The static and dynamic characteristics of SiC MOSFETs under gate and drain biases exhibit differential degradation after irradiation. Total ionizing dose (TID) irradiation caused threshold voltage shift and switch response degradation, and the degradation trends of these two parameters were not the same dependence on the bias. The threshold voltage of devices under test (DUT) shifted toward negative due to the radiation-induced positive oxide trapped charges. Turn-off time (t off ) was more sensitive to TID irradiation compared to turn-on time (t on ). The switch response changed after irradiation due to parasitic capacitance C GD and threshold voltage degradation. It has been verified by Sentaurus TCAD 2D simulations that the high-speed accumulation of gate oxide traps in the localized region of the trench gate MOS (UMOS) due to the non-uniform distribution of the electric field is the main reason for the special degradation of electrical parameters under drain bias. For TID radiation damage evaluation and radiation hardening of SiC MOSFETs under different biases, both static and dynamic performance should be considered. The experimental results provide valuable insights into the behavior of SiC MOSFETs under radiation and are crucial for designing reliable electronic systems for space and nuclear applications.
This work presents an experimental study of heavy-ion irradiation with different particle linear energy transfer (LET), gate biases, and drain biases. The results reveal that when the irradiation biases are low, the SiC MOSFET does not experience single event effect (SEE) and the electrical properties remain unchanged (the devices are in the safe operating area (SOA)). However, the oxide breakdown voltage of the device is significantly decreased due to the latent damage generated by the irradiation. The experimental results, along with TCAD simulations, suggest that the latent damage induced by the irradiation in the gate oxide is closely related to the peak electric field in the gate oxide at the time of particle incidence. This peak electric field is determined by the potential difference between the two sides of the gate oxide, which is affected by the particle LET, gate biases, and drain biases together. The high potential is determined by the combined effect of the LET and the drain-source voltage. The impact ionization of the particle by the applied electric field causes the accumulation of holes in the JFET oxide, which leads to a decrease in the doping of the N− epitaxial layer and eventually causes a rise in the high potential near the JFET oxide. The low potential is determined by the gate bias, and the negative bias applied to the gate can further increase the potential difference between the two sides of the oxide, causing an increase in the peak electric field in the gate oxide and aggravating the gate oxide damage.