Ryan Chapman

Dr. Ryan Chapman

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
RCRyan Chapman
Ryan Chapman
WMWayne E. Moschetti
Wayne E. Moschetti
DCDouglas W. Van Citters
Douglas W. Van Citters

13 February 2019 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
RCRyan Chapman
Ryan Chapman
MTMichael T. Torchia
Michael T. Torchia
JBJohn-Erik Bell
John-Erik Bell
DCDouglas W. Van Citters
Douglas W. Van Citters
Current shoulder clinical range of motion (ROM) assessments (e.g., goniometric ROM) may not adequately represent shoulder function beyond controlled clinical settings. Relative inertial measurement unit (IMU) motion quantifies ROM precisely and can be used outside of clinic settings capturing “real-world” shoulder function. A novel IMU-based shoulder elevation quantification method was developed via IMUs affixed to the sternum/humerus, respectively. This system was then compared to in-laboratory motion capture (MOCAP) during prescribed motions (flexion, abduction, scaption, and internal/external rotation). MOCAP/IMU elevation were equivalent during flexion (R2 = 0.96, μError = 1.7 deg), abduction (R2 = 0.96, μError = 2.9 deg), scaption (R2 = 0.98, μError = −0.3 deg), and internal/external rotation (R2 = 0.90, μError = 0.4 deg). When combined across movements, MOCAP/IMU elevation were equal (R2 = 0.98, μError = 1.4 deg). Following validation, the IMU-based system was deployed prospectively capturing continuous shoulder elevation in 10 healthy individuals (4 M, 69 ± 20 years) without shoulder pathology for seven consecutive days (13.5 ± 2.9 h/day). Elevation was calculated continuously daily and outcome metrics included percent spent in discrete ROM (e.g., 0–5 deg and 5–10 deg), repeated maximum elevation (i.e., >10 occurrences), and maximum/average elevation. Average elevation was 40 ± 6 deg. Maximum with >10 occurrences and maximum were on average 145–150 deg and 169 ± 8 deg, respectively. Subjects spent the vast majority of the day (97%) below 90 deg of elevation, with the most time spent in the 25–30 deg range (9.7%). This study demonstrates that individuals have the ability to achieve large ROMs but do not frequently do so. These results are consistent with the previously established lab-based measures. Moreover, they further inform how healthy individuals utilize their shoulders and may provide clinicians a reference for postsurgical ROM.

1 February 2016 in Clinical Biomechanics
Verified
Journal Article
Closed access
TGTimothy C. Gribbin
Timothy C. Gribbin
LSLindsay V. Slater
Lindsay V. Slater
CHC. Collin Herb
C. Collin Herb
JHJoseph M. Hart
Joseph M. Hart
RCRyan Chapman
Ryan Chapman
CKChristopher M. Kuenze
Christopher M. Kuenze

1 August 2019 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
RCRyan Chapman
Ryan Chapman
MTMichael T. Torchia
Michael T. Torchia
JBJohn-Erik Bell
John-Erik Bell
DCDouglas W. Van Citters
Douglas W. Van Citters

30 June 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MMMegan McCabe
Megan McCabe
DCDouglas W Van Citters
Douglas W Van Citters
RCRyan Chapman
Ryan Chapman
End-stage hip joint osteoarthritis treatment, known as total hip arthroplasty (THA), improves satisfaction, life quality, and activities of daily living (ADL) function. Postoperatively, evaluating how patients move (i.e., their kinematics/kinetics) during ADL often requires visits to clinics or specialized biomechanics laboratories. Prior work in our lab and others have leveraged wearables and machine learning approaches such as artificial neural networks (ANNs) to quantify hip angles/moments during simple ADL such as walking. Although level-ground ambulation is necessary for patient satisfaction and post-THA function, other tasks such as stair ascent may be more critical for improvement. This study utilized wearable sensors/ANNs to quantify sagittal/frontal plane angles and moments of the hip joint during stair ascent from 17 healthy subjects. Shin/thigh-mounted inertial measurement units and force insole data were inputted to an ANN (2 hidden layers, 10 total nodes). These results were compared to gold-standard optical motion capture and force-measuring insoles. The wearable-ANN approach performed well, achieving rRMSE = 17.7% and R2 = 0.77 (sagittal angle/moment: rRMSE = 17.7 ± 1.2%/14.1 ± 0.80%, R2 = 0.80 ± 0.02/0.77 ± 0.02; frontal angle/moment: rRMSE = 26.4 ± 1.4%/12.7 ± 1.1%, R2 = 0.59 ± 0.02/0.93 ± 0.01). While we only evaluated healthy subjects herein, this approach is simple and human-centered and could provide portable technology for quantifying patient hip biomechanics in future investigations.

1 September 2021 in Medicine in Novel Technology and Devices
Verified
Journal Article
Open access
RCRyan Chapman
Ryan Chapman
WMWayne E. Moschetti
Wayne E. Moschetti
DCDouglas W. Van Citters
Douglas W. Van Citters