Philippe Gain

Prof. Philippe Gain


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2002 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
PGPhilippe Gain
Philippe Gain
GTG Thuret
G Thuret
CCC Chiquet
C Chiquet
JDJ M Dumollard
J M Dumollard
JMJ F Mosnier
J F Mosnier
LCL Campos
L Campos
Background/aim: It is known that trypan blue staining is not a good predictor of loss of corneal endothelial cells (ECs) during organ culture. As it is primarily an indicator of membrane integrity, it would also not be expected to identify ECs undergoing apoptosis. The aim of this study was to determine the ability of the in situ TdT dUTP mediated nick end labelling (TUNEL) technique to detect cell death in the corneal endothelium caused by apoptosis during organ culture, compared with conventional vital staining with trypan blue. Methods: 31 human corneas were organ cultured at 31°C for 3–35 days. Staurosporine was used to induce apoptosis in five control corneas. The endothelium was assessed by trypan blue and by the in situ TUNEL technique. The percentages of trypan and TUNEL positive ECs were compared. Their links with sex, donor age, time from donor death and organ culture, initial and final EC density and cell loss were studied. Results: TUNEL stained ECs were observed in all corneas. TUNEL positive ECs were mostly located either in corneal folds or at the periphery of corneal folds showing central shedding. The mean percentage of cell death at the end of storage, assessed by the trypan blue technique, was 1.47% (SD 2.63, range 0.03–12); assessed by the TUNEL technique it was 12.7% (SD 16.4 range 0.6–65.5). There was a significant correlation between the two techniques (r = 0.7, p<0.001). The percentage of TUNEL stained ECs was correlated negatively with EC density at the end of storage (r = −0.47, p <0.005) and positively with percentage EC loss during storage (r = 0.46, p < 0.05). Conclusion: This study demonstrates that organ cultured corneas systematically carry non-viable ECs that are implicated in cell death by apoptosis and go undetected when trypan blue staining is used. Because the in situ TUNEL assay detects earlier events in the cell death process than does trypan blue, it should be used to quantify endothelial viability, especially for experiments with new storage media.

1 March 2003 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
GTG Thuret
G Thuret
CCC Chiquet
C Chiquet
SHS Herrag
S Herrag
JDJ-M Dumollard
J-M Dumollard
DBD Boudard
D Boudard
PGPhilippe Gain
Philippe Gain
Background: Apoptosis very probably plays a key part in endothelial cell loss during corneal storage in organ culture as well as hypothermic storage. However, the mechanisms underlying endothelial apoptosis are poorly understood. The response of a human corneal endothelial cell (HCEC) line to staurosporine, a known inducer of apoptosis, was investigated to gain insights into the intracellular modulators that participate in endothelial cell death. Methods: Immortalised HCECs were studied after 3, 6, 12, and 24 hours of incubation with 0.2 μM staurosporine. Cell shedding was monitored. Hoechst 33342 fluorescent DNA staining combined with propidium iodide was used for apoptosis/necrosis quantification and morphological examination. The caspase-3 active form was assessed using western blot, proteolytic activity detection, and immunocytochemistry. The cleaved form of poly(ADP-ribose) polymerase (PARP) was assessed using immunocytochemistry and western blot. The ultrastructural features of cells were screened after 12 hours with staurosporine or vehicle. Results: The specific apoptotic nature of staurosporine induced HCEC death was confirmed. The ultrastructural features of staurosporine treated cells were typical of apoptosis. HCEC shedding and DNA condensation increased with time. Caspase-3 activity was detected as early as 3 hours after exposure with staurosporine, peaking at 12 hours of incubation. The presence of cleaved PARP after 3 hours confirmed caspase-3 activation. Conclusions: These data suggest strongly that HCEC cell death induced by staurosporine is apoptosis. The main consequence of HCEC apoptosis is shedding. Staurosporine induced apoptosis of endothelial cells involves activation of caspase-3, and could be a useful model to study strategies of cell death inhibition.

1 July 2002 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
PGPhilippe Gain
Philippe Gain
GTG Thuret
G Thuret
LKL Kodjikian
L Kodjikian
YGYann Gavet
Yann Gavet
PTP H Turc
P H Turc
LCL Campos
L Campos
Background: Endothelial examination of organ culture stored corneas is usually done manually and on several mosaic zones. Some banks use an image analyser that takes account of only one zone. This method is restricted by image quality, and may be inaccurate if endothelial cell density (ECD) within the mosaic is not homogeneous. The authors have developed an analyser that has tools for automatic error detection and correction, and can measure ECD and perform morphometry on multiple zones of three images of the endothelial mosaic. Methods: 60 human corneas were divided into two equal groups: group 1 with homogeneous mosaics, group 2 with heterogeneous ones. Three standard microscopy video images of the endothelium, graded by quality, were analysed either in isolation (so called mono-image analysis) or simultaneously (so called tri-image analysis), with 50 or 300 endothelial cells (ECs) counted. The automated analysis was compared with the manual analysis, which concerned 10 non-adjacent zones and about 300 cells. For each analysis method, failures and durations were studied according to image quality. Results: All corneas were able to undergo analysis, in about 2 or 7.5 minutes for 50 and 300 ECs respectively. The tri-image analysis did not increase analysis time and never failed, even with mediocre images. The tri-image analysis of 300 ECs was always most highly correlated with the manual count, particularly in the heterogeneous cornea group (r=0.94, p<0.001) and prevented serious count errors. Conclusions: This analyser allows reliable and rapid analysis of ECD, even for heterogeneous endothelia mosaics and mediocre images.

1 April 2002 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
PGPhilippe Gain
Philippe Gain
GTG Thuret
G Thuret
CCC Chiquet
C Chiquet
PRP Rizzi
P Rizzi
JPJ L Pugniet
J L Pugniet
JMJ Maugery
J Maugery
Aim: To study the suitability of corneas from very old donors for graft after banking and their clinical and endothelial outcomes in recipients. Methods: 419 corneas stored in organ culture were divided into group 1, donors under 85 years (330 corneas) and group 2, “very old” donors aged 85 years and over (89 corneas). Endothelial cell density (ECD) before and after organ culture, discard rate before and after storage, and clinical and endothelial outcomes of the 196 penetrating keratoplasties (PKP) (158 in group 1 and 38 in group 2) were compared in a prospective longitudinal study. Results: Initial ECD was lower in group 2 than in group 1 and elimination for low ECD was more frequent in group 2 (respectively 38% v 20.2%, p=0.001). At the end of storage, because very old corneas lost fewer ECs than younger ones (respectively 4.2% v 9.5%, p=0.022), ECD was comparable between the two groups. The corneas of very old donors had a poorer macroscopic appearance at procurement and during surgery. Despite this, in grafted patients, overall graft survival in groups 1 and 2 (respectively 87.4% v 80.6%, p=0.197), visual acuity, and ECD did not differ at completion of the study (mean follow up 25 months). Conclusion: This study suggests that endothelial cell count during banking ensures that functional and cellular results of PKPs are not dramatically influenced by very old donor age. Considering Europe's ageing population, the very elderly should not be deemed off limits for corneal procurement.

1 December 2002 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
GTG Thuret
G Thuret
ACA Carricajo
A Carricajo
CCC Chiquet
C Chiquet
AVA C Vautrin
A C Vautrin
NCN Celle
N Celle
PGPhilippe Gain
Philippe Gain
Aims: To test the bactericidal activity of standard organ culture medium, and to compare the sensitivity and rapidity of blood culture bottles with conventional microbiological methods for detection of bacteria and fungi inoculated in a standard cornea organ culture medium. Methods: The bactericidal activity of contaminated standard organ culture medium containing 100 IU/ml penicillin, 0.1 mg/ml streptomycin, and 0.25 μg/ml amphotericin B was evaluated after 48 hours of incubation at 31°C with five inocula of 14 bacteria. Two yeasts (Candida spp) and one Aspergillus were also tested. Contaminated media were then inoculated in three blood bottles (aerobic, anaerobic, fungal) placed in a Bactec 9240 automat; three conventional microbiological broths were the control. Changes in colour of organ culture medium and growth on conventional broth were screened daily by visual inspection. The sensitivity and rapidity of detection of contamination were compared between the three methods: blood bottle, conventional, and visual. Results: Organ culture medium eradicated five bacteria irrespective of the starting inoculums: Streptococcus pneumoniae, Branhamella catarrhalis, Escherichia coli, Propionibacterium acnes, and Haemophilus influenzae. For micro-organisms where the medium was ineffective or bactericidal only (methicillin resistant Staphylococcus aureus, methicillin sensitive Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus haemolyticus, Pseudomonas aeruginosa, Acinetobacter baumannii, Bacillus subtilis, Klebsiella pneumoniae, Enterococcus faecalis, Candida albicans, Candida kruzei, Aspergillus fumigatus), the blood bottle, conventional, and visual methods detected microbial growth in 100%, 76.5%, and 70% of cases respectively. Mean detection time using blood bottles was 15.1 hours (SD 13.8, range 2–52). In cases of detection by the blood bottle method and the conventional method, the former was always faster: 95.5% against 65.2% detection within 24 hours (p=0.022) respectively. Conclusions: Blood bottles detect more efficiently and more rapidly a wider range of bacteria and fungi than the conventional microbiological method and the visual inspection of organ culture media.

1 October 2001 in British Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
PGPhilippe Gain
Philippe Gain
GTGilles Thuret
Gilles Thuret
CCChristophe Chiquet
Christophe Chiquet
AVAnne-Catherine Vautrin
Anne-Catherine Vautrin
ACAnne Carricajo
Anne Carricajo
GAGérald Aubert
Gérald Aubert
AIMS To test the effectiveness and rapidity of a pair of blood culture bottles in the diagnosis of bacterial and fungal contamination of corneal organ culture media. METHODS 761 microbiological analyses of storage media (Inosol and Exosol, Opsia, Toulouse, France), sampled in all phases of the organ culture at 31°C of 410 consecutive corneas, were analysed. Each medium was inoculated in a pair of Bactec Plus Aerobic/F and Bactec Lytic/10 Anaerobic/F blood bottles and placed in a Bactec 9240 incubator for 14 days at 37°C and in a Sabouraud broth at 20°C. Changes in colour or turbidity of storage media were evaluated daily at the corneal bank. Recipients were screened post-graft for infectious signs. RESULTS Overall contamination rate was 2.4% (18/761). Contamination was detected in less than 1 day in 78% (14/18) and less than 2 days in 94% (17/18). Positivity of the microbiological controls of starting media preceded changes medium colour in 10 out of 14 cases. Bactec blood bottles allowed detection of bacteria as well as yeasts. CONCLUSION The use of a pair of Bactec blood culture bottles appears reliable for the rapid diagnosis of a wide range of microbiological contaminations of organ cultured corneas during banking.