This paper presents a comprehensive investigation of the various parameters involved in the fabrication of a molecularly imprinted polymer (MIP) sensor for the detection of cortisol. Parameters such as monomer concentration, electropolymerization cycles, pH, monomer–template ratio, template removal technique, and rebinding time were optimized to establish a more consistent and effective method for the fabrication of MIP sensors. Under the optimized conditions, the MIP sensor demonstrated a proportional decrease in differential pulse voltammetry peak currents with increasing cortisol concentration in the range of 0.1 to 100 nM. The sensor exhibited excellent sensitivity, with a limit of detection of 0.036 nM. Selectivity experiments using a non-imprinted polymer sensor confirmed the specific binding affinity of the MIP sensor for cortisol, distinguishing it from other steroid hormones. This study provides crucial insights into the development of a reliable and sensitive strategy for cortisol detection using O-PD-based MIPs. These findings laid the foundation for further advancements in MIP research.
Chlorpyrifos (CPF) is widely used as an organophosphorus insecticide; however, owing to developmental neurotoxicity, genotoxicity, and other adverse effects, it is harmful not only to livestock but also to humans. Therefore, the use of CPF was recently regulated, and its sensitive detection is crucial, as it causes serious toxicity, even in the case of residual pesticides. Because it is hard to detect the chlorpyrifos directly using spectroscopy (especially in SERS) without chemical reagents, we aimed to develop a SERS platform that could detect the chlorpyrifos directly in the water. In this study, we utilized the intrinsic properties of natural lawns that grow randomly and intertwine with each other to have a large surface area to promote photosynthesis. To detect CPF sensitively, we facilitated the rapid fabrication of biomimetic Ag nanograss (Ag-NG) as a surface-enhanced Raman spectroscopy (SERS) substrate using the electrochemical over-deposition method. The efficiency of the SERS method was confirmed through experiments and finite element method (FEM)-based electromagnetic simulations. In addition, the sensitive detection of CPF was enhanced by pretreatment optimization of the application of the SERS technique (limit of detection: 500 nM). The Ag-NG has potential as a SERS platform that could precisely detect organic compounds, as well as various toxic substances.