In a deep geological disposal system, bentonite buffer material is an important barrier used to protect the disposal canister from the inflow of groundwater and prevent the outflow of radionuclides. This study aimed to characterize the mineralogical and chemical reactions of bentonite caused by copper corrosion of the canister in a radioactive waste repository. We investigated the d-spacings of montmorillonite in Gyeongju bentonite (Ca-type, KJ-I) under groundwater-saturated conditions over 10 years and compared their characteristics with those of Wyoming bentonite (Na-type, MX-80) in the Korea Atomic Energy Research Institute Underground Research Tunnel. Mineralogical investigations using X-ray diffraction and focused ion beam energy-dispersive spectroscopy indicated that no transformation of smectite or neo-formed clay phases occurred. In the Ca-type bentonite (KJ-I), the swelling was observed when it was in contact with rolled plate (RP) and cold-spray-coated (CSC) copper, with d-spacing expansions of 2.9% and 3.8%, respectively. In contrast, the Na-type bentonite (MX-80) showed d-spacing expansions of 17.6% and 19.6% when it was in contact with the RP and CSC Cu, respectively. The Cu concentration and distribution indicated that the corrosion products dissolved and then diffused into the surrounding bentonite, with maximum penetration depths of 2.0 and 0.5 mm over 10 years, respectively.
Corrosion modules simulating the engineered barrier system were designed for long-term corrosion (LTC) testing of canister materials under aerobic and anaerobic conditions. The LTC module for aerobic conditions was designed as a bath-type container flowing underground water from Korea Underground Research Tunnel. Rolled Cu, stainless steel 304 (SS), Ti-grade 2, cast iron, and Cu coatings were embedded into bentonites. After three years of testing under aerobic conditions, the corrosion rate of Cu was estimated to be 550 nm/year. The LTC module for anaerobic conditions was developed in a vessel-type cylindrical container to settle into boreholes. Four coin-shaped samples of each metal were embedded in bentonite, which was subsequently stacked in a cylindrical vessel. The vessels were placed in boreholes at a depth of 300 m. Retrieving modules at an early stage of the LTC test for six months under anaerobic conditions revealed a Cu corrosion rate of 280 nm/year.