Due to the resistance of some bacteria to antibiotics, research in the field of dealing with bacterial infections is necessary. A practical approach utilized in this study involves the preparation of an antibacterial thin film on the surfaces, which can effectively inhibit and reduce biofilm formation and bacterial adherence. In this study, we report the fabrication of bactericidal titanium (Ti) and copper (Cu) surfaces which involves a powerful co-sputtering method. This method provides a situation in which constituent elements are deposited simultaneously to control the composition of the thin film. Prepared samples were examined by energy-dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), X-ray diffraction (XRD), atomic force microscopy (AFM), and contact angle measurements. To evaluate antibacterial behavior, we used two bacterial strains Gram-negative Escherichia coli (E. coli) and Gram-positive Staphylococcus aureus (S. aureus). Antibacterial activity of the prepared sample was assessed by determining the number of colony-forming units per milliliter (CFU/ml) using a standard viable cell count assay. Results indicated that as the Cu concentration increased, the nanoscale surfaces became rougher, with roughness values rising from 11.85 to 49.65 nm, and the contact angle increased from 40 to 80 degrees, indicating a hydrophilic character. These factors play a significant role in the antibacterial properties of the surface. The Ti-Cu films displayed superior antibacterial ability, with a 99.9% reduction (equivalent to a 5-log reduction) in bacterial viability after 2 h compared to Ti alone against both bacterial strains. Field emission scanning electron microscopy (FE-SEM) images verified that both E. coli and S. aureus cells were physically deformed and damaged the bacterial cell ultrastructure was observed. These findings highlight that adding Cu to Ti can improve the antibacterial ability of the surface while inhibiting bacterial adherence. Therefore, the Ti14-Cu86 sample with the highest percentage of Cu had the best bactericidal rate. Investigation of toxicity of Cu-Ti thin films was conducted the using the MTT assay, which revealed their biocompatibility and absence of cytotoxicity, further confirming their potential as promising biomaterials for various applications.
The increasing need for electrode materials exhibiting improved performance to meet the requirements of supercapacitors is on the rise. Hybrid electrodes, which combine reduced graphene oxide (rGO) with transition metal-based oxides, have emerged as promising materials due to their impressive specific capacitance and cost-effectiveness, attributed to their synergistic properties. In the present study, a binder-free CoOrGO composite electrode was synthesized using a facile, fast, and simple one-step co-precipitation method. This was done to improve both capacity and stability for supercapacitor applications. The composite materials underwent comprehensive characterization utilizing various surface analytical techniques, including X-ray diffraction (XRD), energy-dispersive X-ray spectroscopy (EDS), field-emission scanning electron microscopy (FE-SEM), fourier-transform infrared spectroscopy (FTIR), and Brunauer–Emmett–Teller (BET) analysis. Electrochemical measurements of the CoOrGO composite revealed at current density of 2 A cm− 2 a specific capacitance of 132.3 mF cm− 2, with an impressive 95.91% retention of capacitance after 7000 cycles. The results from electrochemical impedance spectroscopy (EIS) highlighted a meager low relaxation time constant of 0.53 s for the composite films. The reason behind this can be linked to the synergistic interactions, and minimal charge transfer resistance exhibited by the porous electrode without binders. Based on the obtained results, this work introduces a flexible methodology for crafting advanced energy storage systems. This demonstrates the potential for designing high-efficiency supercapacitors that are suitable for a broad range of large-scale applications.
Hard coatings are applied in various applications to protect substrates from wear and corrosion. In the present study, multi-element ceramic films are deposited by reactive sputtering. The level of substrate bias voltage (−50, −125 and −200 V) is changed to investigate the structural and mechanical properties of Cr-Nb-Ti-Zr-N thin films. Chemical analysis (using EDS, XRD and Raman spectroscopy) reveals that these thin films (with a high amount of oxygen) are composed of a nanocomposite phase structure (amorphous and nano-crystalline phases). CrO2 and NbxN crystalline phases exist in an amorphous matrix in the coatings. By increasing the substrate voltage (from −50 to −200 V), the nitrogen content (from 30 to 40 at. %) increases, and CrxN crystalline phases are generated in S125 and S200. Morphological, topological and image analysis (employing FESEM and AFM) data show that the intermediate level of substrate bias voltage (sample S125) can produce a uniform surface with minimum defect density (15%). In addition, S125 has the minimum level of roughness (16.6 nm), skewness (0.2) and kurtosis (2.8). Therefore, the hardness, toughness and wear resistance (extracted from indentation and scratch tests) of this sample is maximum (H is 24.5 GPa and H/E is 0.107), while sample S50 shows complete fracture and delamination.