Marcelo Risk

Dr. Marcelo Risk


Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2017 in Entropy
Verified
Journal Article
Open access
PDF file
FRFrancisco O Redelico
Francisco O Redelico
FVFrancisco Traversaro Varela
Francisco Traversaro Varela
MGMaría Del Carmen García
María Del Carmen García
WSWalter Silva
Walter Silva
Osvaldo RossoOsvaldo Rosso
Osvaldo Rosso
MRMarcelo Risk
Marcelo Risk
In this contribution, a comparison between different permutation entropies as classifiers of electroencephalogram (EEG) records corresponding to normal and pre-ictal states is made. A discrete probability distribution function derived from symbolization techniques applied to the EEG signal is used to calculate the Tsallis entropy, Shannon Entropy, Renyi Entropy, and Min Entropy, and they are used separately as the only independent variable in a logistic regression model in order to evaluate its capacity as a classification variable in a inferential manner. The area under the Receiver Operating Characteristic (ROC) curve, along with the accuracy, sensitivity, and specificity are used to compare the models. All the permutation entropies are excellent classifiers, with an accuracy greater than 94.5% in every case, and a sensitivity greater than 97%. Accounting for the amplitude in the symbolization technique retains more information of the signal than its counterparts, and it could be a good candidate for automatic classification of EEG signals.

1 July 2018 in Chaos: An Interdisciplinary Journal of Nonlinear Science
Verified
Journal Article
Open access
PDF file
FVFrancisco Traversaro Varela
Francisco Traversaro Varela
FRFrancisco O Redelico
Francisco O Redelico
MRMarcelo Risk
Marcelo Risk
Alejandro C. FreryAlejandro C. Frery
Alejandro C. Frery
Osvaldo RossoOsvaldo Rosso
Osvaldo Rosso
In 2002, Bandt and Pompe [Phys. Rev. Lett. 88, 174102 (2002)] introduced a successfully symbolic encoding scheme based on the ordinal relation between the amplitude of neighboring values of a given data sequence, from which the permutation entropy can be evaluated. Equalities in the analyzed sequence, for example, repeated equal values, deserve special attention and treatment as was shown recently by Zunino and co-workers [Phys. Lett. A 381, 1883 (2017)]. A significant number of equal values can give rise to false conclusions regarding the underlying temporal structures in practical contexts. In the present contribution, we review the different existing methodologies for treating time series with tied values by classifying them according to their different strategies. In addition, a novel data-driven imputation is presented that proves to outperform the existing methodologies and avoid the false conclusions pointed by Zunino and co-workers.

25 September 2002 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
EFEdmundo I. Cabrera Fischer
Edmundo I. Cabrera Fischer
ACAlejandra Christen
Alejandra Christen
MRMarcelo Risk
Marcelo Risk
FPFranco M. Pessana
Franco M. Pessana
EFEduardo De Forteza
Eduardo De Forteza

23 December 2021 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
JGJose Manuel Gallardo
Jose Manuel Gallardo
GBGiannina Bellone
Giannina Bellone
RARubén Carlos Acevedo
Rubén Carlos Acevedo
MRMarcelo Risk
Marcelo Risk
Short-term (5 min) heart rate variability analysis (HRV) demand for monitoring people's health and well-being status is increasing due to portable sensors and mobile applications. Five minutes analysis is extensive compared to that used in measurements of glucose, blood pressure, temperature, etc. To reduce costs and achieve optimal performance in personal health assessment, ultra-short-term monitoring less than 5 min is suggested. The aim of this work is to establish the minimum ultra-short-term HRV analysis time required for LF/HF (LH) (frequency domain sympathy-vagal balance indicator) and SD21 (Poincare graphic domain sympathy-vagal balance indicator) to be equivalent to those obtained by 5 min HRV. From electrocardiograms (ECGs), processing of 23 subjects in the experiment and series of 60, 90, 120, 180, 240 and 300 s (5 min) were obtained. The HRV time series was calculated and each LH and SD21 indicator in each of the ultra-short series was compared with the 300 s (Gold Standard), using different concordance analysis methods, such us Pearson correlation, Bland Altman, Cohen Delta. The ultra-short-term HRV LH indicator is equivalent to short-term HRV (5 min) in series equal or greater than 180 s while SD21 was equivalent to series equal or greater than 120 s.

22 August 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Marcos F. BamonteMarcos F. Bamonte
Marcos F. Bamonte
MRMarcelo Risk
Marcelo Risk
Victor Angel HerreroVictor Angel Herrero
Victor Angel Herrero
Automatic emotion recognition using portable sensors is gaining attention due to its potential use in real-life scenarios. Existing studies have not explored Galvanic Skin Response and Photoplethysmography sensors exclusively for emotion recognition using nonlinear features with machine learning (ML) classifiers such as Random Forest, Support Vector Machine, Gradient Boosting Machine, K-Nearest Neighbor, and Decision Tree. In this study, we proposed a genuine window sensitivity analysis on a continuous annotation dataset to determine the window duration and percentage of overlap that optimize the classification performance using ML algorithms and nonlinear features, namely, Lyapunov Exponent, Approximate Entropy, and Poincaré indices. We found an optimum window duration of 3 s with 50% overlap and achieved accuracies of 0.75 and 0.74 for both arousal and valence, respectively. In addition, we proposed a Strong Labeling Scheme that kept only the extreme values of the labels, which raised the accuracy score to 0.94 for arousal. Under certain conditions mentioned, traditional ML models offer a good compromise between performance and low computational cost. Our results suggest that well-known ML algorithms can still contribute to the field of emotion recognition, provided that window duration, overlap percentage, and nonlinear features are carefully selected.

13 January 2021 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
JGJose Gallardo
Jose Gallardo
GBGiannina Bellone
Giannina Bellone
SPSantiago Plano
Santiago Plano
DVDaniel Eduardo Vigo
Daniel Eduardo Vigo
MRMarcelo Risk
Marcelo Risk