22 July 2020 in Science Translational Medicine
Optogenetic hearing restoration in rodents by LED-based multichannel optical cochlear implants provides improved spectral selectivity.
25 August 2010 in IEEJ Transactions on Electrical and Electronic Engineering
Extracellular recordings from the brain are the basis for the fundamental understanding of the complex interaction of electrical signals in neural information transfer. Going beyond wire electrodes and bundles of electrode wires such as tetrodes, multielectrode arrays based on silicon technologies are receiving growing attention, since they enable a pronounced increase in the number of recording sites per probe shaft. In this paper, recent innovations contributed by the authors to the development of probe arrays based on microelectromechanical system (MEMS) technologies within the EU‐funded research projectNeuroProbesare described. The resulting structures include passive electrode arrays based on single‐shaft and four‐shaft probes comprising nine planar electrodes per shaft with lengths of up to 8 mm. Further, active probe arrays with complementary metal–oxide–semiconductor (CMOS) circuitry integrated on the probe shaft, enabling the arrangement of 188 electrodes in two columns along a 4‐mm‐long probe shaft with an electrode pitch of only 40 µm, are described. These active probes were developed for an electronic depth control. Further, the paper reports assembly technologies for combining the probe arrays with highly flexible ribbon cables. Applications of the probes inin vivoexperiments are summarized. © 2010 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
29 June 2020 in EMBO Molecular Medicine
Electrical cochlear implants (eCIs) partially restore hearing and enable speech comprehension to more than half a million users, thereby re‐connecting deaf patients to the auditory scene surrounding them. Yet, eCIs suffer from limited spectral selectivity, resulting from current spread around each electrode contact and causing poor speech recognition in the presence of background noise. Optogenetic stimulation of the auditory nerve might overcome this limitation as light can be conveniently confined in space. Here, we combined virus‐mediated optogenetic manipulation of cochlear spiral ganglion neurons (SGNs) and microsystems engineering to establish acute multi‐channel optical cochlear implant (oCI) stimulation in adult Mongolian gerbils. oCIs based on 16 microscale thin‐film light‐emitting diodes (μLEDs) evoked tonotopic activation of the auditory pathway with high spectral selectivity and modest power requirements in hearing and deaf gerbils. These results prove the feasibility of μLED‐based oCIs for spectrally selective activation of the auditory nerve.
11 August 2020 in Applied Physics Express
1 April 2016 in Sensors and Actuators A: Physical
19 October 2018 in Journal of Microelectromechanical Systems
This paper reports on the development, characterization, and validation of neural probes serving the growing needs of neuroscience for miniaturized tools enabling simultaneous high-resolution recording of neural activity in multiple brain areas. The probes consist of a needle-shaped shaft with a cross-section of 100x 50,μm² and a length of 10 or 5 mm emerging from a base with dimensions of only 0.55x 1.8 mm². The shafts carry 1600 and 800 recording sites, respectively, grouped into 50 (respectively 25) blocks of 4x 8 electrodes with an area of 17x 17,μm² each, a pitch of 20 μm, and an electrode-to-electrode spacing of 3 μm. The probes are fabricated using a commercial 0.18 μm CMOS process followed by dedicated metallization, passivation, and microfabrication steps. Neural signals are accessible through 32 analog output channels via a hierarchical digital addressing scheme implementing an advanced electronic depth control concept giving the option of multiple scanning modes and offering a switching time of 416 μs at a clock frequency of 1 MHz. All output channels are shielded against each other, whereby crosstalk between neighboring channels is measured to be -58 dB at 1 kHz. Absolute impedance values at 1 kHz of single IrOₓ and Pt electrodes are 230± 38 kΩ and 2.2± 0.3 MΩ, respectively. In vivo recordings taking advantage of the new addressing concept for high-resolution recordings from multiple brain regions were successfully performed in anesthetized rats. [2018-0152]