Thomas Wall

Mr. Thomas Wall


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 August 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
TWThomas Wall
Thomas Wall
JMJohnny McMurray
Johnny McMurray
GMGopikrishnan Meena
Gopikrishnan Meena
VGVahid Ganjalizadeh
Vahid Ganjalizadeh
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins
Optofluidic, lab-on-a-chip fluorescence sensors were fabricated using buried anti-resonant reflecting optical waveguides (bARROWs). The bARROWs are impervious to the negative water absorption effects that typically occur in waveguides made using hygroscopic, plasma-enhanced chemical vapor deposition (PECVD) oxides. These sensors were used to detect fluorescent microbeads and had an average signal-to-noise ratio (SNR) that was 81.3% higher than that of single-oxide ARROW fluorescence sensors. While the single-oxide ARROW sensors were annealed at 300 °C to drive moisture out of the waveguides, the bARROW sensors required no annealing process to obtain a high SNR.

1 April 2016 in Optical Engineering
Verified
Journal Article
Closed access
PDF file
TWThomas Wall
Thomas Wall
RCRoger P. Chu
Roger P. Chu
JPJoshua W. Parks
Joshua W. Parks
DODamla Ozcelik
Damla Ozcelik
HSHolger Schmidt
Holger Schmidt
AHAaron R. Hawkins
Aaron R. Hawkins
Ridge and buried channel waveguides (BCWs) made using plasma-enhanced chemical vapor deposition SiO2 were fabricated and tested after being subjected to long 85°C water baths. The water bath was used to investigate the effects of any water absorption in the ridge and BCWs. Optical mode spreading and power throughput were measured over a period of three weeks. The ridge waveguides quickly absorbed water within the critical guiding portion of the waveguide. This caused a nonuniformity in the refractive index profile, leading to poor modal confinement after only seven days. The BCWs possessed a low index top cladding layer of SiO2, which caused an increase in the longevity of the waveguides, and after 21 days, the BCW samples still maintained ∼20% throughput, much higher than the ridge waveguides, which had a throughput under 5%.

30 December 2014 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
TWThomas Wall
Thomas Wall
JPJoshua Parks
Joshua Parks
KLKaelyn D. Leake
Kaelyn D. Leake
Holger SchmidtHolger Schmidt
Holger Schmidt
AHAaron Hawkins
Aaron Hawkins