The migration of light non-aqueous phase liquids (LNAPLs) trapped in porous media is a complex phenomenon. Groundwater table fluctuation can not only affect contaminant migration but also redox conditions, bacterial communities, and contaminant degradation. Understanding LNAPLs’ (e.g., benzene, toluene, ethylbenzene, and xylene (BTEX)) behavior within porous media is critical for the high efficiency of most in situ remediation systems. A laboratory study of single- and double-lithology soil column investigation of the groundwater table fluctuation effect on BTEX transport, using benzene and toluene as typical compounds, in a typical representative model of aquifers subjected to water table fluctuation was undertaken in this study. The results show that benzene and toluene migration in single-lithology soil columns packed with sand was mainly affected by flushing due to the hydraulic force induced by water table fluctuations and that the double-lithology soil column packed with sand and silt was significantly affected by retention due to the higher adsorption induced by 10 cm of silt. The dissolution mainly correlated with the BTEX migration in saturated zones, and the contaminant concentration increased when the water table fell and decreased when the water table rose. For a contaminated site with a single-lithology structure consisting of sand, more attention should be paid to organic contaminant removal within the groundwater, and a double-lithology structure containing silt is more suited to the removal of organic contaminants from the silt layer. The difference in biodegradation kinetics between the groundwater table fluctuation (GTF) zone and the saturated zone should be better understood for the remediation of BTEX compounds.
The effects of groundwater table fluctuation (GTF) on the remediation of a petrochemically polluted riverside using soil vapor extraction (SVE) were investigated. The migration and transformation of benzene, toluene, ethylbenzene, and o-xylene (BTEX) in cases of natural attenuation, SVE without GTF, and SVE with GTF were simulated using the TMVOC model. The results showed that the optimized extraction well pressure and influencing radius of the target site were 0.90 atm and 8 m, respectively. The removal rates of BTEX in cases of natural attenuation, SVE without GTF, and SVE with GTF were 11.49%, 85.16%, and 97.33%, respectively. The removal rate of BTEX was maximized in the case of SVE with a GTF amplitude of 0.5 m to 1 m. The removal rates of benzene (99.99%), toluene (99.74%), ethylbenzene (96.37%), and o-xylene (94.72%) were maximized in the case of SVE with GTF. For the cases of SVE without GTF and SVE with GTF, mass losses of BTEX in gaseous (0.05 kg, 0.05 kg, respectively) and aqueous phases (5.46 kg, 5.87 kg, respectively) were consistent. However, the mass loss of BTEX in the non-aqueous phase liquid (NAPL) phase in the case of SVE with GTF (155.13 kg) exceeded that in the case of SVE without GTF (135.41 kg). This is because GTF positively affected both the solubility and volatility of BTEX in the NAPL phase. With the groundwater table decreasing, flows of gas and gaseous pollutants increased by 25% along the vertical section. At this stage, the removal rates of volatile organic compounds can be further improved by increasing the flow of the extraction well.