Mohammad Hasan Shahriari

Dr. Mohammad Hasan Shahriari

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Frontiers in Health Informatics
Verified
Journal Article
Open access
PDF file
ENElham Nazari
Elham Nazari
MSMohammad Hasan Shahriari
Mohammad Hasan Shahriari
HTHamed Tabesh
Hamed Tabesh
Introduction: Health care data is increasing. The correct analysis of such data will improve the quality of care and reduce costs. This kind of data has certain features such as high volume, variety, high-speed production, etc. It makes it impossible to analyze with ordinary hardware and software platforms. Choosing the right platform for managing this kind of data is very important. The purpose of this study is to introduce and compare the most popular and most widely used platform for processing big data, Apache Hadoop MapReduce, and the two Apache Spark and Apache Flink platforms, which have recently been featured with great prominence.Material and Methods: This study is a survey whose content is based on the subject matter search of the Proquest, PubMed, Google Scholar, Science Direct, Scopus, IranMedex, Irandoc, Magiran, ParsMedline and Scientific Information Database (SID) databases, as well as Web reviews, specialized books with related keywords and standard. Finally, 80 articles related to the subject of the study were reviewed.Results: The findings showed that each of the studied platforms has features, such as data processing, support for different languages, processing speed, computational model, memory management, optimization, delay, error tolerance, scalability, performance, compatibility, Security and so on. Overall, the findings showed that the Apache Hadoop environment has simplicity, error detection, and scalability management based on clusters, but because its processing is based on batch processing, it works for slow complex analyzes and does not support flow processing, Apache Spark is also distributed as a computational platform that can process a big data set in memory with a very fast response time, the Apache Flink allows users to store data in memory and load them multiple times and provide a complex Fault Tolerance mechanism Continuously retrieves data flow status.Conclusion: The application of big data analysis and processing platforms varies according to the needs. In other words, it can be said that each technology is complementary, each of which is applicable in a particular field and cannot be separated from one another and depending on the purpose and the expected expectation, and the platform must be selected for analysis or whether custom tools are designed on these platforms.

21 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
SNSana Niazi
Sana Niazi
MGMarta Jiménez García
Marta Jiménez García
OFOliver Findl
Oliver Findl
ZGZisis Gkatzioufas
Zisis Gkatzioufas
FDFarideh Doroodgar
Farideh Doroodgar
MJMohammad Ali Javadi
Mohammad Ali Javadi
The remarkable recent advances in managing keratoconus, the most common corneal ectasia, encouraged researchers to conduct further studies on the disease. Despite the abundance of information about keratoconus, debates persist regarding the detection of mild cases. Early detection plays a crucial role in facilitating less invasive treatments. This review encompasses corneal data ranging from the basic sciences to the application of artificial intelligence in keratoconus patients. Diagnostic systems utilize automated decision trees, support vector machines, and various types of neural networks, incorporating input from various corneal imaging equipment. Although the integration of artificial intelligence techniques into corneal imaging devices may take time, their popularity in clinical practice is increasing. Most of the studies reviewed herein demonstrate a high discriminatory power between normal and keratoconus cases, with a relatively lower discriminatory power for subclinical keratoconus.

27 June 2025 in Experimental Eye Research
Verified
Journal Article
Closed access
ZRZhale Rajavi
Zhale Rajavi
FHFirouze Hatami
Firouze Hatami
SMSina Khosravi Mirzaei
Sina Khosravi Mirzaei
MLMohammed Lateef
Mohammed Lateef
ZKZahra Khorrami
Zahra Khorrami
HSHamideh Sabbaghi
Hamideh Sabbaghi

21 January 2025 in BMC Research Notes
Verified
Journal Article
Open access
PDF file
MYMaryam Yadgari
Maryam Yadgari
MKMasomeh Kalantarion
Masomeh Kalantarion
MSMohammad-Mehdi Sadoughi
Mohammad-Mehdi Sadoughi
SASoleiman Ahmady
Soleiman Ahmady
MSMohammad Hasan Shahriari
Mohammad Hasan Shahriari
Glaucoma is a major cause of irreversible blindness globally. Optical coherence tomography (OCT) aids early glaucoma diagnosis. Interpreting OCT scans requires familiarity with the technology and image analysis. This study aimed to evaluate the effects of a mobile flipped classroom model on learning outcomes and satisfaction for teaching optical coherence tomography (OCT) interpretation skills in glaucoma. In this quasi-experimental pre/post-test study, a total of 22 ophthalmology residents participated in a 4-session mobile flipped classroom educational intervention (90 min/session) and were assessed on OCT interpretation. Learning was measured via pre/post-tests designed by a panel. Satisfaction was assessed using a validated questionnaire. Mean participant age was 29.42 (± 2.09) years. Compared to pre-intervention, post-test scores showed significant improvement after the mobile flipped classroom (p < 0.001). Mean satisfaction score was 74.05 (± 16.09), denoting high satisfaction. Implementing a mobile flipped classroom significantly improved OCT interpretation skills and was associated with high satisfaction ratings among ophthalmology residents. This model shows promise for enhancing clinical knowledge in graduate medical education.

17 December 2025 in British Journal of Ophthalmology
Verified
Journal Article
Closed access
SFSepehr Feizi
Sepehr Feizi
FHFirouze Hatami
Firouze Hatami
SMSina Khosravi Mirzaei
Sina Khosravi Mirzaei
MSMohammad Hasan Shahriari
Mohammad Hasan Shahriari
MDMohammad Reza Dolikhani
Mohammad Reza Dolikhani
HEHamed Esfandiari
Hamed Esfandiari
Background/aims: Developing high-quality multiple-choice questions (MCQs) for medical education is a challenging and time-consuming task. This study aimed to assess the applicability of Chat Generative Pre-trained Transformer (ChatGPT) in generating MCQs for ophthalmology residents. Methods: ChatGPT 4 was used to generate 100 MCQs, while an additional 100 MCQs were authored by university faculty. Item-writing flaws in both sets of questions were evaluated by a single reviewer. A quality assessment panel, consisting of board-certified ophthalmology subspecialists, compared the quality of two sets. Ophthalmology residents then answered all MCQs in a randomised order. The item difficulty and discrimination indices were calculated and compared between the two sets of questions. Results: Item-writing flaws were more frequent in ChatGPT-generated MCQs (56%) compared with human-authored MCQs (27%, p<0.001). While ChatGPT-generated questions were comparable to human-written ones in most quality parameters, the distractor quality was significantly higher in human-generated MCQs (p=0.006). The mean resident scores were 46.5±9.5 for the ChatGPT-generated MCQs and 49.0±10.9 for the human-written MCQs (p=0.051). The difficulty index was 0.47±0.21 and 0.51±0.19, respectively (p=0.12). The discrimination index was significantly lower in the ChatGPT questions (0.20±0.19 vs 0.28±0.16, p<0.001). Conclusions: While ChatGPT can efficiently generate MCQs for ophthalmology residents, it has notable limitations, including higher rates of item-writing flaws and lower-quality distractors. Additionally, ChatGPT-generated MCQs are less effective at distinguishing high-performing from low-performing examinees. Integrating ChatGPT with human expertise is essential to enhance the quality and reliability of artificial intelligence-generated MCQs.

29 August 2025 in Current Eye Research
Verified
Journal Article
Closed access
MFMohadeseh Feizi
Mohadeseh Feizi
SJShohreh Jafari
Shohreh Jafari
RNRamin Nourinia
Ramin Nourinia
NMNastaran Mahmoudnejad
Nastaran Mahmoudnejad
ANAmirhossein Nayebzadeh
Amirhossein Nayebzadeh
AVAmirreza Veisi
Amirreza Veisi
To investigate the short and long-term effects of Tadalafil on macular and peri-optic disc choroidal thickness, retinal vascular density, and GCC thickness in patients with erectile dysfunction. Patients with erectile dysfunction who were candidates to treat with 10 mg of Tadalafil every other day and didn't use any type of phosphodiesterase 5 inhibitors (PDE5I) in the previous 6 months and had normal eye exams were included. Macular and peri-optic disc choroidal thickness, superficial and deep retinal vascular density, and Macular Ganglion Cell Complex (GCC) thickness were measured before (baseline), one day, and 3 months after Tadalafil treatment. The measurements before and after treatment were compared. Thirty-one eyes of 16 patients with a mean age of 53.7 (42 to 68) years were included. After Tadalafil consumption, the choroidal thickness in the sub-macular (13.8%) and peri-optic disc (14.9%) area and also the vascular density of superficial (9.6%) and deep (9.8%) retinal capillary plexus was increased on the first day. After 3 months, we found a decremental pattern in all initially increased parameters, although sub-macular and peri-papillary choroidal thickness are yet thicker than the baseline. The retinal ganglion cell complex (GCC) average thickness was not significantly changed, neither on the first day nor after three months. Tadalafil can increase the retinal vascular density and choroidal thickness early after initial consumption but after 3 months the initial increment tend to decrease.