This work presents a solution for controlling an Asynchronous Motor Drive (AMD) using a Gamma Z Source Inverter (GZSI) in combination with a high-gain Quadratic Boost Converter (QBC). The higher voltage gain of QBC and GZSI reduces the voltage rating of PV. Reduced output voltage ripple of QBC improves the performance of the AMD system. The proposed PV-QBC-GZSI-AMD system aims to regulate the motor’s speed for applications requiring a constant speed. The approach involves implementing a closed-loop control system and evaluating different controllers: Current-mode-Fractional Order Proportional Integral (CM-FOPI), Current-mode-Proportional Resonant (CM-PR), and Current Mode-Hysteresis Controller (CM-HC). Also, FOPI improves the robustness and the hysteretic controller reduces the current-ripple implemented in this model. Hence, the system’s performance is assessed using MATLAB/Simulink, showcasing enhanced dynamic performance in speed and torque characteristics within the time domain when employing CM-FOPI, CM-PR, and CM-HC control strategies for PV-QBC-GZSI-AMD. Simulation outcomes are compared against actual motor speed and torque data, highlighting the superior performance of the closed-loop-CM-HC control in PV-QBC-GZSI-AMD over closed-loop-CM-FOPI and CM-PR methods. Closed-loop-CM-HC control also provides over current protection. The study also includes hardware results from the PV-QBC-GZSI-AMD system, validating the simulation findings. Furthermore, the performance of the proposed converter topology is compared with notable existing works, considering essential factors such as the number of stages, loops, control method, load type, performance parameters, and associated limitations.
1 December 2023 in International Journal of Power Electronics and Drive Systems (IJPEDS)
A closed loop current mode-fractional-order-PID (CM-FOPID) controlled and PV based quadratic-boost-converter (QBC) fed gamma Z-Source Inverter with Induction motor system (PV-QBC-GZSI-IMS) for pump operation is proposed here. This work recommends a combination of QBC with gamma Z-source-inverter between the DC link source and asynchronous motor system. This will reduce the voltage rating of PV panel and its initial cost. GZSI reduces the current spikes in stator current. The objective of this research work is to regulate the speed of PV-QBC-GZSI-IMS. This effort deals with the closed loop response of PV-QBC-GZSI-IMS accompanied by current-mode-proportional integral (CM-PI) and CM-FOPID controllers. The performance investigations are analyzed with the control of QBC fed Gamma Z-source inverter with motor load using CM-PI and CM-FOPID controllers and the detailed comparison has been presented. MATLAB/Simulink outputs obtained with their respective speed and torque characteristics in time domain have been depicted. The closed loop CM-FOPID control of PV-QBC-GZSI-IMS is superior to the closed loop CM-PI control of PV-QBC-GZSI-IMS. The proposed QBC-converter reduces the voltage rating of PV panel and GZSI reduces current spikes in motor. The novelty of the article is to enhance the dynamic response of PV-QBC-GZSI-IMS using FOPID. The steady state error in torque is reduced to 0.52 N-m using FOPID.