. However, high-density development has increased the likelihood of fires. Therefore, PyroSim and Pathfinder were used in this study to investigate the fire smoke flow and personnel evacuation in the underground space in the Starting Area. Firstly, the 2D temperature cloud map and the temperature and visibility recorded by sensor A over time of Zone I in the Starting Area were analyzed. Then, the 3D smoke diffusion, the 3D temperature diffusion map, and the value of thermocouple and smoke obscuration recorded by sensors of Zone II were analyzed. Next, smoke flow of Zones III to V in the Starting Area under different fire source positions was simulated. Finally, the personnel evacuation model was established to simulate the personnel flow rate and density. The simulation results show that the available safe evacuation time for people is 530 s when all the firefighting facilities fail and fire breaks out in Zone I. For large public spaces, the overall spread speed of fire is fast, which requires the use of the fire control system in time to control the spread of fire. Fortunately, the space of evacuation time is relatively sufficient; it only takes 143 s to evacuate personnel safely in Zone II, which is sufficient compared to the time for the fire to completely spread. Suggestions were made for fire safety management, such as evacuating personnel to the safety exits of other adjacent areas during a fire and installing linkage fire alarm systems in large public space s.

29 August 2024 in Fire
Verified
Journal Article
Open access
PDF file
PLPengyu Li
Pengyu Li
XBXiaohua Bao
Xiaohua Bao
Chengyu HongChengyu Hong
Chengyu Hong
DWDaochu Wang
Daochu Wang
XXXiaofeng Xie
Xiaofeng Xie
LLLonghui Liao
Longhui Liao
To explore the evacuation situation of the underground space in the Starting Area of Guangzhou International Financial City under fire, personal evacuation was simulated with Pathfinder in three zones. Then, the visual animation and the human flow rate diagram were obtained and analyzed. A fire-risk assessment model based on a combined weighting and the technique for order of preference by similarity to ideal solution (TOPSIS) is proposed to assess the fire risk of three zones. First, six second-level indices were determined from three aspects: regional safety evacuation, regional fire prevention, and regional fire extinguishment. The value of regional safety evacuation was determined by the results of the evacuation simulation. Second, the subjective and objective weights of the second-level indices were determined based on the analytic hierarchy process and entropy weight method, respectively, and a combined weighting method was adopted to reflect the subjective and objective weights. Next, TOPSIS was used to calculate the relative closeness between each scheme and the ideal scheme. The relative closeness is an evaluation index used to determine the fire-risk level of three zones. It was found that the fire-risk level of Zone Ⅰ is high, requiring large-scale rectification. The fire-risk level of Zone Ⅱ is low, and the fire toughness is strong. The fire-risk level of Zone Ⅲ is medium and needs local rectification.