Lili Zou

Dr. Lili Zou

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2022 in Talanta
Verified
Journal Article
Closed access
QLQian Lv
Qian Lv
LCLong-Sheng Chen
Long-Sheng Chen
HLHai-Xin Liu
Hai-Xin Liu
LZLili Zou
Lili Zou

6 May 2022 in Frontiers in Neuroscience
Verified
Journal Article
Open access
HJHengbing Jiang
Hengbing Jiang
LZLili Zou
Lili Zou
DHDequn Huang
Dequn Huang
QFQianjin Feng
Qianjin Feng
In this article, a novel method for continuous blood pressure (BP) estimation based on multi-scale feature extraction by the neural network with multi-task learning (MST-net) has been proposed and evaluated. First, we preprocess the target (Electrocardiograph; Photoplethysmography) and label signals (arterial blood pressure), especially using peak-to-peak time limits of signals to eliminate the interference of the false peak. Then, we design a MST-net to extract multi-scale features related to BP, fully excavate and learn the relationship between multi-scale features and BP, and then estimate three BP values simultaneously. Finally, the performance of the developed neural network is verified by using a public multi-parameter intelligent monitoring waveform database. The results show that the mean absolute error ± standard deviation for systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) with the proposed method against reference are 4.04 ± 5.81, 2.29 ± 3.55, and 2.46 ± 3.58 mmHg, respectively; the correlation coefficients of SBP, DBP, and MAP are 0.96, 0.92, and 0.94, respectively, which meet the Association for the Advancement of Medical Instrumentation standard and reach A level of the British Hypertension Society standard. This study provides insights into the improvement of accuracy and efficiency of a continuous BP estimation method with a simple structure and without calibration. The proposed algorithm for BP estimation could potentially enable continuous BP monitoring by mobile health devices.

21 December 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
KMKe Ma
Ke Ma
LZLili Zou
Lili Zou
FYFeng Yang
Feng Yang
CZChang'AN A. Zhan
Chang'AN A. Zhan
YGYao Gong
Yao Gong
DHDequn Huang
Dequn Huang

28 December 2022 in Reproductive Sciences
Verified
Journal Article
Closed access
PDF file
ZYZerui Yang
Zerui Yang
JLJunren Li
Junren Li
YTYubo Tang
Yubo Tang
LZLili Zou
Lili Zou

15 July 2025 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
SYShengnan Ya
Shengnan Ya
LWLichao Wang
Lichao Wang
HTHang Tian
Hang Tian
LZLili Zou
Lili Zou
XLXiangsong Lin
Xiangsong Lin
Chengyi HouChengyi Hou
Chengyi Hou
A wearable sweat sensor for ascorbic acid detection was developed based on N-rGO-loaded Ni3N/Ni heterostructure. The device enabled the detection of ascorbic acid concentration, highlighting its promise for non-invasive health monitoring.

18 August 2023 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
KTKaiyue Tan
Kaiyue Tan
LCLongsheng Chen
Longsheng Chen
DCDonglin Cao
Donglin Cao
WXWei Xiao
Wei Xiao
QLQian Lv
Qian Lv
LZLili Zou
Lili Zou
As a promising biomarker of liquid biopsy, circulating tumor DNA (ctDNA) plays a paramount role in the early diagnosis of noninvasive cancer. The isothermal catalytic hairpin assembly (CHA) strategy has great potential for in vitro detection of ctDNA in low abundance. However, a traditional CHA strategy for ctDNA detection at the earlier stages of cancer remains extremely challenging, as annoying signal leakage from the ‘breathing’ phenomenon and nuclease degradation occur. Herein, we report a locked nucleic acid (LNA)-incorporated CHA circuit for the rapid and sensitive detection of target ctDNA. The target ctDNA intelligently catalyzed LNA-modified hairpins H1 and H2via a range of toehold-mediated strand displacement processes, leading to the continuous generation of an H1–H2 hybrid for the amplified fluorescence signal. In comparison to conventional CHA circuits, the stronger binding affinity of LNA–DNA bases greatly inhibited the breathing effect, which endowed it with greater thermodynamic stability and resistance to nuclease degradation in the LNA-assisted CHA system, thus achieving a high signal gain. The developed CHA circuit demonstrated excellent performance during target ctDNA detection, with a linear range from 10 pM to 5 nM, and its target detection limit was reached at 3.3 pM. Moreover, this LNA-assisted CHA system was successfully applied to the analysis of target ctDNA in clinical serum samples of breast cancer patients. This updated CHA system provides a general and robust platform for the sensitive detection of biomarkers of interest, thus facilitating the accurate identification and diagnosis of cancers.