Junqi Wang

Dr. Junqi Wang


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2012 in Organic & Biomolecular Chemistry
Verified
Journal Article
Closed access
PDF file
JWJunqi Wang
Junqi Wang
LYLingyun Yang
Lingyun Yang
CHChen Hou
Chen Hou
Haishi CaoHaishi Cao
Haishi Cao
A chemosensor is reported with high sensitivity and selectivity for detection of fluoride anion. The recognition mechanism is attributed to a fluoride-triggered disruption of the hydrogen bond between imidazole and naphthalimide moieties, resulting in a noncoplanar geometry with low fluorescence.

6 March 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
JWJunqi Wang
Junqi Wang
NNNicolas Nuñovero
Nicolas Nuñovero
RNRobert Nidetz
Robert Nidetz
SPSeth J. Peterson
Seth J. Peterson
BBBryan M. Brookover
Bryan M. Brookover
EZEdward Zellers
Edward Zellers

9 April 2018 in Microsystems & Nanoengineering
Verified
Journal Article
Open access
PDF file
JWJunqi Wang
Junqi Wang
JBJonathan Bryant-Genevier
Jonathan Bryant-Genevier
NNNicolas Nuñovero
Nicolas Nuñovero
CZChengyi Zhang
Chengyi Zhang
BKBruce Kraay
Bruce Kraay
EZEdward Zellers
Edward Zellers
This report concerns a benchtop prototype instrument containing a gas chromatographic microanalytical system (μGC) designed for the selective determination of multiple airborne volatile organic compounds (VOCs) at concentrations in the vicinity of recommended occupational exposure limits. The core microsystem consists of a set of discrete Si-microfabricated devices: a dual-cavity, adsorbent-packed micro-preconcentrator-focuser (μPCF) chip that quantitatively captures and thermally desorbs/injects VOCs with vapor pressures between ~0.03 and 13 kPa; tandem micro-column (μcolumn) chips with cross-linked PDMS wall-coated stationary phases capable of temperature-programmed separations; and an integrated array of five μchemiresistors (μCR) coated with different thiolate-monolayer protected gold nanoparticle (MPN) interface films that quantifies and further differentiates among the analytes by virtue of the response patterns generated. Other key components include a pre-trap for low-volatility interferences, a split-flow injection valve, and an onboard He carrier–gas canister. The assembled unit measures 19×30×14 cm, weighs ~3.5 kg, operates on AC power, and is laptop/LabVIEW controlled. Component- and system-level tests of performance demonstrated injection bandwidths <1 s, a μcolumn capacity of ≥8 μg injected mass, linear calibration curves, no humidity effects, excellent medium-term (that is, 1 week) reproducibility, autonomous operation for 8 h, detection limits below Threshold Limit Values (TLV) for 10 mL air samples collected in 1 min, and response patterns that enhanced vapor recognition. The determination of a 17-VOC mixture in the presence of seven interferences was performed in 4 min. Results augur well for adapting the microsystem to an all-MEMS wearable μGC currently under parallel development.

1 January 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ZLZhijin Lin
Zhijin Lin
NNNicolás Nuñovero
Nicolás Nuñovero
JWJunqi Wang
Junqi Wang
RNRobert Nidetz
Robert Nidetz
SBSanketh Buggaveeti
Sanketh Buggaveeti
EZEdward T. Zellers
Edward T. Zellers

1 January 2016 in Procedia Engineering
Verified
Journal Article
Open access
JWJunqi Wang
Junqi Wang
NNN. Nuñovero
N. Nuñovero
ZLZ. Lin
Z. Lin
RNR. Nidetz
R. Nidetz
SBS. Buggaveeti
S. Buggaveeti
EZE.T. Zellers
E.T. Zellers

16 August 2017 in Proceedings
Verified
Conference Paper
Open access
PDF file
JWJunqi Wang
Junqi Wang
NNNicolas Nuñovero
Nicolas Nuñovero
CZChanghua Zhan
Changhua Zhan
RNRobert Nidetz
Robert Nidetz
WSWilliam H. Steinecker
William H. Steinecker
EZEdward Zellers
Edward Zellers
The capability to analyze complex mixtures of airborne volatile organic compounds (VOCs) at low concentrations; in situ; has implications for environmental monitoring; worker exposure assessment; biomedical diagnostics; and population security. Since standalone microsensor arrays lack this capability; upstream separation of mixture components; often preceded by preconcentration; is required. Although significant advances have been made via MEMS technologies in the development of microscale gas chromatographic (μGC) systems; many challenges remain. This presentation will review selected aspects of the state-of-the-art in μGC for VOC mixture analysis. Here; we emphasize our progress toward a wearable μGC prototype.