Yasin Cagatay Duygu

Mr. Yasin Cagatay Duygu

Mechanical Engineering, Southern Methodist University, Dallas, Georgia, USA
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 June 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
GKGokhan Kararsiz
Gokhan Kararsiz
YDYasin Cagatay Duygu
Yasin Cagatay Duygu
ZWZhengguang Wang
Zhengguang Wang
LRLouis William Rogowski
Louis William Rogowski
SPSung Jea Park
Sung Jea Park
MinJun KimMinJun Kim
MinJun Kim
This study investigates the motion characteristics of soft alginate microrobots in complex fluidic environments utilizing wireless magnetic fields for actuation. The aim is to explore the diverse motion modes that arise due to shear forces in viscoelastic fluids by employing snowman-shaped microrobots. Polyacrylamide (PAA), a water-soluble polymer, is used to create a dynamic environment with non-Newtonian fluid properties. Microrobots are fabricated via an extrusion-based microcentrifugal droplet method, successfully demonstrating the feasibility of both wiggling and tumbling motions. Specifically, the wiggling motion primarily results from the interplay between the viscoelastic fluid environment and the microrobots’ non-uniform magnetization. Furthermore, it is discovered that the viscoelasticity properties of the fluid influence the motion behavior of the microrobots, leading to non-uniform behavior in complex environments for microrobot swarms. Through velocity analysis, valuable insights into the relationship between applied magnetic fields and motion characteristics are obtained, facilitating a more realistic understanding of surface locomotion for targeted drug delivery purposes while accounting for swarm dynamics and non-uniform behavior.

12 November 2023 in Advanced Intelligent Systems
Verified
Journal Article
Open access
YDYasin Cagatay Duygu
Yasin Cagatay Duygu
UCU Kei Cheang
U Kei Cheang
ALAlexander M. Leshansky
Alexander M. Leshansky
MinJun KimMinJun Kim
MinJun Kim
Planar magnetic microswimmers bear great potential for in vivo biomedical applications as they can be mass‐produced at minimal costs using standard photolithography techniques. Therefore, it is central to understand how to control their motion. This study examines the propulsion of planar V‐shaped microswimmers in an aqueous solution powered by a conically rotating magnetic field and compares the experimental results with theory. Propulsion is investigated upon altering the cone angle of the driving field. It is shown that a V‐shaped microswimmer magnetized along its symmetry axis exhibits unidirectional in‐sync propulsion with a constant (frequency‐independent) velocity in a limited band of actuation frequencies. It is also demonstrated that the motion of individual and multiple in‐plane magnetized planar microswimmers in a conically rotating field can be efficiently controlled.

26 June 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
GKGokhan Kararsiz
Gokhan Kararsiz
YDYasin Cagatay Duygu
Yasin Cagatay Duygu
LRLouis William Rogowski
Louis William Rogowski
ABAnuruddha Bhattacharjee
Anuruddha Bhattacharjee
MinJun KimMinJun Kim
MinJun Kim
This paper demonstrates a manipulation of snowman-shaped soft microrobots under a uniform rotating magnetic field. Each microsnowman robot consists of two biocompatible alginate microspheres with embedded magnetic nanoparticles. The soft microsnowmen were fabricated using a microfluidic device by following a centrifuge-based microfluidic droplet method. Under a uniform rotating magnetic field, the microsnowmen were rolled on the substrate surface, and the velocity response for increasing magnetic field frequencies was analyzed. Then, a microsnowman was rolled to follow different paths, which demonstrated directional controllability of the microrobot. Moreover, swarms of microsnowmen and single alginate microrobots were manipulated under the rotating magnetic field, and their velocity responses were analyzed for comparison.

3 December 2024 in Nanotechnology and Precision Engineering
Verified
Journal Article
Open access
PDF file
YDYasin Cagatay Duygu
Yasin Cagatay Duygu
BXBaijun Xie
Baijun Xie
XZXiao Zhang
Xiao Zhang
MinJun KimMinJun Kim
MinJun Kim
CPChung Hyuk Park
Chung Hyuk Park
Microrobots powered by an external magnetic field could be used for sophisticated medical applications such as cell treatment, micromanipulation, and noninvasive surgery inside the body. Untethered microrobot applications can benefit from haptic technology and telecommunication, enabling telemedical micro-manipulation. Users can manipulate the microrobots with haptic feedback by interacting with the robot operating system remotely in such applications. Artificially created haptic forces based on wirelessly transmitted data and model-based guidance can aid human operators with haptic sensations while manipulating microrobots. The system presented here includes a haptic device and a magnetic tweezer system linked together using a network-based teleoperation method with motion models in fluids. The magnetic microrobots can be controlled remotely, and the haptic interactions with the remote environment can be felt in real time. A time-domain passivity controller is applied to overcome network delay and ensure stability of communication. This study develops and tests a motion model for microrobots and evaluates two image-based 3D tracking algorithms to improve tracking accuracy in various Newtonian fluids. Additionally, it demonstrates that microrobots can group together to transport multiple larger objects, move through microfluidic channels for detailed tasks, and use a novel method for disassembly, greatly expanding their range of use in microscale operations. Remote medical treatment in multiple locations, remote delivery of medication without the need for physical penetration of the skin, and remotely controlled cell manipulations are some of the possible uses of the proposed technology.

17 May 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
GKGokhan Kararsiz
Gokhan Kararsiz
YDYasin Cagatay Duygu
Yasin Cagatay Duygu
ZWZhengguang Wang
Zhengguang Wang
LRLouis William Rogowski
Louis William Rogowski
SPSung Jea Park
Sung Jea Park
MinJun KimMinJun Kim
MinJun Kim
In this study, the motion characteristics of soft alginate microrobots were investigated with wireless magnetic fields in complex fluidic environments. Our aim is to explore the various motion modes that arise as a result of shear forces in viscoelastic fluids. Polyacrylamide (PAA), a water-soluble polymer, was characterized to produce a dynamic environment with a non-Newtonian fluid. The robots were fabricated by an extrusion-based microcentrifugal droplet method. We successfully demonstrated the feasibility of both wiggling and tumbling motions using snowman-shaped microbots. It is found that wiggling motion is primarily influenced by the interaction between the viscoelastic fluid environment and the non-uniform magnetization of the microbots. Additionally, it is discovered that modifying the viscoelasticity properties of the fluid can affect the motion behavior of the microbots. Furthermore, we observed that swarms of microbots exhibit non-uniform behavior within complex environments. Our velocity analysis has provided valuable insights into the relationship between applied magnetic fields and motion characteristics, enabling a more realistic understanding of surface locomotion in the context of targeted drug delivery.

9 December 2025 in IEEE Access
Verified
Journal Article
Open access
SLSangwon Lee
Sangwon Lee
MAMuhammad I. Azeez
Muhammad I. Azeez
YDYasin Cagatay Duygu
Yasin Cagatay Duygu
MinJun KimMinJun Kim
MinJun Kim
This paper presents a triaxial Helmholtz coil instrument that generates position-independent magnetic gradients for microrobot force actuation without auxiliary Maxwell coils. By independent driving six coils with asymmetric current pairs, the system decouples the three Cartesian force components. We derive a fixed actuation matrix that maps coil currents to magnetic field and gradient, via COMSOL-assisted modeling combined with in situ triaxial-magnetometer calibration. Simulation and experimental measurements show 99% agreement across a 40×40×40 mm3 workspace, confirming near-uniform gradients without any position-dependent look-up table. This fixed-matrix approach is particularly useful when real-time vision-based feedback is intermittent or unavailable (e.g., ocular surgery or combat-related injuries with opacity or bleeding). To address ill-conditioning and current limits, we consider Tikhonov regularization (TR) and truncated space vector decomposition (TSVD) for current allocation. We further validate gradient control by demonstrating open-loop three-dimensional microrobot translations in viscous media. Overall, the proposed system provides a compact, cost-effective, metrology-ground framework for gradient-based magnetic manipulation using a Helmholtz architecture.