Optical 3D surface scanning is used increasingly to assess spinal deformity of patients with scoliosis. However, approaches based on optical 3D scanning often underestimate the spinal deformity. To improve the accuracy of such estimates, deeper understanding is required of scoliosis and its effect on the back shape. We present the PCdare research software which registers 3D surface scans with the corresponding biplanar radiographs semi-automatically and facilitates investigations into the relationship between surface and internal modalities. PCdare revealed very strong correlations between the spinous process line and internal spinal alignment, and a median Cobb angle difference of less than 1° from the clinical gold standard. These results increase confidence in the use of 3D scanning with a “back-shape-to-spine” approach and confirm the applicability of PCdare to investigate the relationship between internal alignment and back shape in research.
Adolescent idiopathic scoliosis (AIS) is a prevalent musculoskeletal disorder that causes abnormal spinal deformities. The early screening of children and adolescents is crucial to identify and prevent the further progression of AIS. In clinical examinations, scoliometers are often used to noninvasively estimate the primary Cobb angle, and optical 3D scanning systems have also emerged as alternative noninvasive approaches for this purpose. The recent advances in low-cost 3D scanners have led to their use in several studies to estimate the primary Cobb angle or even internal spinal alignment. However, none of these studies demonstrate whether such a low-cost scanner satisfies the minimal requirements for capturing the relevant deformities of the human back. To practically quantify the minimal required spatial resolution and camera resolution to capture the geometry and shape of the deformities of the human back, we used multiple 3D scanning methodologies and systems. The results from an evaluation of 30 captures of AIS patients and 76 captures of healthy subjects showed that the minimal required spatial resolution is between 2 mm and 5 mm, depending on the chosen error tolerance. Therefore, a minimal camera resolution of 640 × 480 pixels is recommended for use in future studies.
Optical 3D scanning applications are increasingly used in various medical fields. Setups involving multiple adjustable systems require repeated extrinsic calibration between patients. Existing calibration solutions are either not applicable to the medical field or require a time-consuming process with multiple captures and target poses. Here, we present an application with a 3D checkerboard (3Dcb) for extrinsic calibration with a single capture. The 3Dcb application can register captures with a reference to validate measurement quality. Furthermore, it can register captures from camera pairs for point-cloud stitching of static and dynamic scenes. Registering static captures from TIDA-00254 to its reference from a Photoneo MotionCam-3D resulted in an error (root mean square error ± standard deviation) of 0.02 mm ± 2.9 mm. Registering a pair of Photoneo MotionCam-3D cameras for dynamic captures resulted in an error of 2.2 mm ± 1.4 mm. These results show that our 3Dcb implementation provides registration for static and dynamic captures that is sufficiently accurate for clinical use. The implementation is also robust and can be used with cameras with comparatively low accuracy. In addition, we provide an extended overview of extrinsic calibration approaches and the application’s code for completeness and service to fellow researchers.
Medical applications in which patient movements are tracked with 3D surface imaging systems are becoming increasingly popular. The 3D imaging systems used for such applications must be able to cope with controlled and uncontrolled motions of the human body. The key factors for producing a high-quality 3D representation of the moving human body are the spatial resolution, accuracy, and precision of the 3D imaging system. To our knowledge, no international standard yet exists to assess these parameters. In this paper, we propose a phantom model, a method, and parameters for the assessment of spatial resolution, accuracy, and precision to evaluate systems for the 3D imaging of moving objects. The proposed phantom model is an extension of the standard 1951 USAF resolution test chart to 3D and consists of two parallel staircases with varying step heights. The phantom model is actuated with an industrial robot. The application of our method to the Photoneo MotionCam-3D showed that their multishot structured-light mode has a higher accuracy for static and slowly moving objects (accuracy of 0.1 mm) than their single-shot structured-light mode (accuracy of 0.5 mm). However, the single-shot mode can capture fast-moving objects without much loss of accuracy and precision. This provides practical quantifications for the Photoneo MotionCam-3D. Furthermore, this confirms that the proposed phantom model, method, and parameters can be used as part of a standard to assess the spatial resolution, accuracy, and precision of systems for the 3D imaging of moving objects.
Optical 3D surface scanning is used increasingly to assess spinal deformity in patients with adolescent idiopathic scoliosis (AIS), largely because it avoids additional radiation burden. However, such approaches generally underestimate the extent of the abnormality. Improving the accuracy of such estimates requires a deeper understanding of AIS and its effect on back shape. We present a unique platform with publicly available code that contains noninvasive and nonionizing approaches to estimating the Cobb angle of the primary curve, called primary Cobb angle (pCA) and internal spinal alignment (ISL) in patients with AIS. Our approaches use asymmetries of the back shape during upright standing, the Adam’s forward bending test, bending forward, and lateral bending. The results have revealed strong (0.75 [0.53, 0.87]) to excellent (0.91 [0.81, 0.96]) correlations [95% confidence interval] and a median pairwise absolute error (IQR) of 3.4° (6.8°) between the estimated pCAs and clinical gold-standard assessments in 30 patients. The correlations (IQR) between estimated shape of ISLs and their references were very strong (0.87 (0.24)) to excellent (0.94 (0.03)), and the median root mean square error (IQR) between estimated and reference ISL was 6.9 mm (3.3 mm). These results indicate confidence both in the use of 3D scanning using a “back-shape-to-spine” approach and in the establishment of optical 3D surface scanning approaches for scoliosis screening and monitoring in clinical practice.