Pham Thi Thanh Ha

Prof. Pham Thi Thanh Ha

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MDMinh Cam Thi Dao
Minh Cam Thi Dao
LTLe Anh Thi
Le Anh Thi
NHNguyen Thi Thanh Huyen
Nguyen Thi Thanh Huyen
LVLe Van Vu
Le Van Vu
NANguyen Thi Kieu Anh
Nguyen Thi Kieu Anh
PHPham Thi Thanh Ha
Pham Thi Thanh Ha

20 June 2005 in Journal of Chromatography A
Verified
Journal Article
Closed access
Jie ZhangJie Zhang
Jie Zhang
PHPham Thi Thanh Ha
Pham Thi Thanh Ha
YLYijia Lou
Yijia Lou
JHJos Hoogmartens
Jos Hoogmartens
ASAnn Van Schepdael
Ann Van Schepdael

18 July 2023 in Molecules
Verified
Journal Article
Open access
PDF file
MDMinh Cam Thi Dao
Minh Cam Thi Dao
LTLe Thi Bao Tram
Le Thi Bao Tram
NPNguyen Hai Phong
Nguyen Hai Phong
HHHoang Thi Lan Huong
Hoang Thi Lan Huong
LVLe Van Vu
Le Van Vu
PHPham Thi Thanh Ha
Pham Thi Thanh Ha
In thin-layer chromatography coupled with surface-enhanced Raman spectroscopy (TLC-SERS), the coffee ring effect (CRE) describes the formation of a ring-shape spot (blank in the middle and darker on the edge) caused by the aggregation of silver nanoparticles (Ag NPs), alone (single CRE) or with the analytes (double CRE). In this work, the SCRE and DCRE were investigated in two anti-diabetic drugs, hydrophobic glibenclamide (GLB) and more hydrophilic metformin (MET). The SCRE occurred in GLB analysis, as opposed to the DCRE that occurred in MET. It was proven that for optimization of the TLC-SERS analytical procedure, it is necessary to distinguish the CRE patterns of analytes. Additionally, MET and GLB were analyzed with the developed TLC-SERS method and confirmed by another validated method using high-performance liquid chromatography. Four herbal products collected on the market were found to be adulterated with GLB or/and MET; among those, one product was adulterated with both MET and GLB, and two products were adulterated with GLB at a higher concentration than the usual GLB prescription dose. The TLC-SERS method provided a useful tool for the simultaneous detection of adulterated anti-diabetic herbal products, and the comparison of the SCRE and DCRE provided more evidence to predict CRE patterns in TLC-SERS.

8 August 2024 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
MDMinh Cam Thi Dao
Minh Cam Thi Dao
NNNguyen Thi Quynh Nhu
Nguyen Thi Quynh Nhu
TLThi Anh Le
Thi Anh Le
LVLe Van Vu
Le Van Vu
DLDang Thi Ngoc Lan
Dang Thi Ngoc Lan
PHPham Thi Thanh Ha
Pham Thi Thanh Ha

1 September 2021 in Journal of Pharmaceutical and Biomedical Analysis
Verified
Journal Article
Closed access
VBVu Ngan Binh
Vu Ngan Binh
VHVu Thi Phuong Hue
Vu Thi Phuong Hue
PHPham Thi Thanh Ha
Pham Thi Thanh Ha

9 October 2024 in Microorganisms
Verified
Journal Article
Open access
PDF file
TNTAM NGUYEN
TAM NGUYEN
ISIsabel Spriet
Isabel Spriet
CQCharlotte Quintens
Charlotte Quintens
LELotte Vander Elst
Lotte Vander Elst
PHPham Thi Thanh Ha
Pham Thi Thanh Ha
EAErwin Adams
Erwin Adams
Although the addition of buffers provides improved stability to flucloxacillin (FLU) solutions, unbuffered solutions are often preferred in clinical practice. The first purpose of this study was to investigate whether a 50 mg/mL solution of FLU in normal saline is stable for 24 h at 33 °C so that it can be applied for outpatient parenteral antimicrobial therapy (OPAT) using portable elastomeric infusion pumps (PEIPs). When the PEIPs were stored in an oven at 33 °C and deflated over 24 h, the volume of the collected solution, pH, and FLU concentration were checked every 4 h. Obtaining better results than expected based on the literature data, other storage conditions, such as refrigeration, room temperature (RT), 37 °C, refrigeration followed by 24 h at 33 °C and 37 °C, and different batches/brands, were also tested. This study confirmed the pronounced effect of temperature on the stability of FLU and also showed the relationship between the stability of FLU and the initial pH of the solution. FLU was quite stable at refrigeration and RT conditions, with more than 99% and 95% remaining. After 24 h at 33 °C, more than 92% of FLU was still present in the solution, while this number decreased to less than 85% when the storage temperature reached 37 °C. The remaining percentage was found to be even lower when the solution was stored at 2–8 °C for 6 days, followed by 24 h storage at 33 °C or 37 °C, with losses of 17% and 30%, respectively. The stability of FLU became worse when the initial pH of the solution was lower than 5.9 since the concentration of FLU dropped to less than 90% after 24 h at 33 °C, and a precipitate started to form when the initial pH of the solution was around 5.3. Therefore, FLU in PEIPs could be employed for 24 h if the temperature was ideally not more than 33 °C, while the pH should be not less than 5.9 upon reconstituting the FLU solution.