Lena Sophie Kiefer

Dr. Lena Sophie Kiefer

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
EOEduardo Enrique Calderón Ochoa
Eduardo Enrique Calderón Ochoa
FSFabian P. Schmidt
Fabian P. Schmidt
WLWenhong Lan
Wenhong Lan
SVSalvador Castaneda Vega
Salvador Castaneda Vega
ABAndreas Stefan Brendlin
Andreas Stefan Brendlin
LKLena Sophie Kiefer
Lena Sophie Kiefer
PET/CT scanners with a long axial field-of-view (LAFOV) provide increased sensitivity, enabling the adjustment of imaging parameters by reducing the injected activity or shortening the acquisition time. This study aimed to evaluate the limitations of reduced [18F]FDG activity doses on image quality, lesion detectability, and the quantification of lesion uptake in the Biograph Vision Quadra, as well as to assess the benefits of the recently introduced ultra-high sensitivity mode in a clinical setting. A number of 26 patients who underwent [18F]FDG-PET/CT (3.0 MBq/kg, 5 min scan time) were included in this analysis. The PET raw data was rebinned for shorter frame durations to simulate 5 min scans with lower activities in the high sensitivity (HS) and ultra-high sensitivity (UHS) modes. Image quality, noise, and lesion detectability (n = 82) were assessed using a 5-point Likert scale. The coefficient of variation (CoV), signal-to-noise ratio (SNR), tumor-to-background ratio (TBR), and standardized uptake values (SUV) including SUVmean, SUVmax, and SUVpeak were evaluated. Subjective image ratings were generally superior in UHS compared to the HS mode. At 0.5 MBq/kg, lesion detectability decreased to 95% (HS) and to 98% (UHS). SNR was comparable at 1.0 MBq/kg in HS (5.7 ± 0.6) and 0.5 MBq/kg in UHS (5.5 ± 0.5). With lower doses, there were negligible reductions in SUVmean and SUVpeak, whereas SUVmax increased steadily. Reducing the [18F]FDG activity to 1.0 MBq/kg (HS/UHS) in a LAFOV PET/CT provides diagnostic image quality without statistically significant changes in the uptake parameters. The UHS mode improves image quality, noise, and lesion detectability compared to the HS mode.

29 April 2021 in Diabetes, Obesity and Metabolism
Verified
Journal Article
Open access
PDF file
LKLena Sophie Kiefer
Lena Sophie Kiefer
JFJana Fabian
Jana Fabian
SRSusanne Rospleszcz
Susanne Rospleszcz
RLRoberto Lorbeer
Roberto Lorbeer
JMJürgen Machann
Jürgen Machann
FBFabian Bamberg
Fabian Bamberg
Aim: To evaluate the distribution of intramyocellular lipids (IMCLs) and extramyocellular lipids (EMCLs) as well as total fat content in abdominal skeletal muscle by magnetic resonance imaging (MRI) using a dedicated segmentation algorithm in subjects with type 2 diabetes (T2D), prediabetes and normoglycaemic controls. Materials and Methods: Subjects from a population‐based cohort were classified with T2D, prediabetes or as normoglycaemic controls. Total myosteatosis, IMCLs and EMCLs were quantified by multiecho Dixon MRI as proton‐density fat‐fraction (in %) in abdominal skeletal muscle. Results: Among 337 included subjects (median age 56.0 [IQR: 49.0‐64.0] years, 56.4% males, median body mass index [BMI]: 27.2 kg/m 2 ), 129 (38.3%) were classified with an impaired glucose metabolism (T2D: 49 [14.5%]; prediabetes: 80 [23.7%]). IMCLs were significantly higher than EMCLs in subjects without obesity (5.7% [IQR: 4.8%‐7.0%] vs. 4.1% [IQR: 2.7%‐5.8%], P < .001), whereas the amounts of IMCLs and EMCLs were shown to be equal and significantly higher in subjects with obesity (both 6.7%, P < .001). Subjects with prediabetes and T2D had significantly higher amounts of IMCLs and EMCLs compared with normoglycaemic controls ( P < .001). In univariable analysis, prediabetes and T2D were significantly associated with both IMCLs (prediabetes: β: 0.76, 95% CI: 0.28‐1.24, P = .002; T2D: β: 1.56, 95% CI: 0.66‐2.47, P < .001) and EMCLs (prediabetes: β: 1.54, 95% CI: 0.56‐2.51, P = .002; T2D: β: 2.15, 95% CI: 1.33‐2.96, P < .001). After adjustment for age and gender, the association of IMCLs with prediabetes attenuated ( P = 0.06), whereas for T2D, both IMCLs and EMCLs remained significantly and positively associated ( P < .02). Conclusion: There are significant differences in the amount and distribution ratio of IMCLs and EMCLs between subjects with T2D, prediabetes and normoglycaemic controls. Therefore, these patterns of intramuscular fat distribution by MRI might serve as imaging biomarkers in both normal and impaired glucose metabolism.

25 January 2022 in Journal of Cachexia, Sarcopenia and Muscle
Verified
Journal Article
Open access
PDF file
LKLena Sophie Kiefer
Lena Sophie Kiefer
JFJana Fabian
Jana Fabian
SRSusanne Rospleszcz
Susanne Rospleszcz
RLRoberto Lorbeer
Roberto Lorbeer
JMJürgen Machann
Jürgen Machann
FBFabian Bamberg
Fabian Bamberg
Background: Skeletal muscle mass is subjected to constant changes and is considered a good predictor for outcome in various diseases. Bioelectrical‐impedance analysis (BIA) and magnetic resonance imaging (MRI) are approved methodologies for its assessment. However, muscle mass estimations by BIA may be influenced by excess intramuscular lipids and adipose tissue in obesity. The objective of this study was to evaluate the feasibility of quantitative assessment of skeletal muscle mass by MRI as compared with BIA.Methods: Subjects from a population‐based cohort underwent BIA (50 kHz, 0.8 mA) and whole‐body MRI including chemical‐shift encoded MRI (six echo times). Abdominal muscle mass by MRI was quantified as total and fat‐free cross‐sectional area by a standardized manual segmentation‐algorithm and normalized to subjects' body height2 (abdominal muscle mass indices: AMMIMRI).Results: Among 335 included subjects (56.3 ± 9.1 years, 56.1% male), 95 (28.4%) were obese (BMI ≥ 30 kg/m2). MRI‐based and BIA‐based measures of muscle mass were strongly correlated, particularly in non‐obese subjects [r < 0.74 in non‐obese (P < 0.001) vs. r < 0.56 in obese (P < 0.001)]. Median AMMITotal(MRI) was significantly higher in obese as compared with non‐obese subjects (3246.7 ± 606.1 mm2/m2 vs. 2839.0 ± 535.8 mm2/m2, P < 0.001, respectively), whereas the ratio AMMIFat‐free/AMMITotal (by MRI) was significantly higher in non‐obese individuals (59.3 ± 10.1% vs. 53.5 ± 10.6%, P < 0.001, respectively). No significant difference was found regarding AMMIFat‐free(MRI) (P = 0.424). In analyses adjusted for age and sex, impaired glucose tolerance and measures of obesity were significantly and positively associated with AMMITotal(MRI) and significantly and inversely with the ratio AMMIFat‐free(MRI)/AMMITotal(MRI) (P < 0.001).Conclusions: MRI‐based assessment of muscle mass is feasible in population‐based imaging and strongly correlated with BIA. However, the observed weaker correlation in obese subjects may explain the known limitation of BIA in obesity and promote MRI‐based assessments. Thus, skeletal muscle mass parameters by MRI may serve as practical imaging biomarkers independent of subjects' body weight.

23 January 2024 in Clinical Nuclear Medicine
Verified
Journal Article
Open access
NTNils Florian Trautwein
Nils Florian Trautwein
CHClemens Hinterleitner
Clemens Hinterleitner
LKLena Sophie Kiefer
Lena Sophie Kiefer
SSStephan Singer
Stephan Singer
SMSven Mattern
Sven Mattern
MHMartina Hinterleitner
Martina Hinterleitner
Aim/Introduction: Peptide receptor radionuclide therapy (PRRT) represents a cornerstone of treatment regimens for patients with low proliferative neuroendocrine tumors (NETs). However, in patients experiencing somatostatin receptor–positive NET with higher proliferation rates, a value and potential therapeutic benefit of PRRT as part of multimodal treatment approaches and potentially with addition of radiosensitizing agents has not yet been established. Patients and Methods: In this study, 20 patients with histologically confirmed gastroenteropancreatic (GEP) NET with proliferation rates (Ki67) between 15% and 55% were treated either with PRRT only (n = 10) or with a combination therapy (n = 10) comprising PRRT and capecitabine/temozolomide (CAP/TEM) for at least 2 consecutive cycles. Results: Disease control rate in patients treated with PRRT alone was 60% (40% stable disease and 20% partial response). Strikingly, in patients treated with PRRT in combination with radiosensitization (CAP/TEM), the disease control rate was 90% (20% stable disease and 70% partial response). The median progression-free survival in the PRRT only group was 12 months, whereas the median progression-free survival in the PRRT + CAP/TEM group was 26 months and has not been yet reached for all patients in the group during the observation period. The median disease-specific survival for patients with PRRT alone was 51 months, whereas this end point was not yet reached in the PRRT + CAP/TEM group. Moreover, the PRRT + CAP/TEM group showed a significantly higher reduction of SSTR-PET–based metabolic tumor volume and chromogranin A levels compared with the PRRT only group. Importantly, adverse events of all grades did not differ between both groups. Conclusions: PRRT + CAP/TEM represents a highly promising and well-tolerated therapeutic regimen for patients experiencing somatostatin receptor–positive NET with higher (Ki67 ≥ 15%) proliferation rate. Prospective randomized clinical trials are warranted.

21 October 2023 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Open access
FSFabian P. Schmidt
Fabian P. Schmidt
JMJulia G. Mannheim
Julia G. Mannheim
PLPia Marie-Luise Linder
Pia Marie-Luise Linder
PWP. Will
P. Will
LKLena Sophie Kiefer
Lena Sophie Kiefer
IRIvo Rausch
Ivo Rausch
The sensitivity of a PET system highly depends on the axial acceptance angle or maximum ring difference (MRD), which can be particularly high for total-body scanners due to their larger axial field of views (aFOVs). This study aims to evaluate the impact on image quality (IQ) and noise performance when MRD85 (18°), the current standard for clinical use, is increased to MRD322 (52°) for the Biograph Vision Quadra (Siemens Healthineers). Studies with a cylindrical phantom covering the 106 cm aFOV and an IEC phantom filled with 18F, 68Ga and 89Zr were performed for acquisition times from 60 to 1800 s and activity concentrations from 0.4 to 3 kBq/ml to assess uniformity, contrast recovery coefficients (CRCs) and to characterize noise by coefficient of variation (CV). Spatial resolution was compared for both MRDs by sampling a quadrant of the FOV with a point source. Further IQ, CV, liver SUVmean and SUVmax were compared for a cohort of 5 patients scanned with [18F]FDG (3 MBq/kg, 1 h p.i.) from 30 to 300 s. CV was improved by a factor of up to 1.49 and is highest for short acquisition times, peaks at the center field of view and mitigates parabolic in axial direction with no difference to MRD85 beyond the central 80 cm. No substantial differences between the two evaluated MRDs in regards to uniformity, SUVmean or CRC for the different isotopes were observed. A degradation of the average spatial resolution of 0.9 ± 0.2 mm in the central 40 cm FOV was determined with MRD322. Depending on the acquisition time MRD322 resulted in a decrease of SUVmax between 23.8% (30 s) and 9.0% (300 s). Patient and phantom studies revealed that scan time could be lowered by approximately a factor of two with MRD322 while maintaining similar noise performance. The moderate degradation in spatial resolution for MRD322 is worth to exploit the full potential of the Quadra by either shorten scan times or leverage noise performance in particular for low count scenarios such as ultra-late imaging or dynamic studies with high temporal resolution.

24 May 2021 in BJR|Open
Verified
Journal Article
Open access
LKLena Sophie Kiefer
Lena Sophie Kiefer
JSJulia Sekler
Julia Sekler
BGBrigitte Gückel
Brigitte Gückel
MKMareen Sarah Kraus
Mareen Sarah Kraus
CFChristian la Fougère
Christian la Fougère
CPChristina Pfannenberg
Christina Pfannenberg
Objective: To determine the impact of 18F-FDG-PET/CT on clinical management of patients with cholangiocellular carcinoma (CCA). Methods: Patients with CCA undergoing clinically indicated 18F-FDG-PET/CT between 04/2013 and 08/2018 were prospectively included in a local PET/CT registry study. Intended clinical management (“non-treatment” such as watchful-waiting or additional diagnostic tests, and “palliative” or “curative treatment”) was recorded before and after PET/CT. Changes in intended management after PET/CT were analyzed. Results: 27 patients (mean age: 60 years, IQR: 51.5–67.5 years, 56% males) with 43 PET/CT examinations were included. Intended management changed in 35/43 cases (81.4%) following PET/CT. Major changes (i.e., between “non-treatment” and “treatment” strategies or between a “curative” and “palliative” treatment goal) occurred in 27/43 (62.8%) cases. Before PET/CT, additional imaging and/or biopsy were intended in 21/43 (48.8%) and 9/43 (20.9%) cases, respectively. After PET/CT, further imaging was carried out in one case and imaging-targeted biopsy in eight cases. Although the absolute number of biopsies after PET/CT did not decrease, in only one of these eight cases biopsy had already been planned before PET/CT, whereas in the other eight cases, the originally planned biopsies were dispensable after PET/CT. Conclusions: 18F-FDG-PET/CT significantly impacts clinical management of patients with CCA. It guides decisions on treatment strategy (especially curative vs palliative treatment goal) and on additional tests, particularly by helping referring clinicians to avoid unnecessary imaging and by guiding targeted biopsy. Advances in knowledge: Systematic implementation of 18F-FDG-PET/CT may enable a more appropriate and tailored treatment of patients with CCA, especially in cases of suspected recurrence.