Objective . This work describes an approach for producing physical anthropomorphic breast phantoms from clinical patient data using three-dimensional (3D) fused-deposition modelling (FDM) printing. Approach . The source of the anthropomorphic model was a clinical Magnetic Resonance Imaging (MRI) patient image set, which was segmented slice by slice into adipose and glandular tissues, skin and tumour formations; thus obtaining a four component computational breast model. The segmented tissues were mapped to specific Hounsfield Units (HU) values, which were derived from clinical breast Computed Tomography (CT) data. The obtained computational model was used as a template for producing a physical anthropomorphic breast phantom using 3D printing. FDM technology with only one polylactic acid filament was used. The physical breast phantom was scanned at Siemens SOMATOM Definition CT. Quantitative and qualitative evaluation were carried out to assess the clinical realism of CT slices of the physical breast phantom. Main results . The comparison between selected slices from the computational breast phantom and CT slices of the physical breast phantom shows similar visual x-ray appearance of the four breast tissue structures: adipose, glandular, tumour and skin. The results from the task-based evaluation, which involved three radiologists, showed a high degree of realistic clinical radiological appearance of the modelled breast components. Measured HU values of the printed structures are within the range of HU values used in the computational phantom. Moreover, measured physical parameters of the breast phantom, such as weight and linear dimensions, agreed very well with the corresponding ones of the computational breast model. Significance . The presented approach, based on a single FDM material, was found suitable for manufacturing of a physical breast phantom, which mimics well the 3D spatial distribution of the different breast tissues and their x-ray absorption properties. As such, it could be successfully exploited in advanced x-ray breast imaging research applications.
This paper presents a method for creation of computational models of breast lesions with irregular shapes from patient Digital Breast Tomosynthesis (DBT) images or breast cadavers and whole-body Computed Tomography (CT) images. The approach includes six basic steps: (a) normalization of the intensity of the tomographic images; (b) image noise reduction; (c) binarization of the lesion area, (d) application of morphological operations to further decrease the level of artefacts; (e) application of a region growing technique to segment the lesion; and (f) creation of a final 3D lesion model. The algorithm is semi-automatic as the initial selection of the region of the lesion and the seeds for the region growing are done interactively. A software tool, performing all of the required steps, was developed in MATLAB. The method was tested and evaluated by analysing anonymized sets of DBT patient images diagnosed with lesions. Experienced radiologists evaluated the segmentation of the tumours in the slices and the obtained 3D lesion shapes. They concluded for a quite satisfactory delineation of the lesions. In addition, for three DBT cases, a delineation of the tumours was performed independently by the radiologists. In all cases the abnormality volumes segmented by the proposed algorithm were smaller than those outlined by the experts. The calculated Dice similarity coefficients for algorithm-radiologist and radiologist-radiologist showed similar values. Another selected tumour case was introduced into a computational breast model to recursively assess the algorithm. The relative volume difference between the ground-truth tumour volume and the one obtained by applying the algorithm on the synthetic volume from the virtual DBT study is 5% which demonstrates the satisfactory performance of the proposed segmentation algorithm. The software tool we developed was used to create models of different breast abnormalities, which were then stored in a database for use by researchers working in this field.
In recent years, material extrusion-based additive manufacturing, particularly fused filament fabrication (FFF), has gained significant attention due to its versatility and cost-effectiveness in producing complex geometries. This paper presents the characterization of seven novel materials for FFF and twenty-two commercially available filaments in terms of X-ray computed tomography (CT) numbers, as tissue mimicking materials for the realization of 3D printed radiological phantoms. Two technical approaches, by 3D printing of cube samples and by producing cylinders of melted materials, are used for achieving this goal. Results showed that the CT numbers, given in Hounsfield unit (HU), of all the samples depended on the beam kilovoltage (kV). The CT numbers ranged from +411 HU to +3071 HU (at 80 kV), from −422 HU to +3071 HU (at 100 kV), and from −442 HU to +3070 HU (at 120 kV). Several commercial and custom-made filaments demonstrated suitability for substituting soft and hard human tissues, for realization of 3D printed phantoms with FFF in CT imaging. For breast imaging, an anthropomorphic phantom with two filaments could be fabricated using ABS-C (conductive acrylonitrile butadiene styrene) as a substitute for breast adipose tissue, and ASA-A (acrylic styrene acrylonitrile) for glandular breast tissue.
High efficiency is among the most important targets in power electronic converters. A possible approach to obtain this goal is the usage of better switches. This paper is focused at the study and comparison of SiC and Si power MOSFETS in soft switching resonant DC/DC converter. The latter converter being a part of light battery charger used in ultra-light electric vehicles is realized and investigated. The losses in the power switches are compared mathematically, with simulations and experimental verification. Two types of transistors are considered. First traditional state of the art Si-technology using a FREDFET (fast recovery diode MOSFET) and it is compared with what the SiC technology offers, using a fast Schottky antiparallel diode. As an example a 1500 W series resonance converter with input voltage of 400 V and output voltage of 100 V is used. The latter voltage permitting the use of Schottky diodes at the secondary side. The losses in both converters are compared via calorimetic measurements to avoid accuracy problems as in loss measurements with an oscilloscope for example.