Carlton M. Caves

Prof. Carlton M. Caves


Research Focus & Metrics

Academic Career Length

51Years (1976-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 1994 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
SBSamuel L. Braunstein
Samuel L. Braunstein
CCCarlton M. Caves
Carlton M. Caves
By finding measurements that optimally resolve neighboring quantum states, we use statistical distinguishability to define a natural Riemannian metric on the space of quantum-mechanical density operators and to formulate uncertainty principles that are more general and more stringent than standard uncertainty principles.

15 April 1981 in Physical Review D
Verified
Journal Article
Closed access
PDF file
CCCarlton M. Caves
Carlton M. Caves
The interferometers now being developed to detect gravitational waves work by measuring the relative positions of widely separated masses. Two fundamental sources of quantum-mechanical noise determine the sensitivity of such an interferometer: (i) fluctuations in number of output photons (photon-counting error) and (ii) fluctuations in radiation pressure on the masses (radiation-pressure error). Because of the low power of available continuous-wave lasers, the sensitivity of currently planned interferometers will be limited by photon-counting error. This paper presents an analysis of the two types of quantum-mechanical noise, and it proposes a new technique—the "squeezed-state" technique—that allows one to decrease the photon-counting error while increasing the radiation-pressure error, or vice versa. The key requirement of the squeezed-state technique is that the state of the light entering the interferometer's normally unused input port must be not the vacuum, as in a standard interferometer, but rather a "squeezed state"—a state whose uncertainties in the two quadrature phases are unequal. Squeezed states can be generated by a variety of nonlinear optical processes, including degenerate parametric amplification.

15 October 1982 in Physical Review D
Verified
Journal Article
Closed access
PDF file
CCCarlton M. Caves
Carlton M. Caves
How much noise does quantum mechanics require a linear amplifier to add to a signal it processes? An analysis of narrow-band amplifiers (single-mode input and output) yields a fundamental theorem for phase-insensitive linear amplifiers; it requires such an amplifier, in the limit of high gain, to add noise which, referred to the input, is at least as large as the half-quantum of zero-point fluctuations. For phase-sensitive linear amplifiers, which can respond differently to the two quadrature phases ("cosωt" and "sinωt"), the single-mode analysis yields an amplifier uncertainty principle—a lower limit on the product of the noises added to the two phases. A multimode treatment of linear amplifiers generalizes the single-mode analysis to amplifiers with nonzero bandwidth. The results for phase-insensitive amplifiers remain the same, but for phase-sensitive amplifiers there emerge bandwidth-dependent corrections to the single-mode results. Specifically, there is a bandwidth-dependent lower limit on the noise carried by one quadrature phase of a signal and a corresponding lower limit on the noise a high-gain linear amplifier must add to one quadrature phase. Particular attention is focused on developing a multimode description of signals with unequal noise in the two quadrature phases.

1 June 2004 in Journal of Mathematical Physics
Verified
Journal Article
Closed access
JRJoseph M. Renes
Joseph M. Renes
RBRobin Blume-Kohout
Robin Blume-Kohout
ASA. J. Scott
A. J. Scott
CCCarlton M. Caves
Carlton M. Caves
We consider the existence in arbitrary finite dimensions d of a positive operator valued measure (POVM) comprised of d2 rank-one operators all of whose operator inner products are equal. Such a set is called a “symmetric, informationally complete” POVM (SIC–POVM) and is equivalent to a set of d2 equiangular lines in Cd. SIC–POVMs are relevant for quantum state tomography, quantum cryptography, and foundational issues in quantum mechanics. We construct SIC–POVMs in dimensions two, three, and four. We further conjecture that a particular kind of group-covariant SIC–POVM exists in arbitrary dimensions, providing numerical results up to dimension 45 to bolster this claim.

5 February 2008 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
ADAnimesh Datta
Animesh Datta
ASAnil Shaji
Anil Shaji
CCCarlton M. Caves
Carlton M. Caves
We use quantum discord to characterize the correlations present in the model called deterministic quantum computation with one quantum bit (DQC1), introduced by Knill and Laflamme [ Phys. Rev. Lett. 81, 5672 (1998)]. The model involves a collection of qubits in the completely mixed state coupled to a single control qubit that has nonzero purity. The initial state, operations, and measurements in the model all point to a natural bipartite split between the control qubit and the mixed ones. Although there is no entanglement between these two parts, we show that the quantum discord across this split is nonzero for typical instances of the DQC1 ciruit. Nonzero values of discord indicate the presence of nonclassical correlations. We propose quantum discord as figure of merit for characterizing the resources present in this computational model.

1 April 1980 in Reviews of Modern Physics
Verified
Journal Article
Closed access
PDF file
CCCarlton M. Caves
Carlton M. Caves
KTKip S. Thorne
Kip S. Thorne
RDRonald W. P. Drever
Ronald W. P. Drever
VSVernon D. Sandberg
Vernon D. Sandberg
MZMark Zimmermann
Mark Zimmermann
The monitoring of a quantum-mechanical harmonic oscillator on which a classical force acts is important in a variety of high-precision experiments, such as the attempt to detect gravitational radiation. This paper reviews the standard techniques for monitoring the oscillator, and introduces a new technique which, in principle, can determine the details of the force with arbitrary accuracy, despite the quantum properties of the oscillator. The standard method for monitoring the oscillator is the "amplitude-and-phase" method (position or momentum transducer with output fed through a narrow-band amplifier). The accuracy obtainable by this method is limited by the uncertainty principle ("standard quantum limit"). To do better requires a measurement of the type which Braginsky has called "quantum nondemolition." A well known quantum nondemolition technique is "quantum counting," which can detect an arbitrarily weak classical force, but which cannot provide good accuracy in determining its precise time dependence. This paper considers extensively a new type of quantum nondemolition measurement—a "back-action-evading" measurement of the real part X1 (or the imaginary part X2) of the oscillator's complex amplitude. In principle X1 can be measured "arbitrarily quickly and arbitrarily accurately," and a sequence of such measurements can lead to an arbitrarily accurate monitoring of the classical force. The authors describe explicit Gedanken experiments which demonstrate that X1 can be measured arbitrarily quickly and arbitrarily accurately. In these experiments the measuring apparatus must be coupled to both the position (position transducer) and the momentum (momentum transducer) of the oscillator, and both couplings must be modulated sinusoidally. For a given measurement time the strength of the coupling determines the accuracy of the measurement; for arbitrarily strong coupling the measurement can be arbitrarily accurate. The "momentum transducer" is constructed by combining a "velocity transducer" with a "negative capacitor" or "negative spring." The modulated couplings are provided by an external, classical generator, which can be realized as a harmonic oscillator excited in an arbitrarily energetic, coherent state. One can avoid the use of two transducers by making "stroboscopic measurements" of X1, in which one measures position (or momentum) at half-cycle intervals. Alternatively, one can make "continuous single-transducer" measurements of X1 by modulating appropriately the output of a single transducer (position or momentum), and then filtering the output to pick out the information about X1 and reject information about X2. Continuous single-transducer measurements are useful in the case of weak coupling. In this case long measurement times are required to achieve good accuracy, and continuous single-transducer measurements are almost as good as perfectly coupled two-transducer measurements. Finally, the authors develop a theory of quantum nondemolition measurement for arbitrary systems. This paper (Paper I) concentrates on issues of principle; a sequel (Paper II) will consider issues of practice.