Fang Lin

Dr. Fang Lin

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2023 in Tunnelling and Underground Space Technology
Verified
Journal Article
Closed access
FLFang Lin
Fang Lin
XYXiuren Yang
Xiuren Yang

1 January 2019 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
XYXiuren Yang
Xiuren Yang
ZSZhongheng Shi
Zhongheng Shi
FLFang Lin
Fang Lin
Prefabricated underground structures were first researched in China to address the serious social and environmental issues associated with underground construction. Five metro stations have been built on Line 2 of the Changchun Metro in China using this new prefabrication technology. The joints connecting prefabricated elements are the most critical components in such prefabricated structures. In this study, experiments and numerical simulations investigating the influences of different grouted mortise and tenon joint geometrical parameters were conducted to determine the optimal parameters and ensure proper performance. To do so, a finite element model was built with the appropriate characteristics using the experimental results, and an analysis of the influence of different geometrical parameters was conducted. The results indicate that increasing the dip angle of the tenon could improve the flexural rigidity of the joint, but its effect was relatively small compared to that of the other parameters. Increasing the width of the tenon only had a positive effect on the flexural rigidity of the joint when the width was relatively small and under small axial loads. Increasing the length of the tenon helped to enhance the flexural performance of the joint; however, this advantage was not obvious when the tenon length was relatively long. Proper indentation of the joint improved the flexural capacity under a small axial load, but was not beneficial under a high axial load. The findings of this study are of value to help researchers and engineers more effectively design prefabricated underground structures.

17 October 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HENG ZHANGHENG ZHANG
HENG ZHANG
JSJianchun SUN
Jianchun SUN
FLFang Lin
Fang Lin
SCShougen Chen
Shougen Chen
JYJiasong Yang
Jiasong Yang
The ventilation effect has a direct influence on the efficiency and security of the construction of an underground cavern group. Traditional forced ventilation schemes may be ineffective and result in resource wastage. Based on the construction ventilation of the Jinzhou underground oil storage project, an axial flow gallery ventilation mode using shafts as the fresh air inlet was proposed. A 3D steady RANS (Reynolds Averaged Navier-Stokes) approach with the RNG (Renormalization-group) k-ε turbulence model was used to study airflow behavior and hazardous gas dispersion when different ventilation schemes were employed. Field test values of the air velocity and CO concentration in the main cavern and construction roadway were also adopted to validate the RNG k-ε turbulence model. The results showed that the axial flow gallery ventilation mode can ensure that the direction of air flow is the same as that of heavy trucks, fresh air is always near the excavation face, and the disturbance of the construction process is greatly reduced. The scheme is suitable for large-scale caverns with a ventilation distance less than 2 km, and an intermediate construction shaft is not needed. When the ventilation distance exceeds 2 km, it is possible to use jet fans to assist the axial flow gallery ventilation mode or to completely adopt jet-flow gallery ventilation.

1 January 2021 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
XYXiuren Yang
Xiuren Yang
FLFang Lin
Fang Lin
MHMeiqun Huang
Meiqun Huang
The grouted mortise‐tenon joint, invented as the connection between the large prefabricated components, is the key to the prefabricated underground structures, and the double‐tenon joint is most widely used in the prefabricated metro station structure. This paper conducts characteristic analysis of bending stiffness with a 1 : 1 prototype test in key working direction of different joint types for grouted double mortise‐tenon joint. The results show that the double‐tenon joint is characteristic of variable stiffness under different loads. Change laws of double‐tenon joint bending stiffness without and with auxiliary pretightening device in tension side and compression side are also discussed. The correlations for calculating double‐tenon joint bending stiffness with various axial loads and bending moments are derived at last, which offers the theory foreshadowing of similar joints.

12 November 2019 in Advances in Materials Science and Engineering
Verified
Journal Article
Open access
PDF file
XYXiuren Yang
Xiuren Yang
ZSZhongheng Shi
Zhongheng Shi
FLFang Lin
Fang Lin
The MT·G-Joint (grouted mortise-tenon joint), invented as the connection between the large prefabricated elements, is the most important component in the prefabricated underground structures. Its shear performance is critical to the overall mechanical performance of the prefabricated structure. This paper carries out four-point pure shear experiment to investigate the shear performance of the MT·G-Joint. The shear key method is then proved to be suitable for MT·G-Joint when the axial load is 0 kN based on the experimental results. In addition, combining the shear key method and experimental results, the calculation method of the shear capacity, improved shear key method (ISKM), is proposed on account of the mechanical model of the failure plane. ISKM is appropriate for different load conditions. Finally, every kind of joints used in the prefabricated metro station structures on Changchun Metro Line 2 is calculated by using ISKM. The results indicate that the shear capacity of the MT·G-Joint is good, and the used joints still have large safety margin even under the worst working condition. The findings of this study are of value to help researchers and engineers more effectively design prefabricated underground structures.

1 January 2021 in Advances in Civil Engineering
Verified
Journal Article
Open access
PDF file
XYXiuren Yang
Xiuren Yang
FLFang Lin
Fang Lin
MHMeiqun Huang
Meiqun Huang
The grouted mortise‐tenon joint, invented as the connection between the large prefabricated elements, is the most important component in the prefabricated underground structures. This paper conducts analysis of load‐carrying capacity performance and failure mode with 1 : 1 prototype test in key working direction of different double mortise‐tenon joint types for the prefabricated metro station. The resistance moment is developed and used to analyze the bending bearing characteristic curve, and the corresponding test results of each stage of the characteristic curve are described in detail. In addition, the bending bearing performance of different types of double‐tenon joints under different load conditions is compared. The test results clarify the ultimate failure mode of double‐tenon joint and the variable bearing capacity characteristics of the joint with the increase in axial load and explain the bearing performance of each stage. It is also found the auxiliary pretightening device is helpful to delay the appearance of cracks and improve the bearing capacity, especially when it is set on the tension side. The research results have important application value for the joint design of prefabricated metro station structures.