Mafalda Sarraguça

Dr. Mafalda Sarraguça

LAQV@REQUIMTE, Porto, Portugal
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2024 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
Cátia FerreiraCátia Ferreira
Cátia Ferreira
Mafalda SarraguçaMafalda Sarraguça
Mafalda Sarraguça
The extraction of bioactive compounds of pharmaceutical interest from natural sources has been significantly explored in recent decades. However, the extraction techniques used were not very efficient in terms of time and energy consumption; additionally, the solvents used for the extraction were harmful for the environment. To improve the environmental impact of the extractions and at the same time increase the extraction yields, several new extraction techniques were developed. Among the most used ones are ultrasound-assisted extraction and microwave-assisted extraction. These extraction techniques increased the yield and selectivity of the extraction in a smaller amount of time with a decrease in energy consumption. Nevertheless, a high volume of organic solvents was still used for the extraction, causing a subsequent environmental problem. Neoteric solvents appeared as green alternatives to organic solvents. Among the neoteric solvents, deep eutectic solvents were evidenced to be one of the best alternatives to organic solvents due to their intrinsic characteristics. These solvents are considered green solvents because they are made up of natural compounds such as sugars, amino acids, and carboxylic acids having low toxicity and high degradability. In addition, they are simple to prepare, with an atomic economy of 100%, with attractive physicochemical properties. Furthermore, the huge number of compounds that can be used to synthesize these solvents make them very useful in the extraction of bioactive compounds since they can be tailored to be selective towards a specific component or class of components. The main aim of this paper is to give a comprehensive review which describes the main properties, characteristics, and production methods of deep eutectic solvents as well as its application to extract from natural sources bioactive compounds with pharmaceutical interest. Additionally, an overview of the more recent and sustainable extraction techniques is also given.

30 May 2012 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
Nídia Dana LourençoNídia Dana Lourenço
Nídia Dana Lourenço
Joao LopesJoao Lopes
Joao Lopes
CAC. F. Almeida
C. F. Almeida
Mafalda SarraguçaMafalda Sarraguça
Mafalda Sarraguça
HPHelena Maria Pinheiro
Helena Maria Pinheiro

1 August 2018 in International Journal of Pharmaceutics
Verified
Journal Article
Closed access
MRMarisa Rodrigues
Marisa Rodrigues
BBBárbara Baptista
Bárbara Baptista
JLJoão Almeida Lopes
João Almeida Lopes
Mafalda SarraguçaMafalda Sarraguça
Mafalda Sarraguça

25 February 2014 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
RMR. Matias
R. Matias
PRPaulo Roberto da Silva Ribeiro
Paulo Roberto da Silva Ribeiro
Mafalda SarraguçaMafalda Sarraguça
Mafalda Sarraguça
Joao LopesJoao Lopes
Joao Lopes
Folic acid (FA) or pteroyl-L-glutamic acid, chemically known as N-[4-[[(2-amino-1,4-dihydro-4-oxo-6-pteridinyl)methyl]amino]benzoyl]-L-glutamic acid, is a water-soluble B vitamin that helps build healthy cells. In this study, a new, simple, easy, accurate, precise, economic and sensitive UV spectrophotometric method for the determination of folic acid in commercial tablets and during dissolution tests is presented. Using a phosphate buffer solution at pH 9.0 it was possible to determine the concentration of folic acid in commercial tablets at a λmax of 282.5 nm in a linear range of 1.0–17.5 μg ml−1 with a R2 > 0.9999 and recovery between 100.6 and 101.1%. The method was also optimized for the quantification of folic acid in dissolution tests in the same linear concentration range. The pH effect on the UV spectra of folic acid solutions was eliminated with a first derivative. This procedure allowed the direct measurement of samples from the dissolution vessel (pH approximately equal to 6) without any pH correction. This method was based on the first derivative of the absorbance at λ = 377.2 nm, yielding an R2 > 0.9997 with recovery percentages similar to those presented before. The statistical comparison between the proposed and the HPLC reference method showed excellent agreement and indicates no statistically significant difference in accuracy and precision at a 0.05 significance level.

1 December 2012 in Food Chemistry
Verified
Journal Article
Closed access
João Rodrigo SantosJoão Rodrigo Santos
João Rodrigo Santos
Mafalda SarraguçaMafalda Sarraguça
Mafalda Sarraguça
António RangelAntónio Rangel
António Rangel
Joao LopesJoao Lopes
Joao Lopes

1 March 2009 in Vibrational Spectroscopy
Verified
Journal Article
Closed access
Mafalda SarraguçaMafalda Sarraguça
Mafalda Sarraguça
Joao LopesJoao Lopes
Joao Lopes