Gregor Scholz

Mr. Gregor Scholz


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
GSGregor Scholz
Gregor Scholz
SMShinta Mariana
Shinta Mariana
ADAgus Budi Dharmawan
Agus Budi Dharmawan
ISIqbal Syamsu
Iqbal Syamsu
PHPhilipp Hörmann
Philipp Hörmann
AWAndreas Waag
Andreas Waag
Continuous cell culture monitoring as a way of investigating growth, proliferation, and kinetics of biological experiments is in high demand. However, commercially available solutions are typically expensive and large in size. Digital inline-holographic microscopes (DIHM) can provide a cost-effective alternative to conventional microscopes, bridging the gap towards live-cell culture imaging. In this work, a DIHM is built from inexpensive components and applied to different cell cultures. The images are reconstructed by computational methods and the data are analyzed with particle detection and tracking methods. Counting of cells as well as movement tracking of living cells is demonstrated, showing the feasibility of using a field-portable DIHM for basic cell culture investigation and bringing about the potential to deeply understand cell motility.

17 February 2022 in Metrology
Verified
Journal Article
Open access
PDF file
GSGregor Scholz
Gregor Scholz
IFInes Fortmeier
Ines Fortmeier
MMManuel Marschall
Manuel Marschall
MSManuel Stavridis
Manuel Stavridis
MSMichael Schulz
Michael Schulz
ECElster Clemens
Elster Clemens
The tilted-wave interferometer (TWI) is a recent and promising technique for optically measuring aspheres and freeform surfaces and combines an elaborate experimental setup with sophisticated data analysis algorithms. There are, however, many parameters that influence its performance, and greater knowledge about the behavior of the TWI is needed before it can be established as a measurement standard. Virtual experiments are an appropriate tool for this purpose, and in this paper we present a digital twin of the TWI that was carefully designed for such experiments. The expensive numerical calculations involved combined with the existence of multiple influencing parameters limit the number of virtual experiments that are feasible, which poses a challenge to researchers. Experimental design is a statistical technique that allows virtual experiments to be planned such as to maximize information gain. We applied experimental design to virtual TWI experiments with the goal of identifying the main sources of uncertainty. The results from this work are presented here.

22 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
GSGregor Scholz
Gregor Scholz
QXQifeng Xu
Qifeng Xu
TSTorben Schulze
Torben Schulze
HBHeidi Boht
Heidi Boht
KMKai Mattern
Kai Mattern
AWAndreas Waag
Andreas Waag
A portable lensless imaging device combining light-emitting diodes (LEDs) and a CMOS image sensor was developed and its suitability for non-invasive live-cell in vitro monitoring of pancreatic islets was demonstrated. A microfluidic lab-on-a-chip platform containing micro wells with various depths was also fabricated and integrated into the optical sensor system, which allows for immobilization of the single islets and continuous recording of their behavior. This promising technique may provide further insight into the structure and function of pancreatic islets and their deficiencies in type 2 diabetes.

21 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
SMShinta Mariana
Shinta Mariana
GSGregor Scholz
Gregor Scholz
FYFeng Yu
Feng Yu
ADAgus Budi Dharmawan
Agus Budi Dharmawan
ISIqbal Syamsu
Iqbal Syamsu
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
Pinhole‐shaped light‐emitting diode (LED) arrays with dimension ranging from 100 μm down to 5 μm have been developed as point illumination sources. The proposed microLED arrays, which are based on gallium nitride (GaN) technology and emitting in the blue spectral region (λ = 465 nm), are integrated into a compact lensless holographic microscope for a non‐invasive, label‐free cell sensing and imaging. From the experimental results using single pinhole LEDs having a diameter of 90 μm, the reconstructed images display better resolution and enhanced image quality compared to those captured using a commercial surface‐mount device (SMD)‐based LED.

15 May 2024 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
GSGregor Scholz
Gregor Scholz
LYLing Yang
Ling Yang
MSMarkus Schake
Markus Schake
IFInes Fortmeier
Ines Fortmeier
Accurate and flexible form measurements for aspherical and freeform surfaces are in high demand, and non-null-test interferometric methods such as tilted-wave interferometry have gained attention as a promising response to this need. Interferometric methods, however, display ambiguities between the measurement of certain form errors and the misalignment of the measured specimen. Therefore, improved knowledge of the absolute measurement position of the specimen in relation to the interferometer setup may improve the form measurement result. In this work, we propose a concept that uses a white light interferometer to measure the absolute distance between a transparent specimen's surface and the interferometer's objective and present preparatory data to qualify the white light interferometer for the improvement of tilted-wave interferometer measurements.

5 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
GSGregor Scholz
Gregor Scholz
SMShinta Mariana
Shinta Mariana
ISIqbal Syamsu
Iqbal Syamsu
ADAgus Budi Dharmawan
Agus Budi Dharmawan
TSTorben Schulze
Torben Schulze
HWHutomo Suryo Wasisto
Hutomo Suryo Wasisto
A compact lensless microscope comprising a custom-made LED engine and a CMOS imaging sensor has been developed for live-cell culture imaging inside a cell incubator environment. The imaging technique is based on digital inline-holographic microscopy, while the image reconstruction is carried out by angular spectrum approach with a custom written software. The system was tested with various biological samples including immortalized mouse astrocyte cells inside a petri dish. Besides the imaging possibility, the capability of automated cell counting and tracking could be demonstrated. By using image sensors capable of video frame rate, time series of cell movement can be captured.