Matthias Militz

Dr. Matthias Militz


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2017 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
SHSven Hungerer
Sven Hungerer
MKMartin Kiechle
Martin Kiechle
Christian von RüdenChristian von Rüden
Christian von Rüden
MMMatthias Militz
Matthias Militz
KBKnut Beitzel
Knut Beitzel
MMMario Morgenstern
Mario Morgenstern
After septic failure of total knee arthroplasty (TKA) and multiple revision operations resulting in impaired function, bone and/or soft-tissue damage a reconstruction with a revision arthroplasty might be impossible. Salvage procedures to regain mobility and quality of life are an above-the-knee amputation or knee arthrodesis. The decision process for the patient and surgeon is difficult and data comparing arthrodesis versus amputation in terms of function and quality of life are scarce. The purpose of this study was to analyse and compare the specific complications, functional outcome and quality of life of above-the-knee amputation (AKA) and modular knee-arthrodesis (MKA) after septic failure of total knee arthroplasty. Eighty-one patients treated with MKA and 32 patients treated with AKA after septic failure of TKA between 2003 and 2012 were included in this cohort study. Demographic data, comorbidities, pathogens and complications such as re-infection, implant-failure or revision surgeries were recorded in 55MKA and 20AKA patients. Functional outcome with use of the Lower-Extremity-Functional-Score (LEFS) and the patients reported general health status (SF-12-questionnaire) was recorded after a mean interval of 55 months. A major complication occurred in more than one-third of the cases after MKA and AKA, whereas recurrence of infection was with 22% after MKA and 35% after AKA the most common complication. Patients with AKA and MKA showed a comparable functional outcome with a mean LEFS score of 37 and 28 respectively (p = 0.181). Correspondingly, a comparable physical quality of life with a mean physical SF-12 of 36 for AKA patients and a mean score of 30 for MKA patients was observed (p = 0.080). Notably, ten AKA patients that could be fitted with a microprocessor-controlled-knee-joint demonstrated with a mean LEFS of 56 a significantly better functional outcome than other amputee patients (p < 0.01) or MKA patients (p < 0.01). Naturally, the decision process for the treatment of desolate situations of septic failures following revision knee arthroplasty is depending on various factors. Nevertheless, the amputation should be considered as an option in patients with a good physical and mental condition.

30 September 2010 in International Journal of Infectious Diseases
Verified
Journal Article
Closed access
PDF file
JFJan Friederichs
Jan Friederichs
SHSven Hungerer
Sven Hungerer
RWRegina Werle
Regina Werle
MMMatthias Militz
Matthias Militz
VBVolker Bühren
Volker Bühren

1 September 2015 in Journal of Infection
Verified
Journal Article
Closed access
JFJan Friederichs
Jan Friederichs
STSebastian Torka
Sebastian Torka
MMMatthias Militz
Matthias Militz
VBVolker Bühren
Volker Bühren
SHSven Hungerer
Sven Hungerer

17 September 2014 in Trauma und Berufskrankheit
Verified
Journal Article
Closed access
PDF file
MMMatthias Militz
Matthias Militz
SHS. Hackl
S. Hackl
SHS. Hungerer
S. Hungerer
MÖM. Öhlbauer
M. Öhlbauer
VBV. Bühren
V. Bühren

13 April 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
FKFlorian Kellermann
Florian Kellermann
Simon HacklSimon Hackl
Simon Hackl
ILIris Leister
Iris Leister
SHSven Hungerer
Sven Hungerer
MMMatthias Militz
Matthias Militz
JFJan Friederichs
Jan Friederichs
Introduction: Surgical site infections after operative stabilization of pelvic and acetabular fractures are rare but serious complications. The treatment of these infections involves additional surgical procedures, high health care costs, a prolonged stay, and often a worse outcome. In this study, we focused on the impact of the different causing bacteria, negative microbiological results with wound closure, and recurrence rates of patients with implant-associated infections after pelvic surgery. Material and Methods: We retrospectively analyzed a study group of 43 patients with microbiologically proven surgical site infections (SSI) after surgery of the pelvic ring or the acetabulum treated in our clinic between 2009 and 2019. Epidemiological data, injury pattern, surgical approach, and microbiological data were analyzed and correlated with long-term follow-up and recurrence of infection. Results: Almost two thirds of the patients presented with polymicrobial infections, with staphylococci being the most common causing agents. An average of 5.7 (±5.4) surgical procedures were performed until definitive wound closure. Negative microbiological swabs at time of wound closure were only achieved in 9 patients (21%). Long-term follow-up revealed a recurrence of infection in only seven patients (16%) with an average interval between revision surgery and recurrence of 4.7 months. There was no significant difference of recurrence rate for the groups of patients with positive/negative microbiology in the last operative revision (71% vs. 78%). A positive trend for a correlation with recurrent infection was only found for patients with a Morel–Lavallée lesion due to run-over injuries (30% vs. 5%). Identified causing bacteria did not influence the outcome and rate of recurrence. Conclusion: Recurrence rates after surgical revision of implant-associated infections of the pelvis and the acetabulum are low and neither the type of causing agent nor the microbiological status at the timepoint of wound closure has a significant impact on the recurrence rate.

19 January 2017 in Der Unfallchirurg
Verified
Journal Article
Closed access
PDF file
MMMatthias Militz
Matthias Militz
WPW. Popp
W. Popp
RHR. Hoffmann
R. Hoffmann
RAR. Ascherl
R. Ascherl
ATA. Tiemann
A. Tiemann