Chunchao Huang

Dr. Chunchao Huang

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2024 in Energy
Verified
Journal Article
Closed access
CHChunchao Huang
Chunchao Huang
ZLZhengqi Li
Zhengqi Li
YLYue Lu
Yue Lu
ZCZhichao Chen
Zhichao Chen
HLHuacai Liu
Huacai Liu
WWWu Wei
Wu Wei

8 January 2024 in Applied Thermal Engineering
Verified
Journal Article
Closed access
CHChunchao Huang
Chunchao Huang
ZLZhengqi Li
Zhengqi Li
YWYufei Wang
Yufei Wang
FFFan Fang
Fan Fang
HLHuacai Liu
Huacai Liu
YLYujie Liu
Yujie Liu

16 January 2025 in Energy
Verified
Journal Article
Closed access
CHChunchao Huang
Chunchao Huang
ZLZhengqi Li
Zhengqi Li
YLYue Lu
Yue Lu
HLHuacai Liu
Huacai Liu
FFFan Fang
Fan Fang
ZCZhichao Chen
Zhichao Chen

28 February 2022 in Journal of Thermal Analysis and Calorimetry
Verified
Journal Article
Closed access
PDF file
CHChunchao Huang
Chunchao Huang
CYChunmei Yu
Chunmei Yu
Guangwei WangGuangwei Wang
Guangwei Wang
JZJianliang Zhang
Jianliang Zhang
XNXiaojun Ning
Xiaojun Ning
Chuan WangChuan Wang
Chuan Wang

1 March 2025 in Energy
Verified
Journal Article
Closed access
CHChunchao Huang
Chunchao Huang
ZLZhengqi Li
Zhengqi Li
YLYue Lu
Yue Lu
HLHuacai Liu
Huacai Liu
ZCZhichao Chen
Zhichao Chen

26 June 2023 in Processes
Verified
Journal Article
Open access
PDF file
CHChunchao Huang
Chunchao Huang
Zhengqi LiZhengqi Li
Zhengqi Li
YWYufei Wang
Yufei Wang
YLYue Lu
Yue Lu
HLHuacai Liu
Huacai Liu
ZCZhichao Chen
Zhichao Chen
On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.