Luis Scheiner

Luis Scheiner

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2023 in Life
Verified
Journal Article
Open access
PDF file
BWBenjamin Weixler
Benjamin Weixler
LLLeonard A. Lobbes
Leonard A. Lobbes
LSLuis Scheiner
Luis Scheiner
Johannes Christian LauscherJohannes Christian Lauscher
Johannes Christian Lauscher
SSSebastian Manuel Staubli
Sebastian Manuel Staubli
DRDimitri Aristotle Raptis
Dimitri Aristotle Raptis
Introduction: Successful R0 resection is crucial for the survival of patients with primary liver cancer (PLC) or liver metastases. Up to date, surgical resection lacks a sensitive, real-time intraoperative imaging modality to determine R0 resection. Real-time intraoperative visualization with near-infrared light fluorescence (NIRF) using indocyanine green (ICG) may have the potential to meet this demand. This study evaluates the value of ICG visualization in PLC and liver metastases surgery regarding R0 resection rates. Materials and Methods: Patients with PLC or liver metastases were included in this prospective cohort study. ICG 10 mg was administered intravenously 24 h before surgery. Real-time intraoperative NIRF visualization was created with the SpectrumTM fluorescence imaging camera system. First, all liver segments were inspected with the fluorescence imaging system and intraoperative ultrasound for identification of the known tumor, as well as additional lesions, and were compared to preoperative MRI images. PLC, liver metastases, and additional lesions were then resected according to oncological principles. In all resected specimens, the resection margins were analyzed with the fluorescence imaging system for ICG-positive spots immediately after resection. Histology of additional detected lesions, as well as ICG fluorescence compared to histological resection margins, were assessed. Results: Of the 66 included patients, median age was 65.5 years (IQR 58.7–73.9), 27 (40.9%) were female, and 18 (27.3%) were operated on laparoscopically. Additional ICG-positive lesions were detected in 23 (35.4%) patients, of which 9 (29%) were malignant. In patients with no fluorescent signal at the resection margin, R0 rate was 93.9%, R1 rate was 6.1%, and R2 rate was 0% compared to an ICG-positive resection margin with an R0 rate of 64.3%, R1 rate of 21.4%, and R2 rate of 14.3% (p = 0.005). One- and two-year overall survival rates were 95.2% and 88.4%, respectively. Conclusion: The presented study provides significant evidence that ICG NIRF guidance helps to identify R0 resection intraoperatively. This offers true potential to verify radical resection and improve patient outcomes. Furthermore, implementation of NIRF-guided imaging in liver tumor surgery allows us to detect a considerable amount of additional malignant lesions.

11 April 2023 in Preprints.org
Verified
Preprint
Open access
BWBenjamin Weixler
Benjamin Weixler
LLLeonard A. Lobbes
Leonard A. Lobbes
LSLuis Scheiner
Luis Scheiner
Johannes Christian LauscherJohannes Christian Lauscher
Johannes Christian Lauscher
SSSebastian M. Staubli
Sebastian M. Staubli
DRDimitri A. Raptis
Dimitri A. Raptis
Introduction: Successful R0 resection is crucial for the survival of patients with primary liver cancer (PLC) or liver metastases. Up to date, surgical resection lacks a sensitive, real-time intraoperative imaging modality to determine R0 resection. Real-time intraoperative visualization with near-infrared light fluorescence (NIRF) using indocyanine green (ICG) may have the potential to meet this demand. This study evaluates the value of ICG visualization in PLC and liver metastases surgery regarding R0 resection rates. Materials and Methods Patients with PLC or liver metastases were included in this prospective cohort study. ICG 10mg was administered intravenously 24 hours before surgery. Real-time intraoperative NIRF visualization was made with the SpectrumTM Fluorescence Imaging Camera System. First, all liver segments were inspected with the fluorescence imaging system and intraoperative ultrasound for identification of the known tumor as well as additional lesions, compared to preoperative MRI. PLC, liver metastases, and additional lesions were then resected according to oncological principles. Of all resected specimens the resection margins were analyzed with the fluorescence imaging system for ICG positive spots right after resection. Histology of additional detected lesions as well as ICG fluorescence compared to histological resection margins were assessed. Results Of the 66 included patients median age was 65.5 years (IQR 58.7 - 73.9), 27 (40.9%) were female and 18 (27.3%) were operated laparoscopically. Additional ICG positive lesions were detected in 23 (35.4%) patients of which nine (29%) were malignant. In patients with no fluorescent signal at the resection margin, R0 rate was 93.9%, R1 rate was 6.1%, and R2 rate was 0% compared to a ICG positive resection margin with a R0 rate of 64.3%, R1 rate of 21.4%, and R2 rate of 14.3% (p=0.005). One and two year overall survival were 95.2% and 88.4%, respectively. Conclusion The here presented study provides significant evidence that ICG NIRF guidance helps to identify R0 resection intraoperatively. This offers a true potential to verify radical resection and improve patients´ outcome. Furthermore, implementation of NIRF guided imaging in liver tumor surgery allows to detect a considerable amount of additional malignant lesions.